![Extron electronics PVS 407D User Manual Download Page 63](http://html1.mh-extra.com/html/extron-electronics/pvs-407d/pvs-407d_user-manual_2457107063.webp)
PVS 407D • Connector Wiring
57
Terminating the Speaker Cable
To terminate the cable, strip the end of the cable 0.2 inch (5 mm) and secure the wires
into the supplied 4-pole captive screw connector as shown in figure 43.
PVS Switcher
Rear Panel
Speaker 1
Speaker 2
L
R
4/8
Ohms
AMPLIFIED OUTPUTS
4-pole Captive
Screw Connector
Audio output
to speakers
Speaker Wire
Color
To PVS 407D Terminal
(Left and Right)
Red
Positive (+)
Black
Negative (-)
Figure 43.
Wiring the Audio Output Connector
TP Cable Termination and Recommendations
Figure 44 details the recommended termination of both ends of TP cables with RJ-45
connectors in accordance with the
TIA/EIA T568B
wiring standard.
5
Pin
1
2
3
6
7
8
4
Wire Color
White-green
Green
White-orange
White-blue
Orange
White-brown
Brown
568A
Blue
12345678
RJ-45 Connector
Insert Twisted
Pair Wires
Pins:
Side View
Figure 44.
TP Cable Termination
ATTENTION:
•
The PoleVault signal transmission method is specific for PVS 407D switchers
working with PVT digital wallplates.
DO NOT
connect the input ports to an MTP
system or to an Ethernet/LAN or data transmission system
.
•
La méthode de transmission du signal PoleVault est spécifique pour les
sélecteurs PVS 407D qui fonctionnent avec les plaques murales PVT
numériques.
Ne PAS
connecter les ports d’entrée à un système MTP ou à un
système Ethernet/LAN ou de transmission de données.
43
44