Matrix Software, cont’d
MTPX Twisted Pair Matrix Switchers • Matrix Software
5-14
PRELIMINAR
Y
Using
Emulation
mode
When the progrm first opens (page 5-3), the Comm Port Selection window gives
you the option to select Emulation.
Emulation
mode allows you to set up the
software without attaching the switcher to the computer. To use
Emulation
mode,
do the following:
1.
Double-click the Matrix Switchers Control Program icon in the Extron
Electronics group or folder.
2.
Choose
Emulate
, and click
OK
.
3.
Choose an emulation file to open, and click
OK
. The file DEMO.MTX provides
a sample of a completed matrix setup. Selecting the file NEW.INI or clicking
Cancel
provides a blank setup to get you started.
4.
Enter the file name under which you want to save any changes to the file, and
click
OK
.
5.
Select the number of video boards, audio boards, and matrix model for which
you are preparing a configuration, and click
OK
.
6.
Continue using the program as described on page 5-3.
Using the help system
For information about program features, you can access the help program in any of
the following ways:
• From the Extron Electronics program folder or group, double-
click on the MATRIX S Help icon (shown at right).
• From within the Matrix Switcher Control Program, click on the
Help
menu on the main screen.
• From within the Matrix Switcher Control Program, press the F1 key.
Optimizing the Video
Most MTP transmitters and the first 25% of the MTPX TP outputs have a pre-
peaking feature.
Set these features as follows for the best image quality:
1
.
For inputs from MTP T 15HD products
only
—
If the cable between the
MTP transmitter and the MTPX Plus is > 300', turn the transmitter’s Pre-Peak
switch on. For shorter cables, turn the switch off.
2
.
For outputs —
If the cable between the MTPX and the receiver is > 300', turn
the MTPX’s Pre-Peak feature on. For shorter cables, turn the feature off.
N
MTPX Pre-Peak is available on the first 25% of the MTPX Plus outputs (for
example outputs 1 through 4 for an MTPX Plus 168.
N
See the MTPX configurations settings menu item in “Tools menu”, on
page 5-11.
This setting can also be made using SIS command. See chapter 4,
“Programmer’s Guide”.
N
Unless the TP cable lengths are changed, these settings should need to be made
only once, during installation.
3
.
If level/peaking and skew adjustments are available on the connected
receiver(s), set them in accordance with the applicable MTP product manual.
Summary of Contents for MTPX 1616
Page 1: ...MTPX Series Mini Twisted Pair Matrix Switcher 68 1285 01 Rev C 04 09 ...
Page 4: ......
Page 26: ...Installation cont d MTPX Twisted Pair Matrix Switchers Installation 2 10 PRELIMINARY ...
Page 76: ...Operation cont d MTPX Twisted Pair Matrix Switchers Operation 3 50 PRELIMINARY ...
Page 78: ...Operation cont d MTPX Twisted Pair Matrix Switchers Operation 3 52 PRELIMINARY ...
Page 80: ...Operation cont d MTPX Twisted Pair Matrix Switchers Operation 3 54 PRELIMINARY ...