ATTENTION:

 

• 

 The DC output cables must be kept separate from each other while the power 
supply is plugged in. Remove power before wiring

• 

Les câbles de sortie CC doivent être séparés les uns des autres tant que la 
source d’alimentation est branchée. Coupez l’alimentation avant d’effectuer les 
raccordements.

• 

Do not

 connect power to the amplifier until you have read the ATTENTION 

notifications.

• 

Ne branchez pas l’alimentation au l’amplificateur

 

avant d’avoir lu les mises en garde 

« ATTENTION ».

• 

Always use a power supply supplied or specified by Extron. Use of an unauthorized 
power supply voids all regulatory compliance certification and may cause damage 
to the supply and the end product.

• 

Utilisez toujours une source d’alimentation fournie ou recommandée par Extron. 
L’utilisation d’une source d’alimentation non autorisée annule toute certification de 
conformité réglementaire et peut endommager la source d’alimentation et l’unité.

• 

If not provided with a power supply, this product is intended to be supplied by a 
power source marked “Class 2” or “LPS” and rated at 12 VDC and a minimum of 
0.5 A.

• 

Si le produit n’est pas fourni avec une source d’alimentation, il doit être alimenté par 
une source d’alimentation de classe 2 ou LPS, avec une tension nominale 12 Vcc, 
0,5 A minimum.

• 

The installation must always be in accordance with the applicable provisions of 
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical 
Code part 1, section 16. The power supply shall not be permanently fixed to 
building structure or similar structure.

• 

Cette installation doit toujours être conforme aux dispositions applicables du Code 
américain de l’électricité (National Electrical Code) ANSI/NFPA 70, article 725, et 
du Code canadien de l’électricité, partie 1, section 16. La source d’alimentation ne 
devra pas être fixée de façon permanente à une structure de bâtiment ou à une 
structure similaire.

• 

Power supply voltage polarity is critical. Incorrect voltage polarity can damage the 
power supply and the unit. The ridges on the side of the cord (see 

figure 2

 on the 

previous page) identify the power cord negative lead.

• 

La polarité de la source d’alimentation est primordiale. Une polarité incorrecte 
pourrait endommager la source d’alimentation et l’unité. Les stries sur le côté 
du cordon (voir 

figure 2

) permettent de repérer le pôle négatif du cordon 

d’alimentation.

• 

To verify the polarity before connection, plug in the power supply with no load and 
check the output with a voltmeter.

• 

Pour vérifier la polarité avant la connexion, brancher l’alimentation hors charge et 
mesurer sa sortie avec un voltmètre.

Summary of Contents for MP 101

Page 1: ...User Guide MP 101 Series Category Microphone to Line Preamplifiers 68 992 02 Rev B 04 19...

Page 2: ...dad de Extron referencia 68 290 01 en el sitio Web de Extron www extron com Instructions de s curit Fran ais AVERTISSEMENT Ce pictogramme lorsqu il est utilis sur le produit signale l utilisateur la p...

Page 3: ...IP Intercom IP Link Key Minder LinkLicense LockIt MediaLink MediaPort NetPA PlenumVault PoleVault PowerCage PURE3 Quantum Show Me SoundField SpeedMount SpeedSwitch StudioStation System INTEGRATOR Tea...

Page 4: ...at the expense of the user NOTES if only this paragraph is used reformat to single NOTE format For more information on safety guidelines regulatory compliances EMI EMF compatibility accessibility and...

Page 5: ...or Wiring 7 Remote Control Options 7 MP 101 AAP 8 Front Panel Features 8 Adjusting the MP 101 AAP 9 Mounting the MP 101 AAP 9 Remote Control 10 Remote Connector Wiring 10 Remote Control Options 11 MP...

Page 6: ...Technical Publications Standards and Styles Contents vi...

Page 7: ...m power and low cut filtering Remote control is available through optional Extron VCM 110 AAP panel which control volume and muting Features Compact size The MP 101 is housed in a 1U high 1 8 rack wid...

Page 8: ...wer MP 101 APP and MP 101 D 4 Mic Input Figure 1 MP 101 MP 101 APP and MP 101 D Rear Panel Power Connector 1 Power connector An external 12 V power supply is included with the unit Plug it into this 2...

Page 9: ...nt par une source d alimentation de classe 2 ou LPS avec une tension nominale 12 Vcc 0 5 A minimum The installation must always be in accordance with the applicable provisions of National Electrical C...

Page 10: ...t s murales Remote power is intended for indoors use only No part of a network that uses remote power can be routed outdoors L alimentation distance est exclusivement r serv e un usage en int rieur Un...

Page 11: ...Screw Connector stripping 3 16 Tip Sleeve Ring Balanced Output Figure 4 Audio Wiring Output ATTENTION For unbalanced audio connect the sleeve s to the ground DO NOT connect the sleeves to the negative...

Page 12: ...the MP 101 in a rack UL Rack Mounting Guidelines 1 Elevated operating ambient temperature If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environmen...

Page 13: ...ometer clockwise towards the 75 dB mark to increase the volume but not past the point where distortion occurs Remote Control The wiring and control options described below pertain to all models in the...

Page 14: ...ee the image on the right for connector pin out information 2 Mic Gain A recessed adjustable potentiometer defines the amount of input signal between 25 and 72 dB allowed into the preamp This potentio...

Page 15: ...there is a remote control connection unplug it while adjusting the Mic Gain potentiometer Replace the remote control when finished 4 If there is minimal distortion but greater volume is required turn...

Page 16: ...age for detailed instructions 6 Pretest the MP 101 AAP before final mounting of the faceplate 7 Perform the final mount by attaching the cabled device faceplate or AAP wallplate into a wall or piece o...

Page 17: ...e controller MLC 55 RS VC and MLC 64 RS VC D and VC 50 volume controller use a 10 k ohm potentiometer as the main method for controlling volume levels The VCM 110 AAP mute button overrides the mute bu...

Page 18: ...avoid tampering To adjust the potentiometer use a small screwdriver to remove the covering make adjustments then replace the cap 4 XLR mic input An XLR connector for a standard microphone connection...

Page 19: ...D into a Decorator style faceplate do the following 1 Secure all cables and connections onto the MP 101 D 2 If it was not done previously adjust the MP 101 D from its rear panel see Adjusting the MP 1...

Page 20: ...MP 101 D has three remote control options 1 The Extron VCM 110 AAP volume mute controller VCM 200 Series volume mute controller VC 50 volume controller MLC 55 RS VC and MLC 64 RS VC D and VC 50 volume...

Page 21: ...t d installer le bo tier Preparing the Site and Installing the Wall Box Choose a location that allows cable runs without interference Allow enough depth for both the wall box and the cables You may ne...

Page 22: ...he edges of the opening if needed 5 Feed cables through the wall box punch out holes and secure them with cable clamps to provide strain relief 6 Exposed cable shields braids or foil are potential sou...

Page 23: ...urniture surface See the illustration below which applies to one two three and four gang wall boxes Installation Cable Cable Clamp Wall Stud Installation Cable Cable Clamp Wall Stud Screws or Nails Sc...

Page 24: ...1 D 18 Dimensions and Template for the MP 101 D Dimensions NOTE Always check and use the dimensions in this appendix 0 33 8 4 mm 1 29 32 8 mm 0 17 4 3 mm 4 10 104 mm 2 6 66 mm 0 33 8 4 mm 0 13 3 3 mm...

Page 25: ...s template is not to scale 4 50 114 3 mm Cut Out Line for Installing the Electrical Box Top Panel 2 79 70 9 mm MP 101 D Cut Out Template for the Extron 2 24 105 cm 4 13 57 cm SURFACE CUT OUT AREA FOR...

Page 26: ...Dubai Airport Free Zone F13 PO Box 293666 United Arab Emirates Dubai This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse...

Reviews: