B
Network and Power Injector Connector
(see
figure 5
)— is on the right side of the
recessed area.
Connect the touchpanel to the LAN using a twisted pair cable, terminated with an RJ-45
connector. Use a straight-through Ethernet cable to connect the panel to a switch or router.
Use a crossover cable to connect the panel directly to a computer.
An Extron IPL Pro Control Processor must also be connected to the same network domain
as the TouchLink Pro touchpanel. See the
www.extron.com
for a list of suggested models.
The network port has two LEDs. The green LED lights steadily to indicate that the
touchpanel is connected correctly to a network. The yellow LED flashes to indicate that data
is being passed to or from the touchpanel.
The connector can also be used with a PoE power injector (not provided).
ATTENTION:
•
The touchpanels can use a 12 VDC desktop power supply and is also Power
over Ethernet (PoE 802.3af, class 3) compliant. Do not connect either power
supply before reading the Attention notifications on
page 10
or
page 12
.
•
Les écrans tactiles peuvent utiliser une source d’alimentation externe 12 Vcc, et
sont également compatible avec l’alimentation POE via Ethernet (PoE 802.3af,
classe 3). Ne branchez pas de sources d’alimentation externes avant d’avoir lu
les mises en garde dans la section « Power Supply » sur
page 10
ou
page 12
.
To use a PoE power injector
— connect a straight-through Ethernet cable to the power
supply and a switch or router. This cable carries network information from the switch or
router to the power supply input. A second straight-through cable carries the network
information and 48 VDC from the power supply to the touchpanel. Connect the IEC power
cord to a convenient 100 VAC to 240 VAC, 50-60 Hz power source.
The figure below shows the Extron XTP PI 100. Your power injector may look different.
100-240V
~
50-60Hz
0.4A MAX
XTP
PWR
XTP PWR
To network switch
To touchpanel
Figure 7.
Connecting the Power Injector
CAUTION:
Risk of Explosion
if the battery is replaced by an incorrect type. Dispose
of used batteries according to the instructions.
ATTENTION
:
Risque d’explosion.
Ne pas remplacer la pile par le mauvais type de
pile. Débarrassez-vous des piles utilisées selon le mode d’emploi.
TLP Pro 720 Series and TLP Pro 1020 Series • Panel Features