background image

13

Cleaning the Adjustable Whirlpool Jet (21)
Cleaning the jet:  Turn the “jet friction housing” 
counter clockwise 90° and pull it out. Clean the jet 
and the housing.

Cleaning the valve housing:  Remove by lifting the 
two hooks (inside the housing) and pull it out.

Cleaning the valve (inside):  Turn it counter-
clockwise and pull out.

Cleaning the Screen (23)
Remove the whirlpool inlet safety screen by turning 
it counter clockwise.

WARNING:  Avoid shin or eye contact with 
detergent, which is highly corrosive. If contact 
is made, rinse immediately with excess water. If 
irritation occurs, consult a medical doctor. Always 
read and follow label directions carefully.

Routine Maintenance

Daily Maintenance

• 

Clean the tub after every use.

• 

Check the cleaning supply at least daily, 
depending on the frequency of use.

• 

Avoid abrasive cleaners which may scratch the gel 
coat finish of the fiberglass bathtub and the panel.

• 

When the tub is not in use, lower it to its lowest 
position and make sure all valves are closed.

• 

Clean the strainers on the patient and cleaning 
shower handles by rubbing it with your thumb.

• 

Visually inspect the tub interior to make sure 
there are no nicks or cracks which may scratch the 
patient.

Please note:  Iodine, bromine, and methylene blue 
can discolor the fiberglass.

The recommended frequency of these maintenance 
procedures will depend on the hardness of your 
water supply and how often the equipment is used. It 
is good practice to establish these routine procedures 
on a weekly basis and then adjust the frequency as 
your conditions indicate.

All mechanical parts inside the bathtub panel are 
maintenance free.

WARNING:  The equipment must not be used 
in any way that varies from the safety precautions 
and operating procedures detailed in this manual.

The equipment must not be operated by anyone 
until the user has read and understands the 
operating manual.

Summary of Contents for EZ 900 Series

Page 1: ...Form 2 202 Rev 7 31 18 EZ 900 Bathtubs Operator s Instructions EZ Way Inc PO Box 89 Clarinda IA 51632 1 800 627 8940 www ezlifts com WARNING Cancer and Reproductive Harm www P65Warnings ca gov...

Page 2: ...If you have any questions regarding the operation or maintenance of your bathing system and cannot find the answer in this manual please contact us at 1 800 627 8940 The system is designed for years...

Page 3: ...ox to the panel by removing the back of the panel and use the transport wheel beam B and wooden ramp L 4 1 C if ordered to unload off pallet The transport wheel beam can also be used to transport the...

Page 4: ...atient showering 10 Patient shower hose 11 Patient shower handle 12 Handle bracket Cleaning System C Position Description 13 Shut off safety valve 14 Spray equipment hose 15 Spray handle 16 Spray hand...

Page 5: ...eck water temperature before and during bathing showering to ensure that the thermoscopic mixer 2 is functioning Showering Remove the shower handle 11 from the panel and hold it over the bathtub away...

Page 6: ...patient shower 9 The thermometer 3 measures bathtub filling water and patient shower temperature in C The temperature probe is located close to the thermoscopic mixer 2 to provide an accurate reading...

Page 7: ...the thermoscopic mixer 2 to desired temperature 4 Physically test water temperature and adjust thermoscopic mixer 2 to suit Adjust water flow with shutoff valve 9 located on front of control panel 5 S...

Page 8: ...osition Avoid placing the jet in a full upward position as this could cause the water to splash 4 With the patient in the bathtub turn on the whirlpool unit by pushing the ON OFF control button 20 on...

Page 9: ...nsure that the thermoscopic mixer 2 is functioning Ambulatory Patient Transfer For patient comfort and safety we recommend that ambulatory patients are transferred directly into the prefilled tub on E...

Page 10: ...t all times For further details refer to the EZ Mobile Bath Lift System operator s manual Patient Handling Patient Transfer into Tub with EZ Mobile Bath Lift System While sitting safely secured patien...

Page 11: ...th maximum 4 1 3 cups 1 5 liter of concentrated detergent WARNING Avoid skin or eye contact with cleaning detergent which can be highly corrosive If contact is made rinse immediately with excess water...

Page 12: ...yellow adapter 19 placed on top of the detergent filling lid 18 to the whirlpool inlet 24 4 Remove cleaning shower handle 15 from yellow cleaning hose 14 by pressing the dots on the quick coupling 5...

Page 13: ...tch the gel coat finish of the fiberglass bathtub and the panel When the tub is not in use lower it to its lowest position and make sure all valves are closed Clean the strainers on the patient and cl...

Page 14: ...volts 60 Hz 16 Amps Permanent connection installed by others Please note All electrical conduit fitting and wire to bath is to be supplied and installed by your professional electrician in accordance...

Page 15: ...Floor Drainage Mount the bracket for the drainage pipe to the front of the panel Adjust by cutting the length of the pipe Wall Drainage Mount the bracket for the drainage pipe to the back of the pane...

Page 16: ...900 HCW Installation Drawing 3 1 2 2 1 2 WALL DRAINAGE FLOOR DRAINAGE MIN 10 17 3 4 1 1 2 MIN 1 11 3 4 MAX 3 3 1 3 MIN 3 7 3 4 MAX 4 11 1 2 WALL 16...

Page 17: ...17 900 FCW Installation Drawing 3 1 2 2 1 2 WALL DRAINAGE FLOOR DRAINAGE MIN 10 17 3 4 1 1 2 2 8 4 4 WALL...

Page 18: ...Installation Drawing 2 8 3 4 1 7 1 2 4 8 1 9 1 2 2 3 1 3 2 3 4 2 3 1 2 2 8 3 4 7 7 1 2 4 3 2 1 3 4 1 9 3 3 4 8 5 1 2 6 1 4 2 18...

Page 19: ...19 Wiring Diagram...

Page 20: ...Wiring Diagram 20...

Page 21: ...nconvenience or incidental or consequential damages occasioned by the use loss of use or misuse of the products or by the failure of the products to conform to the warranty set forth above This warran...

Reviews: