background image

422

422

Hydraulic Swing Gate Operator

FAAC International Inc.
Headquarter & East Coast Operations
3160 Murrell Road
Rockledge, FL 32955
Tel. 800 221 8278
www.faacusa.com

FAAC International Inc.

West Coast Operations

357 South Acacia Avenue

Fullerton, CA 92831

Summary of Contents for 422 Standard

Page 1: ...te Operator FAAC International Inc Headquarter East Coast Operations 3160 Murrell Road Rockledge FL 32955 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia...

Page 2: ...ns 7 2 3 General Rules 7 2 4 Installing the Operator 7 2 5 By Pass Valves adjustment 10 3 MANUAL OPERATION 10 5 1 Restoring Normal Operating Mode 10 4 MAINTENANCE AND REPAIRS 11 455D CONTROL BOARD 1 G...

Page 3: ...an usage Locate the gate such that persons will not come in contact with the vehi cular gate during the entire path of travel of the vehicular gate c The gate must be installed in a location so that e...

Page 4: ...ipment may reach high thermal temperatures during normal operation therefore use caution when touching the external housing of the gate operator Use the manual release mechanism according to the proce...

Page 5: ...factory or loa ding dock area or other locations not accessible by or intended to service the general public CLASS IV RESTRICTED ACCESS VEHICULAR GATE OPERATOR A vehicular gate operator or system int...

Page 6: ...t security is needed The 422 operator is designed and built to automate vehicular swing leaf gates Do not use for any other purpose 1 DESCRIPTION AND TECHNICAL SPECIFICATIONS Tab 1 Technical specifica...

Page 7: ...not be obtai ned the following general rules can be used determine diffe rent installation dimensions to obtain 90 opening of the leaf a b rod stroke to obtain over 90 opening of the leaf a b rod stro...

Page 8: ...emove the front mounting bracket from the piston rod Spot weld the front bracket on the leaf protecting the rod against any welding waste WARNING Do not weld the front mounting bracket with the operat...

Page 9: ...iston should not bottom out in either direction Be sure that the gate reaches the positive stop before the piston bottoms out Attach the connector with the cable and secure it with the supplied screws...

Page 10: ...o reduce pressure turn the screws counterclockwise To increase pressure turn the screws clockwise When the adjustment is complete re position the knob Fig 15 ref d and tight the screw Fig 15 ref c Clo...

Page 11: ...tically with the rear flange high up Remove the oil filling plug Insert a screwdriver until it comes into contact with the electric motor as shown in Fig 18 Remove the screwdriver and check oil level...

Page 12: ...n be excluded Thrust Force Adjustable on 50 levels for each motor Terminal Board Inputs Open Open Free Leaf Stop Limit switch Opening Safety Devices Closing Safety Devices Power Supply Earth Terminal...

Page 13: ...connected to this input See the next paragraph on how to connect a monitored device If this input is active when the gate is open it will prevent the leaf closing movement OP FSW Opening safety devic...

Page 14: ...e connected for the system to work 1 2 5 4 3 1 2 RX CL TX CL 9 10 11 12 13 14 15 16 17 18 19 OPEN A B STP CL OP FSW 24V TX FSW 20 21 W L LOCK 1 2 5 4 3 1 2 RX OP TX OP 1 2 5 4 3 1 2 RX CL TX CL 9 10 1...

Page 15: ...act Typically these photocells work in combination with other monitored photocell pro tecting closing or opening entrapment zones In that case they can t be monitored so they can only protect against...

Page 16: ...ill display the param eter s current value Value can be modified with keys and Press and hold F again the unit will display the name of the next function parameter When you reach the last function pre...

Page 17: ...nd OFF when gate is closed the output is ON when the gate is open or in pause OFF in all other conditions the output is ON when the gate is closed OFF in all other conditions All other values correspo...

Page 18: ...and black wires on the 455 D control board 7 Check force setting of the motors modify if necessary Note For hydraulic operators like the 400 force should be programmed to maximum level 50 8 Stop leaf...

Page 19: ...2 stops at opening and immediately begins its closing movement 5 Slow down at closing of leaf 2 6 Leaf 2 stops at closing and leaf 1 begins its closing movement 7 Slow down at closing of leaf 1 8 Leaf...

Page 20: ...i t n o c e s a e l e r n o d n a s k c o L g n i n e p o D E K C O L 3 f a e l e h t s e s o l C t c e f f e o N d e l b a s i d N E P O t c e f f e o N t c e f f e o N d e l b a s i d N E P O E c i...

Page 21: ...diately stops operation NB Effects on other active pulse inputs in brackets P A c i g o L S E S L U P S U T A T S E T A G A N E P O B N E P O P O T S S E C I V E D Y T E F A S G N I N E P O S E C I V...

Page 22: ...OR 1 MOTOR 2 CL COM OP 1 2 3 4 5 6 7 8 20 21 FCA1 FCA2 FCC2 FCC1 F J2 J6 J4 J5 J3 N L MAIN OP CL 24 V FSW B STOP A TX FSW 9 10 11 12 13 14 15 16 17 18 19 J1 PHOTO OP OPEN DEVICES PHOTO CL 24VDC RX PHO...

Page 23: ...prewired enclosure comes with dedicated terminal blocks for the connection of safety photocells that can be monitored by the control board for presence and correct operation One closing and one openi...

Page 24: ...ections If using non FAAC relay make sure the minimum switch volt age is less than 12Vac SHADOW INPUT Line Voltage MOTOR ON 24 VDC SHADOW LOOP 120V or 230 AC SHADOW KIT OPTION 8 7 10 1 2 5 Shadow Loop...

Page 25: ...25 This page is intentionally left blank...

Page 26: ...er Washer 12 77000425 Motor 115V 1400 Rpm 25uF 7700205 Motor 220V 1400 Rpm 8uF 15 7182175 Long Pin 16 7110015 Oil Plug 21 3204425 Cast Iron Pump Lobe 1 Lt 22 7090010015 O Ring 4 48 x 1 78 mm 23 630033...

Page 27: ...366065 Cylinder 4 7095035 Piston Rod Packing 5 4350085 Piston Assembly 6 4994165 Front Flange 7 63000655 Front Flange Seal 10 pc pack 8 7090350025 O Ring 34 6 x 2 62 mm 9 63003305 Retract Tube and Tie...

Page 28: ...7 Washer Cup Spring 30 pc pack 3 4404085 Lock Valve 4 4180285 Shuttle Piston 5 7090300015 O Ring 7 66 x 1 78 mm 20 pc pack 6 7090010015 O Ring 4 48 x 1 78 mm 7 4404095 Inlet Valve Bi Directional 8 418...

Page 29: ...Base to Body 4 7275275 Keyhole Cover 5 7131005 Viro Manual Release Door Key 6 490326 Manual Release Kit 7 7090855 O Ring Locking Cap 8 7090845 O Ring Extensions Part Part Number Description 1 7171485...

Page 30: ..._________________________________________________________ _________________________________________________________________________________________ ____________________________________________________...

Page 31: ...sume for them any other liability in connection with the sale or use of the products of beyond that extended herein The warranty hereinabove set forth shall not be deemed to cover maintenance parts in...

Page 32: ...2021 FAAC International Inc All Rights Reserved Published in Jan 2021 422 732870 Rev D US...

Reviews: