background image

  

BOARD SETUP

   DS 1: SW 4 to SW 12

OPENING DELAY

SW 4

The opening of leaf 2 is delayed after the opening of leaf 1. This is to 
avoid that the gate’s leafs interfere with each other during the initial part 
of the movement. In case there is only one leaf is has no effect.

0   sec (default)

OFF

2   sec

ON

REVERSE AND LAST STROKE

SW 5

If active, before opening, while the gate is closed, the motors thrust to 
close for 2 s to facilitate the release of the electric lock. At closing the 
motors are activated for a final stroke after slowdown to facilitate locking 
of the electric lock.  

inactive   (default)

OFF

active

ON

MAX THRUST AT STARTUP 

SW 6

With this fuction active the motors work at maximum force at startup 
(regardless of the force setting) during the initial phase of the movement. 
Useful for heavy leafs

inactive   (default)

OFF

active for 3 sec

ON

AUTOMATIC OPENING IN CASE OF PO-

WER FAILURE

SW 7

If active and with the optional backup battery installed, the board will 
open the gate after one minute from the power failure and keep it open.
Within the minute wait it’s always possible to open and close the gate 
with a command. If the logic used has a pause time the board will close 
the gate when the power comes back.

inactive  (default)

OFF

active

ON

CLOSING SAFETY LOGIC

SW 8

With this function you can choose the behaviour of the closing safety. With 
SW8 OFF the gate movement will be reversed as soon as the safety is active, 
with SW8 ON the gate will stop when the safety is active and it will reverse 
only when the safety is deactivated again.

immediate reverse  (default)

OFF

reverse when cleared

ON

PREFLASHING

SW 9

This function activates the flashing lamp for 5s before the movement 
of the gate 

inactive   (default)

OFF

active for 5 sec

ON

EXTRA SENSITIVITY TO 

OBSTACLE DETECTION

SW 10

If active this function allows to have an immediate reverse in case the 
gate hits a rigid obstacle. This function increases the safety of the gate 
operator, however it can generate unwanted obstacle detections.

inactive   (default)

OFF

active

ON

ORANGE TERMINAL FUNCTION

SW 11

If OFF after the second consecutive obstacle detection this output is 
activated until the STOP contact is open or the power is cycled
if ON the output can be connected to a warning lamp. 

IMPORTANT: for UL325 compliance this switch must be OFF

Audio Alarm (default)

OFF

Warning Lamp

ON

OUT FUNCTION (pin 9)

max 100mA

SW 12

if OFF: use pin 9 as power supply negative for a warning lamp. The 
lamp will be active during opening, pause and stop. Flashing during 
close, off when the gate is closed
If ON: use pin 9 as power supply negative for the safety photocells.  
Before any movement the board will check for the presence of the 
safety photocells. If the test fails the gate will not move. 

IMPORTANT: for UL325 compliance this switch must be ON

Lamp

OFF

Photocells FAIL SAFE active 

ON

4.3  DIP SWITCH DS1 SETTINGS FOR BOARD SETUP

A8

Summary of Contents for 3350.1

Page 1: ...AAC International Inc Headquarter East Coast Operations 3160 Murrell Rd Rockledge FL 32955 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia Avenue Fullerton CA 92831 UL325 UL991 ...

Page 2: ...ssory power supply Programming With trimmers dipswitches and pushbutton RADIO Connector for the radio receiver BATTERY Connector for the backup battery J24 Jumper to disable battery charging With the jumper present the battery is charged POWER SUPPLY DC Power supply input TR1 to TR6 Programming Trimmers 24 LED DC power indicator SW1 SETUP Pushbutton for automatic setup DS1 DS2 Programming dipswitc...

Page 3: ... negative for warning lamp DS1 SW12 OFF 24 Vdc negative for safety TX photocell monitored DS1 SW12 ON IMPORTANT for UL325 compliance the negative TX photocell option must be used 10 FCA 1 Open limit switch Motor 1 11 GND 24 Vdc negative 12 FCC 1 Close limit switch Motor 1 13 FCA 2 Open limit switch Motor 2 14 GND 24 Vdc negative 15 FCC2 Close limit switch Motor 2 LAMP LAMP Audio Alarm output DS1 S...

Page 4: ...able for protecting the area between the open ing leaves and fixed obstacles walls etc against the risk of entrapment Closing Safety Devices They are active only during the gate closing movement and are suitable for protecting the closing area against the risk of entrapment Monitored Devices Additionaly the UL325 standard requires that every external entrapment protection device must be monitored ...

Page 5: ...during the gate opening and closing move ments and are suitable to protect the opening and closing areas against the risk of impact Typically these photocells work in combination with other monitored photocell pro tecting closing or opening entrapment zones In that case they can t be monitored so they can only protect against potential impact on vehicles CLOSE SAFETY MONITORED CL OP FSW OPEN CLOSE...

Page 6: ...vement a command stops the gate AP Automatic step by step OFF ON ON 0 4 min One command opens waits for the pause time and then closes automatically A command during the pause time holds the gate open SP Security step by step ON OFF OFF 0 4 min One command opens waits for the pause time and then closes automatically If the closing safety is activated during pause time the gate closes in 5 s A comm...

Page 7: ...AUSE TIME ADJUSTMENT 0 4 min Turn clockwise to increase the pause time TR6 CLOSING DELAY OF LEAF 1 OVER LEAF 2 ADJUSTMENT 0 15 sec Turn clockwise to increase the delay TR1 FORCE ADJUSTMENT MOTOR 1 Turn clockwise to increase the opening and closing force 1 min 2 min 3 min 4 min 0 sec 30 sec TR 2 FORCE ADJUSTEMENT MOTOR 2 Turn clockwise to increase the opening and closing force 4 2 ADJUSTING TRIMMER...

Page 8: ...ty With SW8 OFF the gate movement will be reversed as soon as the safety is active with SW8 ON the gate will stop when the safety is active and it will reverse only when the safety is deactivated again immediate reverse default OFF reverse when cleared ON PREFLASHING SW 9 This function activates the flashing lamp for 5s before the movement of the gate inactive default OFF active for 5 sec ON EXTRA...

Page 9: ...0H S800H OFF OFF OFF S418 OFF OFF ON 415 390 770 ON OFF OFF DS 2 LOCK OUTPUT MODE OUTPUT MODE SW 4 Active only for 3 sec after an open impulse from gate closed OFF Active always except 3 sec before an opening ON SETTING DL 1 DL 2 DL 3 DL 4 DL 5 J24 IMPORTANT 4 4 DIP SWITCH DS2 SETTINGS FOR OPERATOR TYPE AND LOCK MODE 5 LED DIAGNOSTICS A9 ...

Page 10: ... B active OPEN B not active LED DL 16 STOP INPUT N C STOP non active STOP active or wiring error LED DL 17 FSW CL INPUT N C Closing safety devices clear Closing safety devices triggered or wiring error LED DL 18 FSW OP INPUT N C Opening safety devices clear Opening safety devices triggered or wiring error 9 LED DL 19 FCA1 OPEN LIMIT SWITCH MOT1 N C Limit switch OFF or not used Limit Switch activat...

Page 11: ...fy the encoder wiring and LED status If they are correct replace the encoder Verify motor and encoder wire gauge are correct Verify operator is not on manual and hydraulic units don t need to be bled 6 FAIL SAFE FAILED Verify the photocells wiring and alignement 7 BOARD THERMAL PROTECTION ACTIVE Turn off the board and wait until the components cool down 8 MAX RUN TIME REACHED WITHOUT FINDING THE P...

Page 12: ...ompletely open execute a close in Automatic mode if the gate was not completely open execute an open wait for the pause time and then closes if the gate was completely open reload the pausetime and then closes If there is another obstacle detection complete stop alarm goes off If the gate reaches the close position obstructions count reset return to normal operations 7 At the point where you want ...

Page 13: ...d plug it on the BATTERY connector on the board Plug the other end of the cable to the batteries red wire to 24 and black wire to GND SETTING DL 1 DL 2 DL 3 DL 4 DL 5 J24 8 1 POWER SUPPLY FUSE AC POWER GUIDELINES THE E024U control board and power supply uses a single phase AC power line to operate charge the batteries and power gate accessories Use the following guidelines when installing the AC p...

Page 14: ...ginning of the software update WARNING DON T TURN THE POWER OFF OR REMOVE THE FLASH DRIVE UNTIL THE USB2 LED TURNS OFF 4 Wait until the USB 2 LED turns off 5 Remove the USB Flash drive 6 Cycle power reconnect the batteries if needed and exe cute a new SETUP procedure See chapter 6 For the upgrade you need a USB Flash Drive where you have to copy the file supplied by FAAC Then follow these steps WA...

Page 15: ...at release OPEN stops saves CLOSE OPEN recloses leaves immediately 1 recloses leaves immediately no effect OPEN CLOSE disabled no effect no effect CLOSE disabled no effect OPEN CLOSE disabled CLOSING reopens leaves immediately reopens leaves immediately stops operation no effect reverses at opening stops and opens at release OPEN stops saves CLOSE BLOCKED closes leaves closes leaves no effect OPEN...

Page 16: ...CLOSE disabled recharges pause time CLOSE disabled CLOSING reopens leaves immediately reopens leaves immediately stops operation no effect reverses at opening see DS1 SW8 stops and opens at release OPEN stops saves CLOSE BLOCKED closes leaves closes leaves no effect OPEN CLOSE disabled no effect OPEN disabled no effect CLOSE disabled no effect OPEN CLOSE disabled 1 if the cycle began with OPEN B l...

Page 17: ...E disabled no effect OPEN disabled no effect CLOSE disabled no effect OPEN CLOSE disabled LOGIC C CONTINUOS COMMANDS PULSES SYSTEM STATUS OPEN A OPEN B STOP FSW OP FSW CL FSW CL OP CLOSED opens the leaves no effect no effect OPEN disabled no effect OPEN disabled no effect no effect OPEN disabled OPENING no effect closes leaves stops operation reverses at closure no effect stops and at release clos...

Page 18: ...en subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding those set forth in the specifications for such product s Neither FAAC S p A nor FAAC International Inc shall be liable for any loss or damage whatsoever resulting directly or indir...

Reviews: