USER’S GUIDE

AUTOMATIC SYSTEMS 525-530

Read the instructions carefully before using the product and store them for future use.

GENERAL SAFETY REGULATIONS

If correctly installed and used, 525-530 automatic systems ensure a high degree of safety.
Some simple rules on behaviour can prevent accidental trouble:
- Do not, under any circumstances,  stand under the overhead door.
- Do not allow children, persons or things near the automatic systems, especially while

they are operating.

- Keep remote-controls, or other pulse generators that could open the door, well away

from children.

- Do not allow children to play with the automatic system.
- Do not willingly obstruct door movement.
- Prevent any branches or shrubs from interfering with door movement.
- Keep the indicator-lights efficient and easy to see.
- Do not attempt to activate the door by hand unless you have released it.
- In the event of malfunctions, release the door to allow access and wait for qualified

technical personnel to do the necessary work.

- When you have set manual operation mode, cut power to the system before restoring

normal operation.

- Do not in any way modify the components of the automation system.
- Do not attempt any kind of repair or direct action whatever and contact qualified

FAAC personnel only.

- At least every six months: arrange a check by qualified personnel of the automatic

system, safety devices and earth connection.

DESCRIPTION

Automatic systems 525-530 are designed to automate overhead spring-balanced,

sectional, counterbalanced (with special GDA 3000 accessory) doors for residential
garages.

The automatic systems consist of an electro-mechanical operator, electronic control

appliance, courtesy lamp and protection housing built into a single unit.

The system is non-reversing and, therefore, the door locks mechanically when the motor

is not operating and, consequently, no other lock is necessary; a manual release makes
it possible to move the door in case of a power cut or fault.

An electronic device ensures that any obstacles are detected.
The door is normally closed; when the electronic control unit receives an opening

command from the remote control, or from any other type of pulse generator (fig.1), it
activates the electric motor which, by means of a transmission chain,  pulls the door
open to allow access.

-If the automatic mode was set, the door closes automatically after pause time has

elapsed.

An opening pulse supplied during opening has no effect.
-If the semi-automatic mode was set,  a second pulse must be sent to close the door

again.

An opening pulse supplied during opening stops movement.
An opening pulse supplied during re-closing, always causes movement to be reversed.
A stop pulse (if supplied) always stops movement.
For full details of door activity in the different logics, consult the installation engineer.
Automatic systems may include safety devices (photocells) that prevent the door from

closing when there is an obstacle in the area they protect.

Emergency manual opening is possible by using the release system.
The warning-light indicates that the door is currently moving.
The courtesy light is activated when the motor  starts and continues for about 2 minutes

after it stops.

MANUAL OPERATION

The 525-530 operators are equipped with an emergency system activated from the inside

– however, a lock can be fitted on request, for activating release from the outside.

If the door has to be moved manually due to a power cut or a fault of the automatic

system, use the release device as follows:

- Release the operator, by pulling the release lever downward (fig.22 ref.A).

 RESTORING AUTOMATIC  OPERATION MODE

Re-lock the automatic system by pulling the handle sideways (fig.2 ref.B):
N.B.: on release, make sure you can see the red “LOCK” indication window under the
carriage – this means it was correctly reset.
Important: slide the door along the rail to re-locate the hook-up point.

LAMP REPLACEMENT  (fig.3)

To replace the lamp, unscrew and remove the ceiling fixture support screw.
Slide the ceiling fixture in the direction shown by the arrow (fig.33).
Replace the lamp (220Vac , 40W max.).

Fig.2

Fig.3

Fig.1

A

B

LOCK

RELEASE

RE-LOCK

Summary of Contents for 525

Page 1: ...nt amendments 91 368 EEC 93 44 EEC and 93 68 EEC complies with the essential safety requirements in the following EEC Directives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent...

Page 2: ...temsweredesignedandbuilt for indoor use and for controlling vehicle access Avoid any other use 2 DIMENSIONS Fig 1 Fig 2 Power pipe 230V Cable 4 x 0 5 RX photocell Cable 3x0 5 Radio receiver Cable 2 x...

Page 3: ...by the automatic system Check if an efficient earth plate is available for electrical connection to the operator Make sure there is a clearance of at least 35 mm between the ceiling and the highest sl...

Page 4: ...e advise you to use the optional guide fig 8 ref B fitting it on the central slide fig 8 ref C 5 3 Insert the longitudinal member with chain in the central slide fig 9 until it meets the metal project...

Page 5: ...N B To apply tension to the chain turn the nut clock wise To slacken the chain turn the nut anti clock wise Warning too much chain tension could damage the motor unit 5 6 Offer the assembled guide to...

Page 6: ...spect to the door use a spirit level 6 8 When you have reached the correct position measure the distance between ceiling and operator so that you can shape the securing brackets in advance 6 9 Fit the...

Page 7: ...distance between drive bracket and sliding rail bracket must not exceed 20cm max 30 fig 24 6 22 Check the position drill and secure with suitable screws fig 24 Fig 25 LOCK Fig 26 6 23 Re lock the aut...

Page 8: ...Open push button P2 Set up push button LK1 Enable disable fail safe LK2 Varies sensitivity of reversing device Fig 27 fail safe enabled fail safe disabled LK1 reversing sensitivity 150N 15Kg LK2 rever...

Page 9: ...es to vary the sensitivity of the reversing device fig 27 Fig 28 OTHERSAFETYDEVICES STOP OPEN 8 ANTENNAINSTALLATION OPTIONAL 8 1 If you are using an RP receiver and wish to increase its range you can...

Page 10: ...ing push button dismantle the cour tesy light ceiling fixture unscrewing the appropriate screw Slidetheceilingfixtureinthedirectionshownbythearrow fig 34 INITIAL SET UP The obstacle detector does NOT...

Page 11: ...tronic appliance establishes the deceleration points and pause time is fixed at 3 minutes If the SETUP procedure was successful the courtesy lamp stays lightedfor5seconds Duringthistime inordertoreduc...

Page 12: ...tomated system and safety devices and then apply the danger warning sticker fig 35 on the panel of the up and over door to make it easy to see Apply the sticker which indicates the release device of t...

Page 13: ...n electronic device ensures that any obstacles are detected The door is normally closed when the electronic control unit receives an opening commandfromtheremotecontrol orfromanyothertypeofpulsegenera...

Reviews: