5. CONNECTIONS AND OPERATION

5.1

TERMINAL BOARD M1

22V power supply

Terminals “1-2”.  This is the input to which the secondary winding
of the transformer, powered at 22 V 50/60 Hz, should be
connected.  When power is supplied by the transformer, this is
signalled by the POWER LED lighting up.

Batteries

Terminals “3-4”.  The control unit is designed to operate with two
floating batteries (optional item) with minimum characteristics
as indicated on the table in paragraph 3.
When powered, the control unit keeps the batteries charged.
The batteries begin to operate when the transformer no longer
supplies power.
N.B.: power supplied by batteries should be considered an
emergency  situation – the minimum number of gate operations
is about 10/15. In any event, the number of possible operations
depends on the quality of the batteries, structure of gate, and
time elapsing since mains power failed, etc, etc..
N.B.:  observe the power polarity of the batteries

Accessories

Terminals “5-6”. Output for powering external accessories (24
Vdc).
N.B.: maximum load of accessories is 500 mA.

5.2

TERMINAL BOARD  M2

Gearmotor 1

Terminals “7-8”. Connect the motor for leaf 1 of twin-leaf gates
to power supply of 24 Vdc 70W max.
Use for gearmotor connection for single-leaf gates.

Gearmotor 2

Terminals “9-10”. Connect the motor for leaf 2 of twin-leaf gates
to power supply of 24 Vdc 70W max.
Do not connect for single-leaf gates.

Electric lock

Terminals “11-12”. Connect an electric lock operating on 24Vdc
24W max power supply.  Depending on gate structure and type
of electric lock fitted, dip-switch 5 can be used to set the leaf
reversing stroke enabling the electric lock to release.
N.B.: install the electric lock on the leaf on which gearmotor 1 is
fitted.

Flashlight

Terminals “13-12”. Use a flashlight with fixed light operating
voltage of 24Vdc 15W max.  We advise you to connect it before
programming, as it indicates programming stages. On opening,
it pre-flashes steadily for 0.5 seconds, and for 1.5 seconds at
closing. If the automatic logic is on, when the gate reaches the
opening gate stop, the flashlight stays on for 5 sec to inform the
user it will re-close automatically. When the gate is open, the
flashlight is off, and only flashes when the safety devices are in
use. If the devices are in use for a long time, flashing only lasts 10
sec.

Warning-light

Terminals “14-12”. Use a warning-light operating on 24Vdc 3W
max.  When the gate is closed, the warning-light is off, and goes
on at opening, gate open and closing stages.

5.3

TERMINAL BOARD  M3

OPEN-B  (For pedestrian use)

Terminals “15-19”.  Any device (e.g. push-button, remote control,
etc.) can be connected to this circuit.
By closing a contact, the circuit generates a pulse for partial
opening of the gate. If the gate has two leaves, a pulse fully
opens the leaf connected to gearmotor 1.  If the gate has one
leaf only,  the pulse partly opens the leaf (50% of work time).
N.B.: an OPEN-A pulse during the pedestrian stage always has
priority over that stage
N.B.: to install several pulse generators, connect the contacts in
parallel.

3. TECHNICAL SPECIFICATIONS

Supply voltage of transformer

230V~ (+ 6 % - 10 %) 50Hz

Supply voltage of control unit

22V~ (+ 6 % - 10 %) 50Hz

Power consumption

3 W

Motor max. load

2 x 70 W

Accessories max. load

24Vdc 500mA

Flashlight max. load

24Vdc 15W max

Ambient temperature

-20 ÷ +55 °C

Fuse

2

Function logics

Automatic / Stepped

Opening / closing time

Through self-learning at installation

Pause time

Through self-learning at installation

Thrust force

Two levels selected by Dip-switch

Time differences

Two levels selected by Dip-switch

Deceleration

At opening and closing during self-learning

Terminal board inputs

22 V~power supply / Battery power supply /

Total opening / Opening for pedestrians / Stop / Photocells

Quick connector

For decoding - RP receivers card

Terminal board outputs

24 Vdc accessories power supply / 24 Vdc Motors

Electric lock / 24 Vdc Flashlight / 24 Vdc Warning-light

Card dimensions

170 x 130 mm

Characteristics of toroidal transformer

prim. 230V~  sec. 22V~ / 150VA / dimens. Ø 105 x 40 mm

Characteristics of optional batteries

12V  4.5Ah / dimens. 90 x 70 x 108 mm

Characteristics of outdoor container

305 x 225 x 125 mm  - IP55

4. INSTRUCTIONS

WARNING:  To ensure people's  safety, all  warnings  and
instructions in this booklet must be  carefully observed.
Incorrect installation or use of the product could  cause serious
harm  to people.

Make sure there is an adequate differential switch upstream of
the system as specified by current laws,
and install a thermal breaker with all-
pole switch on the electrical mains.
To lay electrical cables, use adequate
rigid and/or flexible tubes.
Always separate  connection cables
of low voltage accessories from those
operating at 230 V~. To prevent any
interference whatever, use separate
sheaths.
The maximum length of power cables
between control unit and motors must
not exceed 10 m, using cables of
2.5mm² diameter.
Procedure  for securing components in the watertight container:
1) Secure the support of the toroidal transformer in position 

A

 by

fitting three Ø3.9x6.5 self-tapping screws (supplied) in the
guides of the watertight container.
N.B.: the support is sized to house a transformer (not supplied)
with characteristics and dimensions specified in the table in
paragraph 3.

2) Secure the transformer on the support with 2 clamps

(supplied).

3) If using floating batteries, secure the relevant support in position

B

 by fitting four Ø3.9x6.5 self-tapping screws (supplied) in the

crossover holes of the guides of the watertight container.
N.B.: the support is sized to house two batteries (not supplied)
with characteristics and dimensions specified in the table in
paragraph 3.

4) Position the batteries on the support.
5) Secure the control unit in position  

C

 by fitting four Ø3.9x6.5

self-tapping screws (supplied) in the guides of the watertight
container.

Summary of Contents for 424 MPS

Page 1: ... E R TIF I C A T A UNI EN ISO 9001 085 para la naturaleza 100 papel reciclado ist umweltfreundlich 100 Altpapier pour la nature papier recyclé 100 for nature recycled paper 100 carta riciclata 100 per la natura 424 MPS 424 MPS ...

Page 2: ...ni 1 40069 Zola Predosa BOLOGNA ITALY Declares that Electronic appliance 424MPS conforms to the essential safety requirements of the following directives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amendment 92 31 CEE and 93 68 EEC Additional information This product underwent tests in a typical uniform configuration all products manufactured by FAAC S p A Bologna 01 Jan...

Page 3: ...uilt in LEDs constantly indicate status of both control unit and gearmotor The control unit is designed for installation in a watertight outdoor use container which is also designed to house 2 optional batteries and a toroidal transformer with the characteristics shown in the table below 2 CONNECTION LAY OUT MICROPROCESSOR CONTROL UNIT FOR 24 Vdc SWING LEAF GATES 1 2 3 4 5 6 1 7 2 3 4 5 6 PROG OFF...

Page 4: ...rmotor 1 If the gate has one leaf only the pulse partly opens the leaf 50 of work time N B an OPEN A pulse during the pedestrian stage always has priority over that stage N B to install several pulse generators connect the contacts in parallel 3 TECHNICAL SPECIFICATIONS Supply voltage of transformer 230V 6 10 50Hz Supply voltage of control unit 22V 6 10 50Hz Power consumption 3 W Motor max load 2 ...

Page 5: ...ocells covered STOP stop command inactive command active N B LED status shown in bold with gate closed and control unit powered 9 PROGRAMMING Programming of work times deceleration and electronic clutch is executed during self learning At this stage leaf movement is at slow speed Important the self learning procedure must be executed with back up batteries optional disconnected Procedure 1 Release...

Page 6: ...papier pour la nature papier recyclé 100 for nature recycled paper 100 carta riciclata 100 per la natura Le descrizioni e le illustrazioni del presente manuale non sono impegnative La FAAC si riserva il diritto lasciando inalterate le caratteristiche essenziali dell apparecchiatura di apportare in qualunque momento e senza impegnarsi ad aggiornare la presente pubblicazione le modifiche che essa ri...

Reviews: