background image

1. Information

*The  factory default programming password
   is *1234, this is NOT the PIN number.
*In the programming mode you can set up to 40 groups  of 4-digit PIN numbers to unlock.
* 30 Groups have adjustable unlock time and 10 are fixed on a momentary pulse.

2. Modify the programming password

1) Switch off the power then press and hold the * button, switch on the power. After a continuous alarm is heard then release the button.
2) The continuous alarm will now stop. Now enter a new 4 digit programming password.
3) Another long Di sound will be heard, it indicates modifying is successful.
3) Press * to exit the programming mode.

3. Enter the programming mode

From standby press * a Di sound will be heard now enter the 4 digit programming password 

(Default is *1234)

.

A long Di sound will  be heard to indicate that the keypad has entered programming successfully.

The keypad will timeout of the programming mode after 30 seconds of idle state or you can press * to exit to standby.

4. Setting the unlock time

Factory default unlock time is 1 second.

1) Enter  the programming mode 

(Default is *1234)

 .

2) Press 00 then a long Di sound will be heard,
3) Enter the unlock time in seconds (from 01-99) then another long Di sound can be heard. This indicates setting successfully.
3) Press * to exit the programming mode.

5. Add user PIN codes

1) Enter  the programming mode 

(Default is *1234)

 .

2) Enter a 2 digit user number from 01-40 a long Di sound will be heard.
3) Press 4 digits (can be 2-6 digits) password then another long Di sound will be heard this indicates adding was successful.
4) Press * to exit the programming mode.

Position 01-30 are for a latching time or a momentary pulse.

NOTE: 

Position 31-40 are for a momentary pulse only.

6. Delete user PIN codes by user number

1) Enter  the programming mode 

(Default is *1234)

.

2) Enter the 2 digit user number (from 01-40) a long Di sound will be heard
3) Press * to confirm, another long Di sound can be heard this indicates the deleting is successful.
3) Press * to exit the programming mode

.

7. Delete user PIN codes by PIN

1) Enter the programming mode 

(Default is *1234)

.

2) Press # then you will hear a DiDi sound enter the PIN you wish to delete, a long Di sound can be heard to indicate a successful delete.
3) Press * to exit the programming mode.

8. Factory Default Settings (Partial)

1). Enter  the programming mode 

(Default is *1234)

.

2). Press #, when a DiDi sound is heard, press # again a long Di 
      Sound can be heard
3) Press # for 7 times  after 3 seconds another long Di sound will be heard it indicates deleting successful.
4) Press * to exit the programming mode.
- Unlock time will be restored to 1 second.
- User PIN numbers will be deleted
- Programming password and digit length will remain the same.

9. Factory Default Settings (button type keypad) (Full)

1) Switch off the power then press and hold #.
2) Whilst holding # switch on the power.
3) A continuous alarm will be heard, now release # and after 3 seconds a long Di sound will be heard.
- Unlock time will be restored to 1 second.
- User PIN numbers will be deleted
- Programming password will revert to 1234
- Password and PIN number length will return to the 4 digit default.

10

Factory Default Settings (touch type keypad) (Full)

1) Switch off the power.
2) Switch on the power.
3) Hold down the # key within 2 seconds of powering on.
4) A continuous alarm will be heard, now release # and after 3 seconds a long Di sound will be heard.
- Unlock time will be restored to 1 second.
- User PIN numbers will be deleted
- Programming password will revert to 1234
- Password and PIN number length will return to the 4 digit default.

  

Page 13

Keypad Setup Guide

Summary of Contents for EV-H298

Page 1: ...4 Wire Video Intercom System with Net link EV H7 EV H298KP EV H298FKP EV H304KP EV H304 4B EV H304FKP EV H304F 4B EV H298 Eyevisi n Net Link Eyevisi n Eyevisi n Eyevisi n Eyevisi n Eyevisi n Eyevisi n...

Page 2: ...it with netlink Page 10 Home System Wiring cont Two indoor to two outdoor units with netlink Four indoor to two outdoor units without netlink Page 11 Home System Wiring cont Four indoor to two outdoor...

Page 3: ...wet areas high temperature dust caustic and oxidation gas in order to avoid any unpredictable damage Every installation may vary slightly according to the user s requirements The recommended height fo...

Page 4: ...th 1 5mm Pair up to 200m Eyevisi n System jumper settings Remove the RING jumper J1 from the NETLINK only to eliminate a dual ringing tone on the outdoor unit There is no need to remove the ring jumpe...

Page 5: ...cm If the door station is mounted to low the camera may fail in seeing the guests face and will also present issues for communication Page 3 DC AC OUT OUT Standard 12V Power Adapter Max distance is 3m...

Page 6: ...rcom Line 3 Red B Intercom Line 4 Yellow Video Unlock Line 5 Green Relay N O Unlock Line 6 White Relay COM Intercom Line 1 Blue Audio Intercom Line 2 Black GND Intercom Line 3 Red B Intercom Line 4 Ye...

Page 7: ...Electric Striker Connection Fail Secure Power on to unlock Electric Striker Connection Fail Safe Power off to unlock Page 5 H298KP Front Rear View H298FKP Front Rear View LED Light LED Light Camera C...

Page 8: ...ack GND Black GND Black GND Standard Power Adapter Standard Power Adapter Standard Power Adapter 1 2 3 1 2 3 1 2 3 1 2 3 4 1 2 3 4 1 2 3 4 CN 3 1 12V 2 Negative GND CN 2 1 NO Exit Button 2 Button Comm...

Page 9: ...B Front Rear View H304F 4B Front Rear View LED Light LED Light Camera Camera Speaker Speaker Call Buttons Call Buttons Microphone Microphone Screw System Wiring Rain Cover Screws Plastic wall plug Rai...

Page 10: ...Note Only apartments requiring this feature require a netlink Monitor Expansion Each apartment requiring additional monitor s has the ability to do so with an expandability of up to FOUR monitors per...

Page 11: ...pter 12V Adapter 2C 2C Netlink Netlink CN 1 CN 1 CN 3 CN 3 CN 2 CN 2 12V Adapter 12V Adapter Door Striker or Auto Gate Door Striker or Auto Gate Keypad Door Stations Only Keypad Door Stations Only 2C...

Page 12: ...dapter 12V Adapter 2C 2C 2C 2C CN 1 CN 1 CN 1 CN 1 CN 1 CN 1 CN 2 CN 2 CN 2 CN 2 12V Adapter 12V Adapter 2C 2C Netlink Netlink CN 1 CN 1 CN 3 CN 3 CN 2 CN 2 12V Adapter 12V Adapter 12V Adapter 12V Ada...

Page 13: ...CN 2 CN 2 12V Adapter 2C Netlink CN 1 CN 3 CN 2 12V Adapter 12V Adapter Door Striker or Auto Gate Door Striker or Auto Gate Keypad Door Stations Only Keypad Door Stations Only 2C 2C 2C 2C Wiring Layou...

Page 14: ...Answering Visitor Calls Monitoring Transferring the Call Page 12...

Page 15: ...a momentary pulse only 6 Delete user PIN codes by user number 1 Enter the programming mode Default is 1234 2 Enter the 2 digit user number from 01 40 a long Di sound will be heard 3 Press to confirm a...

Page 16: ...ation The default setting is intercom enabled home mode which is not suitable for apartments Press and hold the unlock key on the monitor til a long beep is heard this confirms the unit is in apartmen...

Page 17: ...ect to confirm you have read the terms and conditions 8 Press the Submit button and a registration success message will appear 9 You will then see the login screen 10 Press the Login button to log int...

Page 18: ...g the preliminary hard reset see above GOTO the WiFi settings on your phone tablet and connect to the network named LIDAW you will be prompted there is no internet connection available on this network...

Page 19: ...he button Hotspot Connection On the following screen press Next 4 Choose the Doorbell 1 Type 1 option Do not change the GID number Do not change the GID number Username is admin Password is 1234 Name...

Page 20: ...ock password default is 1234 1 From the home screen within the APP press the icon 2 Locate the One Key Unlock option and press the highlighted icon to enable it The icon will turn green 3 Enter the un...

Page 21: ...que GID number the username admin and the default password of 1234 or the new password if already configured by WiFi 7 Press button in the upper right Save Page 19 Problems requiring Preliminary setup...