background image

MP 101 Series • Introduction

1

Introduction

About this Manual

This manual contains information about the MP 101, the MP 101 AAP, and the MP 101 D 
microphone to line preamplifiers and provides instructions on how to mount and operate 
these units.

About the MP 101, MP 101 AAP, and MP 101 D

The Extron MP 101, MP 101 AAP, and MP 101 D (the MP 101 Series) are high quality 
microphone to line level audio preamplifiers. These products can add microphone capability 
to most Extron audio and switcher systems.
The MP 101 is rack-mountable, while the MP 101 AAP is an AAP plate option for easy 
integration into Extron architectural products. The MP 101 D works similarly to the other two 
units, but features a Decorator-style wallplate mounting option. Information on its installation 
and operation are found in 

MP 101 D

 starting on page 12.

Each model features a recessed Mic Gain potentiometer that provides a 25 to 72 dB 
adjustment range, compensating for different microphone sensitivities. Each model also 
features an on/off switch for 48 volt phantom power and low cut filtering. Remote control is 
available through optional Extron VCM 110 AAP panel, which control volume and muting.

Features

• 

Compact size

 — The MP 101 is housed in a 1U high, 1/8 rack width, 3” deep, metal 

enclosure, the MP 101 AAP is housed in a two-space AAP plate; and the MP 101 D is 
mounted into a wallplate. These three options allow for diverse applications.

• 

Quick plug input and outputs

 — Connectors are captive screw or XLR (MP 101 AAP 

and MP 101 D only) for quick installation.

• 

Gain control

 — Provides a wide gain adjustment range of 25 to 72 dB.

• 

Switchable low cut filter

 — Provides low cut filter to remove wind and “table rumble” 

noise.

• 

Switchable phantom power

 — Provides 48 volt phantom power for condenser 

microphones.

• 

Volume and mute remote control

 — Each model can be remotely controlled for 

volume adjustment and muting via a rear panel Remote connector.

• 

Flexible mounting options

 — The MP 101 can be mounted on a rack, on a table, or 

under furniture. The MP 101 AAP mounts into various Extron architectural products. 
The MP 101 D is wall mountable using standard, off-the-shelf mounting accessories.

• 

External international power supply

 — The autoswitchable, 12 VDC, 0.5 A external 

power supply provides worldwide power compatibility.

Summary of Contents for MP 101

Page 1: ...User Guide MP 101 Series Category Microphone to Line Preamplifiers 68 992 02 Rev B 04 19...

Page 2: ...dad de Extron referencia 68 290 01 en el sitio Web de Extron www extron com Instructions de s curit Fran ais AVERTISSEMENT Ce pictogramme lorsqu il est utilis sur le produit signale l utilisateur la p...

Page 3: ...IP Intercom IP Link Key Minder LinkLicense LockIt MediaLink MediaPort NetPA PlenumVault PoleVault PowerCage PURE3 Quantum Show Me SoundField SpeedMount SpeedSwitch StudioStation System INTEGRATOR Tea...

Page 4: ...at the expense of the user NOTES if only this paragraph is used reformat to single NOTE format For more information on safety guidelines regulatory compliances EMI EMF compatibility accessibility and...

Page 5: ...or Wiring 7 Remote Control Options 7 MP 101 AAP 8 Front Panel Features 8 Adjusting the MP 101 AAP 9 Mounting the MP 101 AAP 9 Remote Control 10 Remote Connector Wiring 10 Remote Control Options 11 MP...

Page 6: ...Technical Publications Standards and Styles Contents vi...

Page 7: ...m power and low cut filtering Remote control is available through optional Extron VCM 110 AAP panel which control volume and muting Features Compact size The MP 101 is housed in a 1U high 1 8 rack wid...

Page 8: ...wer MP 101 APP and MP 101 D 4 Mic Input Figure 1 MP 101 MP 101 APP and MP 101 D Rear Panel Power Connector 1 Power connector An external 12 V power supply is included with the unit Plug it into this 2...

Page 9: ...nt par une source d alimentation de classe 2 ou LPS avec une tension nominale 12 Vcc 0 5 A minimum The installation must always be in accordance with the applicable provisions of National Electrical C...

Page 10: ...t s murales Remote power is intended for indoors use only No part of a network that uses remote power can be routed outdoors L alimentation distance est exclusivement r serv e un usage en int rieur Un...

Page 11: ...Screw Connector stripping 3 16 Tip Sleeve Ring Balanced Output Figure 4 Audio Wiring Output ATTENTION For unbalanced audio connect the sleeve s to the ground DO NOT connect the sleeves to the negative...

Page 12: ...the MP 101 in a rack UL Rack Mounting Guidelines 1 Elevated operating ambient temperature If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environmen...

Page 13: ...ometer clockwise towards the 75 dB mark to increase the volume but not past the point where distortion occurs Remote Control The wiring and control options described below pertain to all models in the...

Page 14: ...ee the image on the right for connector pin out information 2 Mic Gain A recessed adjustable potentiometer defines the amount of input signal between 25 and 72 dB allowed into the preamp This potentio...

Page 15: ...there is a remote control connection unplug it while adjusting the Mic Gain potentiometer Replace the remote control when finished 4 If there is minimal distortion but greater volume is required turn...

Page 16: ...age for detailed instructions 6 Pretest the MP 101 AAP before final mounting of the faceplate 7 Perform the final mount by attaching the cabled device faceplate or AAP wallplate into a wall or piece o...

Page 17: ...e controller MLC 55 RS VC and MLC 64 RS VC D and VC 50 volume controller use a 10 k ohm potentiometer as the main method for controlling volume levels The VCM 110 AAP mute button overrides the mute bu...

Page 18: ...avoid tampering To adjust the potentiometer use a small screwdriver to remove the covering make adjustments then replace the cap 4 XLR mic input An XLR connector for a standard microphone connection...

Page 19: ...D into a Decorator style faceplate do the following 1 Secure all cables and connections onto the MP 101 D 2 If it was not done previously adjust the MP 101 D from its rear panel see Adjusting the MP 1...

Page 20: ...MP 101 D has three remote control options 1 The Extron VCM 110 AAP volume mute controller VCM 200 Series volume mute controller VC 50 volume controller MLC 55 RS VC and MLC 64 RS VC D and VC 50 volume...

Page 21: ...t d installer le bo tier Preparing the Site and Installing the Wall Box Choose a location that allows cable runs without interference Allow enough depth for both the wall box and the cables You may ne...

Page 22: ...he edges of the opening if needed 5 Feed cables through the wall box punch out holes and secure them with cable clamps to provide strain relief 6 Exposed cable shields braids or foil are potential sou...

Page 23: ...urniture surface See the illustration below which applies to one two three and four gang wall boxes Installation Cable Cable Clamp Wall Stud Installation Cable Cable Clamp Wall Stud Screws or Nails Sc...

Page 24: ...1 D 18 Dimensions and Template for the MP 101 D Dimensions NOTE Always check and use the dimensions in this appendix 0 33 8 4 mm 1 29 32 8 mm 0 17 4 3 mm 4 10 104 mm 2 6 66 mm 0 33 8 4 mm 0 13 3 3 mm...

Page 25: ...s template is not to scale 4 50 114 3 mm Cut Out Line for Installing the Electrical Box Top Panel 2 79 70 9 mm MP 101 D Cut Out Template for the Extron 2 24 105 cm 4 13 57 cm SURFACE CUT OUT AREA FOR...

Page 26: ...Dubai Airport Free Zone F13 PO Box 293666 United Arab Emirates Dubai This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse...

Reviews: