background image

770

ENGLISH

Guide for the installer

Page

Thank you for choosing our product. FAAC is sure that it will give you 

all the performances you are looking for. All our products are the 

result of a long experience in the field of the automated systems.

  In the middle of the handbook you will find a detachable 

brochure with the images for the installation.

The 

770

 automation system for swing gates is a geared motor. It is 

designed for underground installation and therefore does not alter 

the appearance of the leaf.

The  foundation  box  of  the  automation  system  comes  ready  to 

take an operator.

The 

770

  electromechanical  operator  is  irreversible,  so  it  ensures 

a mechanical stop and eliminates the need to install an electric 

lock.

IMPORTANT NOTES FOR INSTALLER

Before starting the installation of the operator read this manual 

completely.

Keep this manual for future reference.

Smooth operation and specifications are obtained only declared 

following the directions given in this handbook and with acces-

sories and safety devices FAAC.

The lack of a mechanical clutch device requires to ensure an 

adequate level of security automation, the use of a central control 

device with an electronically controlled clutch.

The automation was designed and built to control vehicular ac-

cess. Avoid any other use.

The operator can not be used to handle emergency exit routes 

or gates installed on emergency (escape routes).

If there is built-in anti motorize from a door to the walkway is requi-

red to add a safety switch on the door, connected on the entry of 

STOP, to inhibit the operation of automation with door open.

Everything  that  is  not  expressly  stated  in  this  manual  is  not  al-

lowed.

1. DESCRIPTION AND TECHNICAL CHARACTERISTICS

1.1. DESCRIPTION (Fig. 1)

Pos.

Description

a

Foundation box

b

Bores for fastening boxcover

c

operator

d

Support bracket for gate

e

Locking bracket

f

Release device with key

g

Crank and connecting rod assembly

h

Pinion

i

Bore for power supply cable pipe

j

Bore for drain pipe

k

Fastening screws for operator

l

Lubrication bore

m

Boxcover

n

Plug of closing 

1.2. TECHNICAL CHARACTERISTICS

Model

770 Lento

770 230V

770 24V

Power supply (Vac) (Vdc)

230

24

Power (W)

300

380

70

Current (A)

1.3

1.7

3

Thermal protection (°C)

140

/

Capacitor (µF)

12.5

/

Max torque (Nm)

250

330

300

Nominal torque (Nm)

170

220

200

Noisiness (dB(A))

< 70

Angular velocity (°/sec)

4

6

6

Door opening angle

110° (140° and 180° with kit)

Max. leaf (m)

3.5 (110°) - 3 (180°) - 2.5 (140°)

Use type and frequency

S3 - 30%

100%

Minimum  indicative  hourly 

cycles

20 (110° e 

180°)

36 (140°)

30 (110° e 

180°)

50 (140°)

100 (110° e 

180°)

170 (140°)

Model

770 Lento

770 230V

770 24V

Operating ambient tempe-

rature (°C)

-20 ÷ +55

Operator weight (Kg)

26.5

Protection class

IP67

Operator dimensions (mm)

360 x 150 x 140

Box dimensions 

See figura 2

2. MAXIMUM USE CURVE

The  curve  makes  it  possible 

to  establish  maximum  work 

time  (T)  according  to  use 

frequency (F).

With  reference  to  IEC  34-1 

standard, the 770 gearmotor 

operating at S3 service, can 

function at a use frequency 

of 30%.

To ensure efficient operation, 

operate  in  the  work  range 

below the curve.

  The  curve  is  obtai-

ned  at  a  temperatu-

re  of  20°C.  Exposure 

to  the  direct  sun  rays 

can  reduce  use  fre-

quency down to 20%. 

C

alCulation

 

of

 

use

 

frequenCy

The percentage of effective work time (o closing) compa-

red to total time of cycle (o c pause times).

Calculation formula:

Ta + Tc

% F =  ––––––––––––––––––– X 100

Ta + Tc + Tp + Ti

where:   

Ta = opening time

Tc =  

closing time

Tp = pause time

Ti =  time of interval between two complete cycles

3. ELECTRIC EQUIPMENT (standard system Fig. 3)

Pos.

Description

Cables

a

Operators  770  (require  2 

junction boxes)

4x1.5mm

2  

(x 24V 2x2.5mm

2

)

b

Photocells TX

2x0.5mm

2

c

Photocells RX

4x0.5mm

2

d

Pushbutton

2x0.5mm

2

e

Flashing light

2x1.5mm

2

f

Control unit

3x1.5mm

2

 

(Supply 230/115V)

  To lay electrical cables, use adequate rigid and/or flexible 

tubes.

  Always separate low voltage accessories from those ope-

rating  at  230  V~.  To  avoid  any  interference,  always  use 

separate sheaths.

4. INSTALLATION OF THE AUTOMATION SYSTEM

4.1. PRELIMINARY CHECKS

To ensure trouble-free operation, make sure that the gate (whether 

existing or yet to be installed) has the following specifications:

max. weight of single leaf 500 Kg;

max. length of single gate leaf 3.5 m with levers for 110° ope-

ning;

max. length of single gate leaf 3 m with levers for 180° opening;

max. length of single gate leaf 2.5 m with levers for 140° ope-

ning;

strong and rigid leaf frame;

Use frequency graph

Use frequency graph

Summary of Contents for 770 230V

Page 1: ...770 ...

Page 2: ...22 23 24 25 26 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 of a torque control Nevertheless its tripping threshold must be checked as specified in the Standards indicated at point 10 The safety devices EN 12978 standard protect any danger areas against mechanical movement Risks such as crushing dragging and shearing Use of at least one indicator light is recommended for every system as well as a warnin...

Page 3: ...ility directive and also declares that it is prohibited to put into service the machinery until the machine in which it will be integrated or of which it will become a component has been identified and declared as conforming to the conditions of Directive 2006 42 EEC and subsequent modifications Bologna December 30 2009 Managing Director A Marcellan Managing Director A Marcellan INDEX IMPORTANT NO...

Page 4: ...l 770 Lento 770 230V 770 24V Power supply Vac Vdc 230 24 Power W 300 380 70 Current A 1 3 1 7 3 Thermal protection C 140 Capacitor µF 12 5 Max torque Nm 250 330 300 Nominal torque Nm 170 220 200 Noisiness dB A 70 Angular velocity sec 4 6 6 Door opening angle 110 140 and 180 with kit Max leaf m 3 5 110 3 180 2 5 140 Use type and frequency S3 30 100 Minimum indicative hourly cycles 20 110 e 180 36 1...

Page 5: ...act position of the operator with the levers for 110 and 140 opening please refer to fig 12 In any case the operator pinion must be on the opposite side of leaves opening direction a b c 1 2 3 4 1 2 3 4 5 1 2 Manually close the leaf and fit the driving levers supplied as shown in Fig 13a In order to determine the exact position of the operator gear plate for 180 opening Fig 13b and the required se...

Page 6: ...g term operation and a constant level of safety we advise you to generally control the system at least every 6 months In the User s Guide booklet there is a form for recording jobs 11 REPAIRS The User must not in any way attempt to repair or to take direct action and must solely contact qualified FAAC personnel or FAAC service centres ...

Page 7: ...770 Immagini Images Images Imágenes Bilder Afbeeldingen Pag Fig 1 Fig 3 Fig 2 Fig 4 Fig 5 Fig 6a Fig 6b ...

Page 8: ...770 Immagini Images Images Imágenes Bilder Afbeeldingen Pag Fig 6c Fig 7 Fig 8 Fig 9 Fig 10a Fig 10b Fig 11 Fig 12 ...

Page 9: ...770 Guida per l utente User s guide Instructions pour l utilisateur Guía para el usuario Anweisungen für den Benutzer Gebruikersgids ...

Page 10: ...on box of the automation system comes ready to take an operator The 770 electromechanical operator is irreversible so it ensures a mechanical stop and eliminates the need to install an electric lock A manual release makes it possible to move the gate in the event of a power cut or fault 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 The operators are supervised by an electronic control unit housed in a conta...

Page 11: ...ung 1 Velligheldsvoorziening 1 Dispositivo di sicurezza 2 Safety device 2 dispositif de sécurité 2 Dispositivo de seguridad 2 Scherhelt svorrichtung 1 Velligheldsvoorziening 2 Coppia di fotocellule 1 Pair of photocells 1 Paire de photocellules 1 Par de fotocélulas 1 Fotozellenpaar 1 Paar fotocellen 1 Coppia di fotocellule 2 Pair of photocells 2 Paire de photocellules 2 Par de fotocélulas 2 Fotozel...

Page 12: ...echnicien Técnico Techniker Technicus Cliente Customer Client Cliente Kunde Klant 4 Tecnico Technicia Technicien Técnico Techniker Technicus Cliente Customer Client Cliente Kunde Klant 5 Tecnico Technicia Technicien Técnico Techniker Technicus Cliente Customer Client Cliente Kunde Klant 6 Tecnico Technicia Technicien Técnico Techniker Technicus Cliente Customer Client Cliente Kunde Klant 7 Tecnico...

Page 13: ...770 Note Notes Note Notas Anmerkung Opmerkingen Page 10 ...

Page 14: ...770 Note Notes Note Notas Anmerkung Opmerkingen Page 11 ...

Page 15: ...ngen in vorliegendem Handbuch sind unverbindlich FAAC behält sich das Recht vor ohne die wesentlichen Eigenschaften dieses Gerätes zu verändern und ohne Verbindlichkeiten in Bezug auf die Neufassung der vorliegenden Anleitungen technisch bzw konstruktiv kommerziell bedingte Verbesserungen vorzu nehmen Las descripciones y las ilustraciones de este manual no comportan compromiso alguno FAAC se reser...

Page 16: ...770 Immagini Images Images Imágenes Bilder Afbeeldingen Pag Fig 13a Fig 13b Fig 14 Fig 15 Fig 16 Fig 17 ...

Page 17: ...ngen in vorliegendem Handbuch sind unverbindlich FAAC behält sich das Recht vor ohne die wesentlichen Eigenschaften dieses Gerätes zu verändern und ohne Verbindlichkeiten in Bezug auf die Neufassung der vorliegenden Anleitungen technisch bzw konstruktiv kommerziell bedingte Verbesserungen vorzu nehmen Las descripciones y las ilustraciones de este manual no comportan compromiso alguno FAAC se reser...

Reviews: