![FAAC 422 Standard Manual Download Page 6](http://html1.mh-extra.com/html/faac/422-standard/422-standard_manual_3109452006.webp)
6
D
E
F
AC Line
j
i
k
b
a
d
c
g
f
e
h
422 OPERATOR
A
38 7/8 in
B
27 1/4 in
C
9 1/2 in
D
3 3/8 in
E
4 3/4 in
F
2 3/8 in
1.1. DIMENSIONS
Fig. 1
h
Front bracket
i
Housing
j
Emergency release
k
Rear bracket
a
Electric motor
b
Release lock
c
Hydraulic piston
d
Cylinder
e
By-pass valves
f
Gerotor pump
g
Electrical cable
a
Operators mod. 422
b
Photocells
c
Electronic control unit
d
Key operated push-button
e
Radio receiver
f
Warning light
g
Electric lock (if necessary)
Fig. 3
Fig. 2
The self contained 422 operator is an electro-hydraulic unit
consisting of an electric motor, a pump, a valve assembly and
a hydraulic cylinder, all housed in an anodized aluminum oil
reservoir.
The standard model of the 422 operator (CBAC) comes with
hydraulic locks in both open and close positions. The optional
SB version doesn’t have any locks.
The hydraulic lock is a service device rather than a security de-
vice. Additional external locks are recommended if tight security
is needed.
The 422 operator is designed and built to automate vehicular
swing leaf gates. Do not use for any other purpose.
1. DESCRIPTION AND TECHNICAL SPECIFICATIONS
Tab. 1
:
Technical specifications
Input voltage
115Vac (+10% -6%) or
230Vac (+6% -10%)
Rod extension speed
0.5 in/sec (1.3 cm/s)
Pump flow rate
1 l/min
Traction and thrust force
1124 lbf (500 daN)
Operating ambient temperature
4°F +131°F (-20 °C +55°C)
Power
220 W
Current
2A (115V) - 1A (230V)
Motor rotation speed
1400 rpm
Thermal protection
120°C
Weight
15.4 lb (7 kg)
Type of oil
FAAC HP OIL
Protection class
IP 55
Leaf max width
10 ft (3m)
Leaf min width
5 ft (1.5 m)
Leaf max weigth
900 lb (410 Kg)
Use frequency
55 (cycles/hour)
Always separate the connection cables of the low voltage
accessories from the high voltage power cables. Use separate
conduits to avoid interference.
The installer is responsible for grounding the gate and operator
systems, for providing the main power breaker switch, and for
making sure that the entire gate system meets all applicable
electrical codes.
Make sure to locate all controls that operate the gate system
at least 6 ft away from any moving parts
.
1.2. WIRING