6.13 Operating times of an
FSG 90
(6 Watt version) supplied from a
12 V battery only
The following duty cycle of Transmit (TX), Receive (RX) and Standby (STBY) results in
available operating time (hours). Both the worst and the most favourable operation
conditions are considered, e.g. maximum receiver volume combined with maximum
speaker load (2 speakers, 4 Ohms each).
Higher current consumption will degrade the nominally available battery capability, as
well as lower temperatures. The following tables show significant time differences
depending on current consumption during Receive, and at temperatures.
Prerequisite: Maximum RX audio volume, AF External ON
Max. current drain
.11 A
2.5 A 1.0 A .11 A 2.5 A 1.0 A .11 A 2.5 A 1.0 A .11 A
Lead Accumulator
12 Volts
7.2 Ah
STBY,
w/out RX
5%
TX
5%
RX
90%
STBY
10%
TX
20%
RX
70%
STBY
20%
TX
40%
RX
40%
STBY
Temperature
- 20°C/-4°F
38 hrs.
12.30 hrs.
6.00 hrs.
3.10 hrs.
Temperature
+20°C/68°F
62 hrs.
20.10 hrs.
10.00 hrs.
5.20 hrs.
Temperature
+50°C/122°F
66 hrs.
22.10 hrs.
11.10 hrs.
6.00 hrs.
Prerequisite: Minimum RX audio volume, AF External OFF (power saving)
Max. current drain
.08 A
2.5 A .25 A .08 A 2.5 A .25 A .08 A 2.5 A .25 A .08 A
Lead Accumulator
12 Volts
7.2 Ah
STBY,
w/out RX
5%
TX
5%
RX
90%
STBY
10%
TX
20%
RX
70%
STBY
20%
TX
40%
RX
40%
STBY
Temperature
-20°C/-4°F
57 hrs.
15.50 hrs.
8.50 hrs.
4.40 hrs.
Temperature
+20°C/68°F
85 hrs.
26.10 hrs.
14.30 hrs.
7.50 hrs.
Temperature
+50°C/122°F
90 hrs.
28.40 hrs.
16.20 hrs.
8.40 hrs.
6.14 Emergency Operation
Even under low / emergency supply conditions, the
FSG 90(X)
can be operated reliably
from as low as 10 Volts supply. This however will reduce both the RF output level and
audio output power.
Batteries must be recharged after discharge. However, the
FSG 90(X)
automatic switch-
OFF feature at too low supply avoids battery damage, even if the radio is stored in
switched ON condition! This is true for all types of 12 V batteries.
Summary of Contents for FSG 90
Page 2: ...FSG 90 System Airband Transceiver ii FAV_D10024 December 2014 ...
Page 69: ...FSG 90 System Appendix A December 2014 FAV_D10024 63 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 71: ...FSG 90 System Appendix B December 2014 FAV_D10024 65 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 73: ...FSG 90 System Appendix C June 2014 FAV_D10024 67 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 74: ...FSG 90 System Appendix D 68 FAV_D10024 December 2014 Appendix D Certificates ...
Page 75: ...FSG 90 System Appendix D December 2014 FAV_D10024 69 ...
Page 76: ...FSG 90 System Appendix D 70 FAV_D10024 December 2014 ...
Page 77: ...FSG 90 System Appendix D December 2014 FAV_D10024 71 ...
Page 78: ...FSG 90 System Appendix D 72 FAV_D10024 December 2014 ...
Page 79: ...FSG 90 System Appendix D December 2014 FAV_D10024 73 ...
Page 80: ......