TLC Pro 526M, 726M and 1026M Series • Setup Guide

Overview

The Extron TLC Pro 526M, TLC Pro 726M, and TLC Pro 1026M are wall mounted capacitive TouchLink

®

 Pro control systems that 

combine a touchpanel with an internal control processor.

• 

The TLC Pro 526M series touchpanels have a 5-inch screen with a 800x480 resolution and 24-bit color depth.

• 

The TLC Pro 726M series touchpanels have a 7-inch screen with a 1024x600 resolution and 24-bit color depth.

• 

The TLC Pro 1026M series touchpanels have a 10.1-inch screen with a 1280x800 resolution and 24-bit color depth.

Each model has a USB adapter with control ports that can be configured by Extron software. The Touchlink Pro control system 
acts as an all-in-one module combining touchpanel asthetics with the internal control processor, eliminating the need for an 
external control processor. This guide provides instructions for experienced installers to mount and install these touchpanels.

Setup Checklist

Get Ready

 

…

Download and install the latest version of the following software:

 

…

GUI Designer

 — for designing layouts for Extron TouchLink

®

 Pro touchpanels and third party touch interfaces.

 

…

Global Configurator

®

 Plus and Professional (GC) 

— for configuring the control system.

 

…

Toolbelt

 — for discovering the control products on the network, for managing core settings, and for upgrading firmware 

when needed. 

NOTE:

  All three software programs are available from 

www.extron.com

.

 

…

IP Link Pro Device Drivers

 — to allow the control ports to interact with the devices they are controlling.

 

…

Obtain the following network information from your network administrator:

 

…

DHCP status

 (on or off). If DHCP is off, you will also require

 

…

IP address

 

 

…

Subnet mask

 

…

Gateway

 

…

User name

 — this can be either 

admin

 or 

user

.

 

…

Password

  — the factory configured passwords are the serial number of the touchpanel (for either admin or user).

NOTE:

  The factory configured passwords for all accounts on this device have been set to the device serial number. If the 

device is reset, the password reverts to 

extron

. Passwords are case sensitive.

 

…

Make a note of the touchpanel MAC address (see the rear panel label).

 

…

Obtain model names and setup information for the devices that will be monitored or controlled by the TouchLink Pro control 
system.

 

…

The TLC Pro Control System comes with a factory-installed Secure Sockets Layer (SSL) security certificate. To install a 
different SSL certificate, contact your IT department to obtain the certificate or for instructions on how to obtain one. See 
“Secure Sockets Layer (SSL) Certificates” in the 

TLC Pro 526M, 726M, and 1026M Series User Guide

.

 

…

IEEE 802.1X authentication is also supported once enabled (see “IEEE 802.1X Certificates” in the 

TLC Pro 526M, 726M and 

1026M Series User Guide

 for details).

Mount and Cable All Devices

 

…

Connect cables and power cords to the touchpanel and the USB adapter.

ATTENTION:

• 

Do not power on the touchpanels until you have read the Attention in the “Rear Panel Features” section of the 

TLC Pro 526M, 726M, and 1026M User Guide

.

• 

Ne branchez pas les écrans tactiles avant d’avoir lu la mise en garde dans la section « Rear Panel Features » du 

TLC Pro 526M, 726M, and 1026M User Guide

.

 

…

Connect control ports to the devices they are controlling or monitoring.

 

…

Mount the units. There are several mounting options for TLC Pro Control Systems (see 

Mounting

 on page 7). Once the 

unit is mounted, the rear panel is not accessible. Ensure all cables have been connected before mounting.

 

…

Power on all devices.

Summary of Contents for TLC Pro 526M Series

Page 1: ...rk information from your network administrator DHCP status on or off If DHCP is off you will also require IP address Subnet mask Gateway User name this can be either admin or user Password the factory configured passwords are the serial number of the touchpanel for either admin or user NOTE The factory configured passwords for all accounts on this device have been set to the device serial number I...

Page 2: ... motion between three to five feet from the touchpanel and at least 15 from the center axis When no motion has been detected for a user defined period of time the touchpanel enters sleep mode When motion is detected by the sensor the screen display is restored and active B Communication LED Shows the configuration and connection status of the touchpanel Unlit during normal operation the TouchLink ...

Page 3: ... E E F F G G D D D D K K D D D D I I J J TLC Pro 1026M L L e TLC Pro 526M with USB Adapter in Place A Menu Button on next page B Reset Button on next page C Reset LED on next page D Mounting Slots on next page E Digital Input Monitoring Port on next page F LAN PoE Connector on next page G USB Port on next page H Speaker on next page I Mounting Plate Slot on next page J Mounting Screw on next page ...

Page 4: ...without a power injector The power injector must be purchased separately Extron recommends the Extron XTP PI 100 power injector see figure 3 Your power injector may look different 100 240V 50 60Hz 0 4A MAX XTP PWR XTP PWR To network switch To touchpanel Figure 3 XTP PI 100 Power Injector G USB Port Compatible with USB 2 0 H Speaker Provides audible feedback for the user TLC Pro 526M a single speak...

Page 5: ...d of the emitter over or next to the IR signal pickup window of the device being controlled Connect two wires to the IR port as shown in figure 6 If both the IR port and contact closure port are used the ground pin must be shared by both devices NOTE Each emitter must be within 100 feet 30 4 meters of the TLC Pro control system for best IR control results S G IN IR C IN To the IR Receiver of a Pro...

Page 6: ...y or odd parity default no parity This port supports flow control The default is no flow control NOTE The maximum distance from the touchpanel to the device being controlled is usually 200 feet 61 m but this can vary depending on factors such as cable gauge baud rates environment and output levels from the touchpanel and the device being controlled To wire the ports see figure 11 If single port is...

Page 7: ... be wall mounted either using a UL listed junction box an external wall box or directly into drywall or furniture Suitable mounting accessories can be found at www extron com ATTENTION Do not install touchpanels in a fire resistant rated wall or partition assembly Ne pas installer les écrans tactiles sur un mur protégé par un dispositif coupe feu ou dans une cloison All structural steps and electr...

Page 8: ...has two hooks one in each top corner The TLC Pro 726M and TLC Pro 1026M mounting plate has four hooks 3 one in each corner see figure 14 below Position the touch panel so that the mounting slots see figure 2 D on page 3 in the rear of the touchpanel align with these hooks 6 Move the touchpanel inward and downward so that touchpanel sits securely on the hooks and the tongue at the bottom of the mou...

Page 9: ...e version you must upload that version again Project Recovery This mode is activated using Global Configurator Plus and Professional See the Global Configurator Help File for more information Run Stop Program Hold down the Reset button for about 3 seconds until the Power LED blinks once Release and press the Reset button momentarily for 1 second within 1 second Nothing happens if the momentary pre...

Page 10: ...2 A on page 3 Figure 15 shows the TLC Pro 526M menu The setup menus for the other touchpanels are very similar There are five different screens Status shown in figure 15 Network Display Audio and Advanced The screens can be selected by pressing the appropriate button in the navigation bar at the top of the screen for more information see the TLC Pro 526M 726M and 1026M User Guide Status Display Au...