RECOMMENDED PERIODIC MAINTENANCE
1. Remove Release Plate Screws (b) with 1/8” hex key.
2. Remove hex Hammer assembly using a 5/16” (8 mm)
wrench
3. The Firing Pin (j) can then be removed through the same
opening the Hammer Assembly was removed from.
4. Thoroughly clean all parts and lubricate with light oil and
reassemble in reverse order of disassembly.
5. Test for free movement of hammer, release plate, and
actuator pin.
INFORMATION, SPARE PARTS & ACCESSORIES
Go to the website below or for further information on your MICRO-
BLASTER . Spare parts can be obtained from your MICRO-BLASTER
dealer. Units needing repair will only be accepted after proper return
authorization has been given by EZEBREAK.
www.ezebreak.com
EZEBREAK
304-497-9970
CRACK WISELY!