background image

MTP U T A D • Installation and Operation

 

2-13

Receiver Considerations

N

 

The video format selected in the transmitter requires a 

compatible receiver.  A universal receiver, such as the 

MTP U R RSA SEQ, is recommended.

N

 

Up to seven receivers (MTP RL 15HD A, with or 

without SEQ) can be connected in series.  This daisy 

chain is accomplished using the standard receivers' 

Buffered Output connectors.  The total distance from the 

transmitter’s TP output to the last receiver in the chain 

should not exceed the recommended distance for the 

resolution being used.

N

 

The receivers' buffered outputs do not provide 

pre-peaking control.  The total recommended distance 

for an entire daisy chain is the same as for a single 

transmitter and receiver.  The transmitter's Pre-Peak 

switch has the same effect on the recommended 

transmission distance for a daisy chain as for a single 

transmitter and receiver.

N

 

See the recommended transmission ranges in the table 

on page 1-4.  The recommendations in the table apply 

equally for a single transmitter and receiver and for a 

transmission daisy chain.  For example, the maximum 

suggested range for 1024 x 768 video is 300 feet with 

Pre-Peak off and 500 feet with Pre-Peak on for either one 

transmitter and one receiver or one transmitter and three 

daisy-chained receivers.

N

 

For daisy-chained units, the first receiver in the chain 

must be at least 100 feet from the transmitter when the 

Pre-Peak switch is on.

N

 

For daisy-chained units, any receiver in the chain closer 

than 350 feet may experience some form of over-peaking 

when the Pre-Peak switch is on.

Summary of Contents for MTP U T A D

Page 1: ...urope Only 31 33 453 4040 31 33 453 4050 FAX Extron Asia 800 7339 8766 Inside Asia Only 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511 7656 FAX Extron China 400 883 1568 Inside Ch...

Page 2: ...n sollten Sie alle Netzkabel aus der R ckseite des Ger tes aus der externen Stomversorgung falls dies m glich ist oder aus der Wandsteckdose ziehen Schutz des Netzkabels Netzkabel sollten stets so ver...

Page 3: ...ection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in acc...

Page 4: ...e wall box 2 2 Final installation 2 5 Connections and Settings 2 6 Front panel features 2 6 Video connections 2 6 Audio connections 2 7 Configuration switches 2 8 Status LEDs 2 9 Rear panel features 2...

Page 5: ...nts Table of Contents cont d MTP U T A D 1 Chapter One Introduction About the Universal MTP Decora Transmitter Twisted Pair TP Cable Advantages All trademarks mentioned in this manual are the properti...

Page 6: ...g Decora form factor that is fully compatible with all MTP video and audio receivers and associated MTP products The MTPs transmit and receive over Extron Enhanced Skew Free A V UTP cable or over CAT...

Page 7: ...m 350 105 m 500 150 m 600 185 m 1280 x 960 300 90 m 350 105 m 400 120 m 500 150 m 1280 x 1024 250 75 m 300 90 m 350 105 m 450 135 m Video format Pre Peak off Pre Peak on Max distance high quality Max...

Page 8: ...cables into the wall furniture or conduits before installing the wall plate N The Decora unit is 1 5 16 inch 33 m deep and has connectors on the back side figure 2 1 on page 2 3 Extron recommends its...

Page 9: ...insulate exposed cable shields with heat shrink to reduce the chance of short circuits To prevent short circuits the outer foil shield can be cut back to the point where the cable exits the cable clam...

Page 10: ...t connector a only c YUV component video input connectors Connect a component video source to these RCA jacks for a high or low resolution component video input d S video input connector Connect an S...

Page 11: ...d resolutions By default the vertical refresh rate for all resolutions is 60 Hz The resolution can be set to 50 Hz using the Refresh DIP switch h Pos Pos Pos Source or Resolution Resolution Resolution...

Page 12: ...re installing them in the direct insertion connector Tinned wires are not as secure in the connectors and could be pulled out Use the supplied tie wrap to strap the power cord to the extended tail of...

Page 13: ...n Side Green Blue Blue Reserved Composite Reserved Video Reserved Reserved Component Video R Y R Y Y B Y B Y Y Stereo audio Reserved Reserved Chroma C Chroma C Luma Y Luma Y S video 12345678 RJ 45 Con...

Page 14: ...as for a single transmitter and receiver The transmitter s Pre Peak switch has the same effect on the recommended transmission distance for a daisy chain as for a single transmitter and receiver N See...

Page 15: ...ipment or identified by viewing a crosshatch test pattern with a critical eye to determine if either the red green or blue video image leads appears to the left of the other two video images Try using...

Page 16: ...C of S video Minimum maximum levels 0 3 V to 1 45 Vp p Impedance 75 ohms Horizontal frequency 15 kHz to 130 kHz Vertical frequency 30 Hz to 150 Hz Return loss 30 dB 5 MHz DC offset max allowable 250 m...

Page 17: ...iation Regulatory compliance Safety CE c UL UL EMI EMC CE C tick FCC Class A ICES VCCI MTBF 30 000 hours Warranty 3 years parts and labor N All nominal levels are at 10 N Specifications are subject to...

Page 18: ...ty 10 100 476 01 CAT 6 jack red qty 10 100 477 01 CAT 6 jack blue qty 10 100 478 01 CAT 6 jack orange qty 10 100 479 01 CAT 6 jack gray qty 10 100 480 01 CAT 6 jack white qty 10 100 481 01 CAT 6 jack...

Page 19: ...MTP U T A D Reference Information Reference Information cont d A 8...

Reviews: