Gate System Parts
Wire Gauges for Given
Power Source Voltage
1
760 Operator in mounting box
220 VAC
2
760 Control Panel box
A
4 X 14 AWG
3
Main power switch
B
3 X 18 AWG
4
Circuit breaker
C
5 X 18 AWG
5
Main junction box
D
5 X 18 AWG
6
Switch for 760 Operator
E
4 X 14 AWG up
7
Switch for 760 Operator
to 414 ft (126 m)
8
Radio receiver
Figure 18. Typical layout of gate system with 760 Operators
Install the 450 MPS
Control Panel
Locate the control panel in a convenient position,
considering the movement of the gate. Figure 7 shows
a basic layout for a two-leaf gate with two 760
Operators.
Installing the control panel consists of the following
general steps:
•
Connect the main power supply
•
Connect the operator(s) to the control panel
•
Check the direction of the motor’s rotation
•
Connect other devices
•
Set operating controls
The installer is responsible for grounding the operator
systems, for providing the main power breaker switch,
and for making sure that the entire gate system meets
all applicable electrical codes.
Follow the instructions that follow to install the 450
MPS control panel for the 760 Operator.
Connect the Main Power Supply
WARNING
! Turn the main power off before you
make any electrical connections or set any switches
inside the control panel box.
Wire the main power supply to control panel terminals
in block J1 (see Figures 20 and 21). The installer is
responsible for insuring that a separate, grounded
circuit protected by a circuit breaker is between the
control panel and the main power supply. All wiring
should conform to applicable electrical codes, and all
wiring and fittings should be weatherproof and/or
suitable for burial.
Connect the ground to the grounding terminal in block
J1 and connect the power wires to the terminals
labeled N (neutral) and L (line).
Caution
: The operators are grounded only by the
grounded circuit the installer provides.
Note:
For a 230v system, a neutral is not needed.
Connect one 115v line to the L (line terminal) and a
second 115v line to the N (neutral terminal).
Locate switches 10 ft from gate