background image

 

9

Product Category

Without a wall box

If the wall box is not required by local building codes, you can mount the touchpanel directly into drywall. 

1. 

Use the mounting plate as a template to mark the wall or download the cut-out template for your product from 

www.extron.com

. Place the template or mounting plate against the wall or furniture in a suitable location and ensure that it 

is level. 

2. 

Mark the position of the hole and cut the wall.

• 

For the TLC Pro 526M, this hole is 2.4 inches (61 mm) wide x 2.1 inches (53 mm) high.

• 

For the TLC Pro 726M or 1026M, this hole is 3.5 inches (89 mm) wide x 2.0 inches (51 mm) high.

3. 

Mark the slots labeled WALL (TLC Pro 526M) or MK (TLC Pro 726M or 1026M) (figure 13) and drill the two pilot holes. Extron 
recommends using two Molly bolts or SnapToggle bolts.

4. 

Secure the mounting plate to the wall (see 

figure 13

2

, on the previous page).

5. 

Complete the installation as described in 

steps 3 through 7

 on the previous page.

NOTE:

 

Allow adequate space to accommodate the USB adapter:

• 

For the TLC Pro 526M series, allow a minimum of 1.00" (26 mm) behind the mounting plate.

• 

For the TLC Pro 726M series, allow a minimum of 1.37" (35 mm) behind the mounting plate.

• 

For the TLC Pro 1026M series, allow a minimum of 1.40" (36 mm) behind the mounting plate.

Reset Modes: a Brief Summary

The TLC Pro Control System Series offers the following reset modes:

• 

Use factory firmware:

Press and hold the 

Reset

 button (

figure 2

B

, on page 3) while applying power to the 

unit. Use this mode to replace firmware in the event of firmware failure.
Do not continue to operate the TouchLink Pro control system using the factory firmware 
version. If you want to use the factory default firmware version, you must upload that version 
again.

• 

Project Recovery:

This mode is activated using Global Configurator Plus and Professional. See the 

Global Configurator Help File

 for more information.

• 

Run/Stop Program:

Hold down the 

Reset

 button for about 3 seconds, until the Power LED blinks once. Release 

and press the 

Reset

 button momentarily (for <1 second) within 1 second. (Nothing happens if 

the momentary press does not occur within 1 second.) The LED blinks 2 times if the program 
is starting. The LED blinks 3 times if the program is stopping. This mode allows you to restart 
any programs stopped by an IP settings reset.

• 

Toggle DHCP Client:

This mode toggles between DHCP enabled and DHCP disabled. Press the 

Reset

 button 

five times, consecutively. After the fifth press, do not press the button again within 3 
seconds. 
If DHCP was enabled, it is now disabled and the Reset LED (

figure 2

C

)

 blinks three 

times. 
If DHCP was disabled, it is now enabled and the Reset LED blinks six times.

NOTES:

• 

DHCP toggle mode is supported on firmware version 3.0 or higher.

• 

By default DHCP is off and the unit uses a static IP address.

• 

When you disable the DHCP client, the unit reverts to using the previously-set 
static IP address.

• 

Reset All IP Settings:

Press and hold the 

Reset

 button for 6 seconds. After the Reset LED flashes twice, release 

and momentarily press the 

Reset

 button. Use this mode to reset all network settings without 

affecting user-loaded files.

• 

Reset to Factory Defaults:

Press and hold the 

Reset

 button for 9 seconds. After the Reset LED flashes three times, 

release and momentarily press the 

Reset

 button. Use this mode to return the interface to 

factory default settings.

NOTE:

  The factory configured passwords for all accounts on this device have been set to 

the device serial number. If the device is reset to factory defaults, the password reverts 
to 

extron

. Passwords are case sensitive.

Summary of Contents for TLC Pro 526M Series

Page 1: ...rk information from your network administrator DHCP status on or off If DHCP is off you will also require IP address Subnet mask Gateway User name this can be either admin or user Password the factory configured passwords are the serial number of the touchpanel for either admin or user NOTE The factory configured passwords for all accounts on this device have been set to the device serial number I...

Page 2: ... motion between three to five feet from the touchpanel and at least 15 from the center axis When no motion has been detected for a user defined period of time the touchpanel enters sleep mode When motion is detected by the sensor the screen display is restored and active B Communication LED Shows the configuration and connection status of the touchpanel Unlit during normal operation the TouchLink ...

Page 3: ... E E F F G G D D D D K K D D D D I I J J TLC Pro 1026M L L e TLC Pro 526M with USB Adapter in Place A Menu Button on next page B Reset Button on next page C Reset LED on next page D Mounting Slots on next page E Digital Input Monitoring Port on next page F LAN PoE Connector on next page G USB Port on next page H Speaker on next page I Mounting Plate Slot on next page J Mounting Screw on next page ...

Page 4: ...without a power injector The power injector must be purchased separately Extron recommends the Extron XTP PI 100 power injector see figure 3 Your power injector may look different 100 240V 50 60Hz 0 4A MAX XTP PWR XTP PWR To network switch To touchpanel Figure 3 XTP PI 100 Power Injector G USB Port Compatible with USB 2 0 H Speaker Provides audible feedback for the user TLC Pro 526M a single speak...

Page 5: ...d of the emitter over or next to the IR signal pickup window of the device being controlled Connect two wires to the IR port as shown in figure 6 If both the IR port and contact closure port are used the ground pin must be shared by both devices NOTE Each emitter must be within 100 feet 30 4 meters of the TLC Pro control system for best IR control results S G IN IR C IN To the IR Receiver of a Pro...

Page 6: ...y or odd parity default no parity This port supports flow control The default is no flow control NOTE The maximum distance from the touchpanel to the device being controlled is usually 200 feet 61 m but this can vary depending on factors such as cable gauge baud rates environment and output levels from the touchpanel and the device being controlled To wire the ports see figure 11 If single port is...

Page 7: ... be wall mounted either using a UL listed junction box an external wall box or directly into drywall or furniture Suitable mounting accessories can be found at www extron com ATTENTION Do not install touchpanels in a fire resistant rated wall or partition assembly Ne pas installer les écrans tactiles sur un mur protégé par un dispositif coupe feu ou dans une cloison All structural steps and electr...

Page 8: ...has two hooks one in each top corner The TLC Pro 726M and TLC Pro 1026M mounting plate has four hooks 3 one in each corner see figure 14 below Position the touch panel so that the mounting slots see figure 2 D on page 3 in the rear of the touchpanel align with these hooks 6 Move the touchpanel inward and downward so that touchpanel sits securely on the hooks and the tongue at the bottom of the mou...

Page 9: ...e version you must upload that version again Project Recovery This mode is activated using Global Configurator Plus and Professional See the Global Configurator Help File for more information Run Stop Program Hold down the Reset button for about 3 seconds until the Power LED blinks once Release and press the Reset button momentarily for 1 second within 1 second Nothing happens if the momentary pre...

Page 10: ...2 A on page 3 Figure 15 shows the TLC Pro 526M menu The setup menus for the other touchpanels are very similar There are five different screens Status shown in figure 15 Network Display Audio and Advanced The screens can be selected by pressing the appropriate button in the navigation bar at the top of the screen for more information see the TLC Pro 526M 726M and 1026M User Guide Status Display Au...

Reviews: