CONNECTING SOURCES 

The Multizone Controller provides 6 x stereo unbalanced line level source inputs which can be accessed by any zone. Input 1 can be used as a paging (all 

zones) input or a party mode (all zones) input. When a source is connected to input 1 and 12VDC is applied to the PA-IN jack (3.5mm tip+ sleeve -), source 1 

will be broadcast in all zones. If there is no DC voltage applied to the PA-IN jack then source 1 will act like all the other 5 sources and broadcast only when a 

zone selects source 1. Always use good quality shielded RCA cables to connect sources to the Multizone Controller and keep RCA cables as short as possible 

to avoid RF interference. 

INFRARED EMITTER OUTPUTS 

This system has the ability to repeat IR signals from each speaker zone to control the source devices. The IR signal from the Master Controller to the 

source device requires IR emitters (not included) connected to the Master Controller via a 3.5mm TS plug. The IR repeater function supports single-band IR 

signals in the 38KHz range only. To install an IR emitter, insert the 3.5mm plug for the emitter into the appropriate IR emitter jack. Position the emitter 

bulb so that it is within range and has a clear line-of-sight to the source device(s). If the emitter cord is not long enough, you can use any 3.5mm TS or TRS 

extension cable to extend its reach. 

 

 

 

 

 

Summary of Contents for eZi-DA66

Page 1: ...eZi DA66 Installation Manual Revision 1 2 Page 1 Professional Multi Room 6 Source 6ZoneAudio System User and Installation Manual Home Audio Distribution System eZi DA66 eZi DA66...

Page 2: ...D WIRING 9 KEYPAD CABLE INFORMATION 10 INSTALLATION OF KEYPAD HUB EARTH 10 INSTALLATION OF KEYPAD HUB CAT5 10 SPEAKER INSTALLATION IMPORTANT 11 SPEAKER INSTALLATION STEREO MODE SPEAKER INSTALLATION BR...

Page 3: ...this device 7 Unplug the unit during lightning storms or when the unit will be unused for a long period of time 8 Do not allow the power cords to be walked on pinched tripped over or otherwise damage...

Page 4: ...in a safe place for future reference PACKAGE CONTENTS After receiving the product please inventory the contents to ensure you have all the parts listed below If anything is missing or damaged please c...

Page 5: ...s with 3 x Multizone Controller systems RS232 Control eZi UHAP or MZC emulation Dual Voltage Selector MUST BE 230V 12 high quality amplifiers with 50 watts output power 4ohms or 100 watts 8ohms in bri...

Page 6: ...also sends IR commands to the Multizone Controller master controller IR output jacks for remote control of your source components No programming necessary just touch the keypad and start playing music...

Page 7: ...66 Installation Manual Revision 1 2 Page 7 INFRARED REMOTE CONTROL Infrared IR emitter Zone power on off Bass up down Balance right Zone mute Source selection 1 6 Treble up down Volume up down Balance...

Page 8: ...onnectors for all Multizone Controller keypads 5 The Multizone Controller includes a central keypad hub All Multizone Controller keypads will be home run back the hub Keep the hub close the Multizone...

Page 9: ...can damage the keypad Use a good quality Cat5e 6 cable and crimp RJ45 jacks on each end of the cables The RJ45 jack plugs into the back panel of the keypads and the 6 x RJ45 jacks on the keypad hub T...

Page 10: ...e Keypad Hub and the other end of the fly lead to an earth point Please ensure that the earth connection is tested to the earth of the installation without a reliable earth connection the energy gener...

Page 11: ...terminal block connectors are removable Remove the terminal block connector and make sure that all connections are open by turning each set screw counter clockwise This insures that the speaker wire o...

Page 12: ...o the 6 x zone outputs PRE AMP outputs can be used to connect powered subwoofers to a zone or additional amplifiers to expand the available power in a large zone or multiple zones The eZi DA66 Control...

Page 13: ...bles to connect sources to the Multizone Controller and keep RCA cables as short as possible to avoid RF interference INFRARED EMITTER OUTPUTS This system has the ability to repeat IR signals from eac...

Page 14: ...orresponding zone sends 12VDC to the trigger output jack When the zone is powered OFF the routed 12VDC signal is disengaged Triggers can be used to automatically power peripheral equipment ON OFF with...

Page 15: ...ll be the Master device Slide the Master Slave switch on this unit to the Master position 2 Plug one end of the included ribbon cable into the Expansion Output port on the back of the Master device Pl...

Page 16: ...nstructions SPECIFICATIONS RMS Power 8Ohms 25 watts x 12 Trigger Systems ON Voltage 12v DC RMS Power 4Ohms 50 watts x 12 Trigger External Mute Voltage 12v DC RMS Power 8 Ohms Bridged 100 watts x 6 Inf...

Reviews: