eZi eZi-DA66 User And Installation Manual Download Page 11

eZi-DA66 Installation Manual  

Revision 1.2 

 

 

 

 

 

 

 

Page                11 

 

 

SPEAKER INSTALLATION – IMPORTANT  

IMPORTANT: The Multizone Controller amplifiers are capable of driving 4 Ω to 8 Ω speaker loads in stereo mode and 8 Ω loads in bridge mono mode. 

Never connect more than two 8 Ω speakers wired in parallel to a single amplifier channel in stereo mode. Never connect more than one 8 Ω speaker to a 

single channel in bridge mono mode. Never connect the Left & Right channels of the amplifier together. Never combine the – negative channels of the 

amplifier together. Improper speaker installation can damage the amplifiers and void the warranty. If you are unsure how to connect speakers to the 

Multizone Controller always contact a qualified technician or contact iLED before connecting speakers to the amplifiers. 

SPEAKER INSTALLATION – STEREO MODE   

 

 

 

 

SPEAKER INSTALLATION -  BRIDGE MODE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use good quality 2mm

2

 to 3mm

2

  (12 to 14awg) stranded copper speaker 

wire that shows the – and +. Never run speaker wires parallel to AC wires. If 
you  must  cross  AC  wires  always  cross  at  a  90-degree  angle.  The  speaker 
output  terminal  block  connectors  are  removable.  Remove  the  terminal 
block  connector  and  make  sure  that  all  connections  are  open  by  turning 
each set screw counter clockwise. This insures that the speaker wire opening 
is completely open. Trim approx. 6mm of insulation from the speaker wire 
and twist the copper ends. Insert the speaker wires into the connector and 
tighten  the  set  screws.  Always  connect  Amplifier  +  to  Speaker  +  and 
Amplifier - to Speaker. Make sure the Bridged switch is set to NO. Repeat for 
the remaining zones 

Use good quality 2mm

2

 to 3mm

2

  (12 to 14awg) stranded copper speaker 

wire that shows the – and +. Never run speaker wires parallel to AC wires. 
If you must cross AC wires always cross at a 90-degree angle. The speaker 
output  terminal  block  connectors  are  removable.  Remove  the  terminal 
block connector and make sure that all connections are open by turning 
each  set  screw  counter  clockwise.  This  insures  that  the  speaker  wire 
opening  is  completely  open.  Trim  approx..  6mm  of  insulation  from  the 
speaker wire and twist the copper ends. Insert the speaker wires into the 
connector and tighten the set screws. Connect Amp to S and 
Amplifier - to Speaker – using the terminals shown. Make sure the Bridged 
switch is set to YES. Repeat for the remaining zones 

Summary of Contents for eZi-DA66

Page 1: ...eZi DA66 Installation Manual Revision 1 2 Page 1 Professional Multi Room 6 Source 6ZoneAudio System User and Installation Manual Home Audio Distribution System eZi DA66 eZi DA66...

Page 2: ...D WIRING 9 KEYPAD CABLE INFORMATION 10 INSTALLATION OF KEYPAD HUB EARTH 10 INSTALLATION OF KEYPAD HUB CAT5 10 SPEAKER INSTALLATION IMPORTANT 11 SPEAKER INSTALLATION STEREO MODE SPEAKER INSTALLATION BR...

Page 3: ...this device 7 Unplug the unit during lightning storms or when the unit will be unused for a long period of time 8 Do not allow the power cords to be walked on pinched tripped over or otherwise damage...

Page 4: ...in a safe place for future reference PACKAGE CONTENTS After receiving the product please inventory the contents to ensure you have all the parts listed below If anything is missing or damaged please c...

Page 5: ...s with 3 x Multizone Controller systems RS232 Control eZi UHAP or MZC emulation Dual Voltage Selector MUST BE 230V 12 high quality amplifiers with 50 watts output power 4ohms or 100 watts 8ohms in bri...

Page 6: ...also sends IR commands to the Multizone Controller master controller IR output jacks for remote control of your source components No programming necessary just touch the keypad and start playing music...

Page 7: ...66 Installation Manual Revision 1 2 Page 7 INFRARED REMOTE CONTROL Infrared IR emitter Zone power on off Bass up down Balance right Zone mute Source selection 1 6 Treble up down Volume up down Balance...

Page 8: ...onnectors for all Multizone Controller keypads 5 The Multizone Controller includes a central keypad hub All Multizone Controller keypads will be home run back the hub Keep the hub close the Multizone...

Page 9: ...can damage the keypad Use a good quality Cat5e 6 cable and crimp RJ45 jacks on each end of the cables The RJ45 jack plugs into the back panel of the keypads and the 6 x RJ45 jacks on the keypad hub T...

Page 10: ...e Keypad Hub and the other end of the fly lead to an earth point Please ensure that the earth connection is tested to the earth of the installation without a reliable earth connection the energy gener...

Page 11: ...terminal block connectors are removable Remove the terminal block connector and make sure that all connections are open by turning each set screw counter clockwise This insures that the speaker wire o...

Page 12: ...o the 6 x zone outputs PRE AMP outputs can be used to connect powered subwoofers to a zone or additional amplifiers to expand the available power in a large zone or multiple zones The eZi DA66 Control...

Page 13: ...bles to connect sources to the Multizone Controller and keep RCA cables as short as possible to avoid RF interference INFRARED EMITTER OUTPUTS This system has the ability to repeat IR signals from eac...

Page 14: ...orresponding zone sends 12VDC to the trigger output jack When the zone is powered OFF the routed 12VDC signal is disengaged Triggers can be used to automatically power peripheral equipment ON OFF with...

Page 15: ...ll be the Master device Slide the Master Slave switch on this unit to the Master position 2 Plug one end of the included ribbon cable into the Expansion Output port on the back of the Master device Pl...

Page 16: ...nstructions SPECIFICATIONS RMS Power 8Ohms 25 watts x 12 Trigger Systems ON Voltage 12v DC RMS Power 4Ohms 50 watts x 12 Trigger External Mute Voltage 12v DC RMS Power 8 Ohms Bridged 100 watts x 6 Inf...

Reviews: