background image

4

FAAC Model 770 Underground Swing Gate Operator

Gate Construction

Vehicular gates should be constructed and installed 

in accordance with ASTM F2200: Standard Specifica

-

tion for Automated Vehicular Gate Construction. 

For more information, contact ASTM at: 

www.astm.org

Installation

• 

If you have any questions or concerns regarding the 

safety of the gate operating system, do not install the 

operator and consult the manufacturer. 

• 

The condition of the gate structure itself directly 

affects the reliability and safety of the gate operator.

• 

Only qualified personnel should install this equipment. 

Failure to meet this requirement could cause severe 

injury and/or death, for which the manufacturer 

cannot be held responsible.

• 

The installer must provide a main power switch that 

meets all applicable safety regulations.

• 

It is extremely unsafe to compensate for a damaged 

gate by increasing hydraulic pressure.

• 

Install devices such as reversing edges and photo 

beams to provide better protection for personal 

property and pedestrians. Install reversing devices 

that are appropriate to the gate design and 

application.

• 

Before applying electrical power, ensure that voltage 

requirements of the equipment correspond to the 

supply voltage. Refer to the label on your gate 

operator system.

Usage

• 

Use this equipment only in the capacity for which it 

was designed. Any use other than that stated should 

be considered improper and therefore dangerous.

• 

The manufacturer cannot be held responsible 

for damage caused by improper, erroneous or 

unreasonable use. 

• 

If a gate system component malfunctions, disconnect 

the main power before attempting to repair it.

• 

Do not impede the movement of the gate, you may 

injure yourself or damage the gate system as a result.

• 

This equipment may reach high thermal temperatures 

during normal operation, therefore use caution when 

touching the external housing of the gate operator.

• 

Use the manual release mechanism according to the 

procedures presented in this manual.

• 

Before performing any cleaning or maintenance 

operations, disconnect power to the equipment.

• 

All cleaning, maintenance or repair work must 

performed by qualified personnel.

General Safety Precautions

9.  For gate operators that utilize a contact sensor (edge 

sensor or similar): 

• 

Locate one or more contact sensors where the risk 

of entrapment or obstruction exists, such as at the 

leading edge, trailing edge, and post mounted both 

inside and outside of a vehicular horizontal slide 

gate

• 

Locate one or more contact sensors at the bottom 

edge of a vehicular vertical lift gate.

• 

Locate one or more contact sensors at the bottom 

edge of a vertical barrier (arm).

• 

Locate one or more contact sensors at the pinch 

point of a vehicular vertical pivot gate.

• 

Locate hard-wired contact sensors and wiring so 

that communication between sensor and gate 

operator is not subjected to mechanical damage.

• 

Locate wireless contact sensors, such as those 

that transmit radio frequency (RF) signals, where 

the transmission of signals are not obstructed or 

impeded by building structures, natural landscaping 

or similar hindrances. Wireless contact sensors shall 

function under their intended end-use conditions.

• 

Use only FAAC MSE MO, CN60 or M60 edge 

sensors.

Important Installation Instructions (continued)

Summary of Contents for 770 COMPACT

Page 1: ...onal Inc Headquarter East Coast Operations 5151 Sunbeam Road Suites 9 11 Jacksonville FL 32257 Tel 866 925 3222 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia Avenue Uni...

Page 2: ...tion Instructions 3 General Safety Precautions 4 UL325 Gate Operator Classifications 5 Installing the Warning Signs 5 1 DESCRIPTION CHARACTERISTICS 6 2 STANDARD INSTALLATION LAYOUT 6 3 INSTALLING THE...

Page 3: ...r Reset buttons must be located within line of sight of the gate Activation of the reset control shall not cause the operator to start 7 All warning signs and placards must be installed and easily see...

Page 4: ...easonable use If a gate system component malfunctions disconnect the main power before attempting to repair it Do not impede the movement of the gate you may injure yourself or damage the gate system...

Page 5: ...dings such as factories loading docks or other locations not intended to service the general public RESTRICTED ACCESS VEHICULAR GATE OPERATOR CLASS IV A vehicular gate operator system intended for use...

Page 6: ...lding has to be done on the gate complete it before installing the automation system Fig 1 2 STANDARD INSTALLATION LAYOUT Fig 2 3 2 INSTALLING THE LEAF SUPPORTING FOUNDATION BOX Fig 3 a For Existing G...

Page 7: ...ions provided in Figs 6a and 6b The center of the pivot on the foundation box must be perfectly aligned with the leaf s axis of swing Figs 6a and 6b 3 Lay down a 1 5 inch diameter PVC tube through whi...

Page 8: ...the driving levers supplied as shown in Fig 13 Note grease the operator pinion and the fixing pivots of the two levers 4 Install the second operator if required by repeating the opera tions described...

Page 9: ...til the lock is engaged in the locking bracket Fig 16 Ref 3 4 Close the lid on the lock 7 RETURNING TO NORMAL OPERATION 8 MAINTENANCE Fig 16 9 REPAIRS 1 Program the electronic control unit according t...

Page 10: ...70 1 1 Y 770 24V MOTOR 002 716078 1 1 Y 770 GEAR BOX 004 727158 1 1 Y 770 GEAR BOX COVER 007 718076 1 1 Y SW G O THIRD INTERNAL SHAFT GROUP 008 719165 1 1 Y SW G O 770 INTERNAL SLOW SHAFT 010 390451 0...

Page 11: ...of the product s or has been subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under cond...

Reviews: