Autofill Controls

Bathtub Filling
Start the automatic bathtub filling process by 
pressing the “bathtub filling symbol” (4) to the left 
of the thermostat (2). The green light (30) will be 
lit and water will fill the bathtub.

The red “running water” light (31) to the right of 
the thermometer indicates that the thermometer 
shows the filling water temperature and can be 
adjusted by turning the thermostat knob (2).

When the water level reaches the “waterline” inside 
the bathtub, (about 53 gallons, 200 liters) the 
bathtub filling will automatically stop and both the 
green (30) and the red light (31) will switch off.

The light (33) automatically indicates that 
the thermometer shows the still bathtub water 
temperature.

More water can be added into the bathtub. When 
pressing the “bathtub filling symbol” (4) once more, 
the green light (30) will flash and water will be 
added for approximately one minute.

This procedure can be repeated or stopped by 
pressing the “bathtub filling symbol” (4).

WARNING:  Always physically check water 
temperature before and during bathing/showering 
to ensure that the thermoscopic mixer (2) is 
functioning.

Showering
Remove the shower handle (11) from the panel and 
hold it over the bathtub away from the patient.

Press the “shower handle symbol” (9) to the right of 
the thermostat. The green light (32) will illuminate 
and water will spray from the shower handle.

The red “running water” light (31) to the right of 
the thermometer indicates that the thermometer 
shows the running shower water temperature and 
can be adjusted by turning the thermostat knob.

Stop the water flow by pressing the “shower handle 
symbol” (9) once. Both the green (32) and the red 
(31) lights will switch off. The procedure can be 
repeated.

The shower water flow is preset when installing the 
bathtub. If other shower flows are required, set the 
water flow by adjusting the black ball valve inside 
the panel.

Whirlpool
To start the whirlpool system, press the whirlpool 
symbol (20) and the green light (34) will be lit. 
To stop the whirlpool system, press the whirlpool 
symbol (20) and the green light (34) will switch off.

Important: Never start the whirlpool when the 
water level is below the jet (21). Read separate 
whirlpool instructions.

Summary of Contents for EZ 900 Series

Page 1: ...Form 2 202 Rev 7 31 18 EZ 900 Bathtubs Operator s Instructions EZ Way Inc PO Box 89 Clarinda IA 51632 1 800 627 8940 www ezlifts com WARNING Cancer and Reproductive Harm www P65Warnings ca gov...

Page 2: ...If you have any questions regarding the operation or maintenance of your bathing system and cannot find the answer in this manual please contact us at 1 800 627 8940 The system is designed for years...

Page 3: ...ox to the panel by removing the back of the panel and use the transport wheel beam B and wooden ramp L 4 1 C if ordered to unload off pallet The transport wheel beam can also be used to transport the...

Page 4: ...atient showering 10 Patient shower hose 11 Patient shower handle 12 Handle bracket Cleaning System C Position Description 13 Shut off safety valve 14 Spray equipment hose 15 Spray handle 16 Spray hand...

Page 5: ...eck water temperature before and during bathing showering to ensure that the thermoscopic mixer 2 is functioning Showering Remove the shower handle 11 from the panel and hold it over the bathtub away...

Page 6: ...patient shower 9 The thermometer 3 measures bathtub filling water and patient shower temperature in C The temperature probe is located close to the thermoscopic mixer 2 to provide an accurate reading...

Page 7: ...the thermoscopic mixer 2 to desired temperature 4 Physically test water temperature and adjust thermoscopic mixer 2 to suit Adjust water flow with shutoff valve 9 located on front of control panel 5 S...

Page 8: ...osition Avoid placing the jet in a full upward position as this could cause the water to splash 4 With the patient in the bathtub turn on the whirlpool unit by pushing the ON OFF control button 20 on...

Page 9: ...nsure that the thermoscopic mixer 2 is functioning Ambulatory Patient Transfer For patient comfort and safety we recommend that ambulatory patients are transferred directly into the prefilled tub on E...

Page 10: ...t all times For further details refer to the EZ Mobile Bath Lift System operator s manual Patient Handling Patient Transfer into Tub with EZ Mobile Bath Lift System While sitting safely secured patien...

Page 11: ...th maximum 4 1 3 cups 1 5 liter of concentrated detergent WARNING Avoid skin or eye contact with cleaning detergent which can be highly corrosive If contact is made rinse immediately with excess water...

Page 12: ...yellow adapter 19 placed on top of the detergent filling lid 18 to the whirlpool inlet 24 4 Remove cleaning shower handle 15 from yellow cleaning hose 14 by pressing the dots on the quick coupling 5...

Page 13: ...tch the gel coat finish of the fiberglass bathtub and the panel When the tub is not in use lower it to its lowest position and make sure all valves are closed Clean the strainers on the patient and cl...

Page 14: ...volts 60 Hz 16 Amps Permanent connection installed by others Please note All electrical conduit fitting and wire to bath is to be supplied and installed by your professional electrician in accordance...

Page 15: ...Floor Drainage Mount the bracket for the drainage pipe to the front of the panel Adjust by cutting the length of the pipe Wall Drainage Mount the bracket for the drainage pipe to the back of the pane...

Page 16: ...900 HCW Installation Drawing 3 1 2 2 1 2 WALL DRAINAGE FLOOR DRAINAGE MIN 10 17 3 4 1 1 2 MIN 1 11 3 4 MAX 3 3 1 3 MIN 3 7 3 4 MAX 4 11 1 2 WALL 16...

Page 17: ...17 900 FCW Installation Drawing 3 1 2 2 1 2 WALL DRAINAGE FLOOR DRAINAGE MIN 10 17 3 4 1 1 2 2 8 4 4 WALL...

Page 18: ...Installation Drawing 2 8 3 4 1 7 1 2 4 8 1 9 1 2 2 3 1 3 2 3 4 2 3 1 2 2 8 3 4 7 7 1 2 4 3 2 1 3 4 1 9 3 3 4 8 5 1 2 6 1 4 2 18...

Page 19: ...19 Wiring Diagram...

Page 20: ...Wiring Diagram 20...

Page 21: ...nconvenience or incidental or consequential damages occasioned by the use loss of use or misuse of the products or by the failure of the products to conform to the warranty set forth above This warran...

Reviews: