background image

A10

L

E

D

DESCRIPTION

LED STATUS 

In BOLD the normal state with gate closed and working

ON STEADY

OFF

BLINKING

1

LED BATTERY

Board working on AC 

power

Board working on

battery power or ext

supply

Battery charging

2

LED +24 

Main power present

Main power OFF

3

LED SET-UP

Normal operation

SLOW BLINK 

(1 sec. ON - 1 sec. OFF)

SET-UP needed 

FAST BLINK

(0.5 sec. ON - 0.5 sec OFF)

SET UP in in progress 

4

LED ERROR

Board malfunction.

See possible causes 

below

No errors

Error conditions. 

See LED ERROR DISPLAY table

5

LED BUS_MON

Communication  on  

Bus “2easy” OK

Communication bus 

“2Easy” inactive. Verify

the bus “2Easy” devices

for shorts

Bus 2Easy devices with the 

Same address. Verify dip switch

Setting on photocells or 

Encoder LEDs 

6

LED USB

Software update done

or USB key not present

USB key inserted and software

Update in progress 

(DON’T Remove the USB key)

7

RESERVED

  

 

8

LED   DL 14  

OPEN A INPUT (N.O.)

OPEN A active

OPEN A not active  

LED   DL 15

OPEN B INPUT (N.O.)

OPEN B  active

OPEN B not active  

LED   DL 16  

STOP INPUT (N.C.)

STOP non active

 STOP active or 

wiring error

LED   DL 17  

FSW CL INPUT (N.C.)

Closing safety 

devices clear

Closing safety devices

triggered or wiring error

LED   DL 18 

FSW OP INPUT (N.C.)

Opening safety

 devices clear

Opening safety devices

triggered or wiring error

9

LED DL 19 FCA1: OPEN

LIMIT SWITCH MOT1 (N.C.)

Limit switch

OFF or not used 

Limit Switch activated

LED DL 20 FCC1: CLOSE

LIMIT SWITCH MOT1 (N.C.)

Limit switch

OFF or not used 

Limit Switch activated

10

LED DL 21 FCA2: CLOSE

LIMIT SWITCH MOT2 (N.C.)

Limit switch

OFF or not used 

Limit Switch activated

LED DL 22 FCC2: CLOSE

LIMIT SWITCH MOT2 (N.C.)

Limit switch

OFF or not used 

Limit Switch activated

BOARD MALFUNCTION ERROR POSSIBLE CAUSES

SOLUTIONS

There were two consecutive obstacle detections (the audio alarm also should sound)

Remove obstructions

One of the motor driver components has failed

The board needs to be repaired

The idle current in one of the motors is out of range

Check the motors

Both limit switches are active at the same time

Check the limit switches

Input voltage from the power supply is out of range

Check DC input voltage

A10

Summary of Contents for 3350.1

Page 1: ...AAC International Inc Headquarter East Coast Operations 3160 Murrell Rd Rockledge FL 32955 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia Avenue Fullerton CA 92831 UL325 UL991 ...

Page 2: ...ssory power supply Programming With trimmers dipswitches and pushbutton RADIO Connector for the radio receiver BATTERY Connector for the backup battery J24 Jumper to disable battery charging With the jumper present the battery is charged POWER SUPPLY DC Power supply input TR1 to TR6 Programming Trimmers 24 LED DC power indicator SW1 SETUP Pushbutton for automatic setup DS1 DS2 Programming dipswitc...

Page 3: ... negative for warning lamp DS1 SW12 OFF 24 Vdc negative for safety TX photocell monitored DS1 SW12 ON IMPORTANT for UL325 compliance the negative TX photocell option must be used 10 FCA 1 Open limit switch Motor 1 11 GND 24 Vdc negative 12 FCC 1 Close limit switch Motor 1 13 FCA 2 Open limit switch Motor 2 14 GND 24 Vdc negative 15 FCC2 Close limit switch Motor 2 LAMP LAMP Audio Alarm output DS1 S...

Page 4: ...able for protecting the area between the open ing leaves and fixed obstacles walls etc against the risk of entrapment Closing Safety Devices They are active only during the gate closing movement and are suitable for protecting the closing area against the risk of entrapment Monitored Devices Additionaly the UL325 standard requires that every external entrapment protection device must be monitored ...

Page 5: ...during the gate opening and closing move ments and are suitable to protect the opening and closing areas against the risk of impact Typically these photocells work in combination with other monitored photocell pro tecting closing or opening entrapment zones In that case they can t be monitored so they can only protect against potential impact on vehicles CLOSE SAFETY MONITORED CL OP FSW OPEN CLOSE...

Page 6: ...vement a command stops the gate AP Automatic step by step OFF ON ON 0 4 min One command opens waits for the pause time and then closes automatically A command during the pause time holds the gate open SP Security step by step ON OFF OFF 0 4 min One command opens waits for the pause time and then closes automatically If the closing safety is activated during pause time the gate closes in 5 s A comm...

Page 7: ...AUSE TIME ADJUSTMENT 0 4 min Turn clockwise to increase the pause time TR6 CLOSING DELAY OF LEAF 1 OVER LEAF 2 ADJUSTMENT 0 15 sec Turn clockwise to increase the delay TR1 FORCE ADJUSTMENT MOTOR 1 Turn clockwise to increase the opening and closing force 1 min 2 min 3 min 4 min 0 sec 30 sec TR 2 FORCE ADJUSTEMENT MOTOR 2 Turn clockwise to increase the opening and closing force 4 2 ADJUSTING TRIMMER...

Page 8: ...ty With SW8 OFF the gate movement will be reversed as soon as the safety is active with SW8 ON the gate will stop when the safety is active and it will reverse only when the safety is deactivated again immediate reverse default OFF reverse when cleared ON PREFLASHING SW 9 This function activates the flashing lamp for 5s before the movement of the gate inactive default OFF active for 5 sec ON EXTRA...

Page 9: ...0H S800H OFF OFF OFF S418 OFF OFF ON 415 390 770 ON OFF OFF DS 2 LOCK OUTPUT MODE OUTPUT MODE SW 4 Active only for 3 sec after an open impulse from gate closed OFF Active always except 3 sec before an opening ON SETTING DL 1 DL 2 DL 3 DL 4 DL 5 J24 IMPORTANT 4 4 DIP SWITCH DS2 SETTINGS FOR OPERATOR TYPE AND LOCK MODE 5 LED DIAGNOSTICS A9 ...

Page 10: ... B active OPEN B not active LED DL 16 STOP INPUT N C STOP non active STOP active or wiring error LED DL 17 FSW CL INPUT N C Closing safety devices clear Closing safety devices triggered or wiring error LED DL 18 FSW OP INPUT N C Opening safety devices clear Opening safety devices triggered or wiring error 9 LED DL 19 FCA1 OPEN LIMIT SWITCH MOT1 N C Limit switch OFF or not used Limit Switch activat...

Page 11: ...fy the encoder wiring and LED status If they are correct replace the encoder Verify motor and encoder wire gauge are correct Verify operator is not on manual and hydraulic units don t need to be bled 6 FAIL SAFE FAILED Verify the photocells wiring and alignement 7 BOARD THERMAL PROTECTION ACTIVE Turn off the board and wait until the components cool down 8 MAX RUN TIME REACHED WITHOUT FINDING THE P...

Page 12: ...ompletely open execute a close in Automatic mode if the gate was not completely open execute an open wait for the pause time and then closes if the gate was completely open reload the pausetime and then closes If there is another obstacle detection complete stop alarm goes off If the gate reaches the close position obstructions count reset return to normal operations 7 At the point where you want ...

Page 13: ...d plug it on the BATTERY connector on the board Plug the other end of the cable to the batteries red wire to 24 and black wire to GND SETTING DL 1 DL 2 DL 3 DL 4 DL 5 J24 8 1 POWER SUPPLY FUSE AC POWER GUIDELINES THE E024U control board and power supply uses a single phase AC power line to operate charge the batteries and power gate accessories Use the following guidelines when installing the AC p...

Page 14: ...ginning of the software update WARNING DON T TURN THE POWER OFF OR REMOVE THE FLASH DRIVE UNTIL THE USB2 LED TURNS OFF 4 Wait until the USB 2 LED turns off 5 Remove the USB Flash drive 6 Cycle power reconnect the batteries if needed and exe cute a new SETUP procedure See chapter 6 For the upgrade you need a USB Flash Drive where you have to copy the file supplied by FAAC Then follow these steps WA...

Page 15: ...at release OPEN stops saves CLOSE OPEN recloses leaves immediately 1 recloses leaves immediately no effect OPEN CLOSE disabled no effect no effect CLOSE disabled no effect OPEN CLOSE disabled CLOSING reopens leaves immediately reopens leaves immediately stops operation no effect reverses at opening stops and opens at release OPEN stops saves CLOSE BLOCKED closes leaves closes leaves no effect OPEN...

Page 16: ...CLOSE disabled recharges pause time CLOSE disabled CLOSING reopens leaves immediately reopens leaves immediately stops operation no effect reverses at opening see DS1 SW8 stops and opens at release OPEN stops saves CLOSE BLOCKED closes leaves closes leaves no effect OPEN CLOSE disabled no effect OPEN disabled no effect CLOSE disabled no effect OPEN CLOSE disabled 1 if the cycle began with OPEN B l...

Page 17: ...E disabled no effect OPEN disabled no effect CLOSE disabled no effect OPEN CLOSE disabled LOGIC C CONTINUOS COMMANDS PULSES SYSTEM STATUS OPEN A OPEN B STOP FSW OP FSW CL FSW CL OP CLOSED opens the leaves no effect no effect OPEN disabled no effect OPEN disabled no effect no effect OPEN disabled OPENING no effect closes leaves stops operation reverses at closure no effect stops and at release clos...

Page 18: ...en subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding those set forth in the specifications for such product s Neither FAAC S p A nor FAAC International Inc shall be liable for any loss or damage whatsoever resulting directly or indir...

Reviews: