EYE-LCD-4600/5500-LE-700
75
Appendix : RS232 Protocol
RS232 Command Format
•
STX(1byte) + IDT(1byte) + Type(1byte) + CMD(3bytes) + [Value/
Reply(1byte)] + ETX(1byte)
•
STX : Start byte = 07
•
IDT : 01~19 (Hex Num) for single control mode. 00 (Hex Num) for broadcast
mode (Only for Video Wall).
•
Type : Read or Write command, 01: read, 02: write; 00: return to host (from
monitor)
•
CMD : as following tables
•
Value : Setting Value of “Write Command”
•
Reply : Return Value of monitor
•
ETX : End byte = 08
Transmit from PC (Host)
Read/Action command : 07 IDT 01 CMD 08 (7bytes)
Write/Setting command : 07 IDT 02 CMD VAL 08 (8bytes)
Return from Monitor:
Return CMD is the same with received CMD, the return command will be sent
after action.
Serial Port Setting
Baud Rate
Data Bit
Parity Bit
Stop Bit
115200
8
None
1
Baud rate can set to 38400, 19200, 9600 to match the monitor baud rate
setting.
Baud rate 115200 is the default setting.
Explanation of symbols
●
: Optional commands for advanced A/D board option
▲
: Valid command on Power saving / off mode
Main
Item
Control
Item
CMD
Type
Value
(DEC)
Reply (DEC)
Content
CMD
(HEX)
Remark
Power Control and Input Source
Power Control
POW
W/R
00
00
Off (soft power)
50 4F 57
▲
01
01
On (soft power)
▲
Input Source
MIN
W/R
00
00
VGA
4D 49 4E
01
01
Digital DVI
02
02
S-Video
03
03
Composite 1
04
04
Component 1
05
05
HDSDI 1
●
06
06
HDSDI 2
●
09
09
HDMI 1
10
10
HDMI 2
13
13
DisplayPort
Summary of Contents for eyeLCD-4600-LE-700
Page 64: ...EYE LCD 4600 5500 LE 700 64 APPENDIX DIMENSIONS EYE LCD 4600 LE 700 ...
Page 65: ...EYE LCD 4600 5500 LE 700 65 APPENDIX DIMENSIONS EYE LCD 5500 LE 700 ...
Page 69: ...EYE LCD 4600 5500 LE 700 69 Appendix Wall Mount Safety Notes ...
Page 70: ...EYE LCD 4600 5500 LE 700 70 ...
Page 81: ...Notes Notizen ...