background image

Precautions

This symbol is intended to alert the user of important
operating and maintenance (servicing) instructions
in the literature provided with the equipment.

This symbol is intended to alert the user of the
presence of uninsulated dangerous voltage within
the product's enclosure that may present a risk of
electric shock.

Caution

Read

 Instructions • Read and understand all safety and operating

instructions before using the equipment.

Retain Instructions • 

The safety instructions should be kept for future

reference.

Follow Warnings • 

Follow all warnings and instructions marked on the

equipment or in the user information.

Avoid Attachments • 

Do not use tools or attachments that are not

recommended by the equipment manufacturer because they may be
hazardous.

Warning

Power sources • 

This equipment should be operated only from the power source

indicated on the product. This equipment is intended to be used with a main
power system with a grounded (neutral) conductor. The third (grounding) pin is
a safety feature, do not attempt to bypass or disable it.

Power disconnection • 

To remove power from the equipment safely, remove all

power cords from the rear of the equipment, or the desktop power module (if
detachable), or from the power source receptacle (wall plug).

Power cord protection • 

Power cords should be routed so that they are not likely to

be stepped on or pinched by items placed upon or against them.

Servicing • 

Refer all servicing to qualified service personnel. There are no user-

serviceable parts inside. To prevent the risk of shock, do not attempt to service
this equipment yourself because opening or removing covers may expose you to
dangerous voltage or other hazards.

Slots and openings • 

If the equipment has slots or holes in the enclosure, these are

provided to prevent overheating of sensitive components inside. These openings
must never be blocked by other objects.

Lithium battery • 

There is a danger of explosion if battery is incorrectly replaced.

Replace it only with the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the manufacturer's
instructions.

Ce symbole sert à avertir l’utilisateur que la
documentation fournie avec le matériel contient des
instructions importantes concernant l’exploitation
et la maintenance (réparation).

Ce symbole sert à avertir l’utilisateur de la présence
dans le boîtier de l’appareil de   tensions dangereuses
non isolées posant des risques d’électrocution.

Attention

Lire les instructions• 

Prendre connaissance de toutes les consignes de

sécurité et d’exploitation avant d’utiliser le matériel.

Conserver les instructions• 

Ranger les consignes de sécurité afin de

pouvoir les consulter à l’avenir.

Respecter les avertissements • 

Observer tous les avertissements et

consignes marqués sur le matériel ou présentés dans la documentation
utilisateur.

Eviter les pièces de fixation • 

Ne pas utiliser de pièces de fixation ni

d’outils non recommandés par le fabricant du matériel car cela
risquerait de poser certains dangers.

Avertissement

Alimentations• 

Ne faire fonctionner ce matériel qu’avec la source d’alimentation

indiquée sur l’appareil. Ce matériel doit être utilisé avec une alimentation
principale comportant un fil de terre (neutre). Le troisième contact (de mise à la
terre) constitue un dispositif de sécurité : n’essayez pas de la contourner ni de la
désactiver.

Déconnexion de l’alimentation• 

Pour mettre le matériel hors tension sans danger,

déconnectez tous les cordons d’alimentation de l’arrière de l’appareil ou du
module d’alimentation de bureau (s’il est amovible) ou encore de la prise secteur.

Protection du cordon d’alimentation • 

Acheminer les cordons d’alimentation de

manière à ce que personne ne risque de marcher dessus et à ce qu’ils ne soient
pas écrasés ou pincés par des objets.

Réparation-maintenance • 

Faire exécuter toutes les interventions de réparation-

maintenance par un technicien qualifié. Aucun des éléments internes ne peut être
réparé par l’utilisateur. Afin d’éviter tout danger d’électrocution, l’utilisateur ne
doit pas essayer de procéder lui-même à ces opérations car l’ouverture ou le
retrait des couvercles risquent de l’exposer à de hautes tensions et autres dangers.

Fentes et orifices • 

Si le boîtier de l’appareil comporte des fentes ou des orifices,

ceux-ci servent à empêcher les composants internes sensibles de surchauffer. Ces
ouvertures ne doivent jamais être bloquées par des objets.

Lithium Batterie • 

Il a danger d'explosion s'll y a remplacment incorrect de la

batterie. Remplacer uniquement avec une batterie du meme type ou d'un ype
equivalent recommande par le constructeur. Mettre au reut les batteries usagees
conformement aux instructions du fabricant.

Safety Instructions • English

Consignes de Sécurité • Français

Sicherheitsanleitungen • Deutsch

Dieses Symbol soll dem Benutzer in der im
Lieferumfang enthaltenen Dokumentation
besonders wichtige Hinweise zur Bedienung und
Wartung (Instandhaltung) geben.

Dieses Symbol soll den Benutzer darauf aufmerksam
machen, daß im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen, die nicht isoliert
sind und die einen elektrischen Schock verursachen
können, herrschen.

Achtung

Lesen der Anleitungen 

• Bevor Sie das Gerät zum ersten Mal verwenden,

sollten Sie alle Sicherheits-und Bedienungsanleitungen genau
durchlesen und verstehen.

Aufbewahren der Anleitungen 

• Die Hinweise zur elektrischen Sicherheit

des Produktes sollten Sie aufbewahren, damit Sie im Bedarfsfall darauf
zurückgreifen können.

Befolgen der Warnhinweise 

• Befolgen Sie alle Warnhinweise und

Anleitungen auf dem Gerät oder in der Benutzerdokumentation.

Keine Zusatzgeräte 

• Verwenden Sie keine Werkzeuge oder Zusatzgeräte,

die nicht ausdrücklich vom Hersteller empfohlen wurden, da diese eine
Gefahrenquelle darstellen können.

Vorsicht

Stromquellen

 • Dieses Gerät sollte nur über die auf dem Produkt angegebene

Stromquelle betrieben werden. Dieses Gerät wurde für eine Verwendung mit
einer Hauptstromleitung mit einem geerdeten (neutralen) Leiter konzipiert. Der
dritte Kontakt ist für einen Erdanschluß, und stellt eine Sicherheitsfunktion dar.
Diese sollte nicht umgangen oder außer Betrieb gesetzt werden.

Stromunterbrechung 

• Um das Gerät auf sichere Weise vom Netz zu trennen,

sollten Sie alle Netzkabel aus der Rückseite des Gerätes, aus der externen
Stomversorgung (falls dies möglich ist) oder aus der Wandsteckdose ziehen.

Schutz des Netzkabels 

• Netzkabel sollten stets so verlegt werden, daß sie nicht

im Weg liegen und niemand darauf treten kann oder Objekte darauf- oder
unmittelbar dagegengestellt werden können.

Wartung 

• Alle Wartungsmaßnahmen sollten nur von qualifiziertem

Servicepersonal durchgeführt werden. Die internen Komponenten des Gerätes
sind wartungsfrei. Zur Vermeidung eines elektrischen Schocks versuchen Sie in
keinem Fall, dieses Gerät selbst öffnen, da beim Entfernen der Abdeckungen die
Gefahr eines elektrischen Schlags und/oder andere Gefahren bestehen.

Schlitze und Öffnungen 

• Wenn das Gerät Schlitze oder Löcher im Gehäuse

aufweist, dienen diese zur Vermeidung einer Überhitzung der empfindlichen
Teile im Inneren. Diese Öffnungen dürfen niemals von anderen Objekten
blockiert werden.

Litium-Batterie 

• Explosionsgefahr, falls die Batterie nicht richtig ersetzt wird.

Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen
vergleichbaren Batterietyp, der auch vom Hersteller empfohlen wird. Entsorgen
Sie verbrauchte Batterien bitte gemäß den Herstelleranweisungen.

Este símbolo se utiliza para advertir al usuario sobre
instrucciones importantes de operación y
mantenimiento (o cambio de partes) que se desean
destacar en el contenido de la documentación
suministrada con los equipos.

Este símbolo se utiliza para advertir al usuario sobre
la presencia de elementos con voltaje peligroso sin
protección aislante, que puedan encontrarse dentro
de la caja o alojamiento del producto, y que puedan
representar riesgo de electrocución.

Precaucion

Leer las instrucciones • 

Leer y analizar todas las instrucciones de

operación y seguridad, antes de usar el equipo.

Conservar las instrucciones • 

Conservar las instrucciones de seguridad

para futura consulta.

Obedecer las advertencias • 

Todas las advertencias e instrucciones

marcadas en el equipo o en la documentación del usuario, deben ser
obedecidas.

Evitar el uso de accesorios • 

No usar herramientas o accesorios que no

sean especificamente recomendados por el fabricante, ya que podrian
implicar riesgos.

Advertencia

Alimentación eléctrica • 

Este equipo debe conectarse únicamente a la fuente/tipo

de alimentación eléctrica indicada en el mismo. La alimentación eléctrica de este
equipo debe provenir de un sistema de distribución general con conductor
neutro a tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no
puentearia ni eliminaria.

Desconexión de alimentación eléctrica • 

Para desconectar con seguridad la

acometida de alimentación eléctrica al equipo, desenchufar todos los cables de
alimentación en el panel trasero del equipo, o desenchufar el módulo de
alimentación (si fuera independiente), o desenchufar el cable del receptáculo de
la pared.

Protección del cables de alimentación • 

Los cables de alimentación eléctrica se

deben instalar en lugares donde no sean pisados ni apretados por objetos que se
puedan apoyar sobre ellos.

Reparaciones/mantenimiento • 

Solicitar siempre los servicios técnicos de personal

calificado. En el interior no hay partes a las que el usuario deba acceder. Para
evitar riesgo de electrocución, no intentar personalmente la reparación/
mantenimiento de este equipo, ya que al abrir o extraer las tapas puede quedar
expuesto a voltajes peligrosos u otros riesgos.

Ranuras y aberturas • 

Si el equipo posee ranuras o orificios en su caja/alojamiento,

es para evitar el sobrecalientamiento de componentes internos sensibles. Estas
aberturas nunca se deben obstruir con otros objetos.

Batería de litio • 

Existe riesgo de explosión si esta batería se coloca en la posición

incorrecta. Cambiar esta batería únicamente con el mismo tipo (o su equivalente)
recomendado por el fabricante. Desachar las baterías usadas siguiendo las
instrucciones del fabricante.

Instrucciones de seguridad • Español

FCC Class A Notice

Note:  This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules.  These limits are designed
to provide reasonable protection against harmful interference when the equipment is
operated in a commercial  environment.  This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the interference at his
own expense.

Note:  This unit was tested with shielded cables on the peripheral devices.  Shielded
cables must be used with the unit to ensure compliance.

Extron’s Warranty

Extron Electronics warrants this product against defects in materials and
workmanship for a period of three years from the date of purchase.  In the event of
malfunction during the warranty period attributable directly to faulty workmanship
and/or materials, Extron Electronics will, at its option, repair or replace said products
or components, to whatever extent it shall deem necessary to restore said product to
proper operating condition, provided that it is returned within the warranty period,
with proof of purchase and description of malfunction to:

USA, Canada, South America,

Europe, Africa, and the Middle East:

and Central America:

Extron Electronics, Europe

Extron Electronics

Beeldschermweg 6C

1230 South Lewis Street

3821 AH Amersfoort

Anaheim, CA 92805, USA

The Netherlands

Asia:

Japan:
Extron Electronics, Japan

Extron Electronics, Asia

Daisan DMJ Bldg. 6F,

135 Joo Seng Road, #04-01

3-9-1 Kudan Minami

PM Industrial Bldg.

Chiyoda-ku, Tokyo 102-0074

Singapore 368363

Japan

This Limited Warranty does not apply if the fault has been caused by misuse,
improper handling care, electrical or mechanical abuse, abnormal operating conditions
or non-Extron authorized modification to the product.

If it has been determined that the product is defective, please call Extron and ask for
an Applications Engineer at (714) 491-1500  (USA), 31.33.453.4040 (Europe),
65.6383.4400 (Asia), or 81.3.3511.7655 (Japan) to receive an RA# (Return Authorization
number).  This will begin the repair process as quickly as possible.

Units must be returned insured, with shipping charges prepaid.  If not insured, you
assume the risk of loss or damage during shipment.  Returned units must include the
serial number and a description of the problem, as well as the name of the person to
contact in case there are any questions.

Extron Electronics makes no further warranties either expressed or implied with
respect to the product and its quality, performance, merchantability, or fitness for any
particular use.  In no event will Extron Electronics be liable for direct, indirect, or
consequential damages resulting from any defect in this product even if Extron
Electronics has been advised of such damage.

Please note that laws vary from state to state and country to country, and that some
provisions of this warranty may not apply to you.

im Vertrieb von

            CAMBOARD Electronics

www.camboard.de

Tel. 07131 911201
Fax 07131 911203

[email protected]

Summary of Contents for IPL M PDP-ES

Page 1: ...ng Road 04 01 PM Industrial Building Singapore 368363 65 6383 4400 Fax 65 6383 4664 Extron Electronics Japan Daisan DMJ Building 6F 3 9 1 Kudan Minami Chiyoda ku Tokyo 102 0074 Japan 81 3 3511 7655 Fax 81 3 3511 7656 www extron com 2004 Extron Electronics All rights reserved User s Manual IP Link Tools 68 1021 01 Rev A 11 04 IPL M PDP ES im Vertrieb von CAMBOARD Electronics www camboard de Tel 071...

Page 2: ...nur von qualifiziertem Servicepersonal durchgeführt werden Die internen Komponenten des Gerätes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall dieses Gerät selbst öffnen da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und oder andere Gefahren bestehen Schlitze und Öffnungen Wenn das Gerät Schlitze oder Löcher im Gehäuse aufweist die...

Page 3: ...information Step 4 Affix the Extron IPL M PDP ES sticker label to the display covering the existing Pioneer label Step 5 Attach the network LAN cable to the LAN port of the IPL M PDP ES interface card installed in the Pioneer plasma Attach the other end to a switch hub router or a host PC as shown below See Ethernet LAN port in chapter 3 for more information on this connection IPL M PDP ES ACT LIN...

Page 4: ...guring the IPL M PDP ES using direct PC connection 3 6 Configuring the IPL M PDP ES using the RS 232 port 3 7 Firmware upgrades 3 8 Chapter 4 Communication and Control 4 1 Communication with the Interface Card 4 2 Accessing and using the Web server 4 2 Navigating the default Web pages 4 2 Status tab 4 2 Configuration tab 4 3 File Management tab 4 10 Pioneer tab 4 12 Table of Contents QS 2 Step 6 A...

Page 5: ... 4 21 Error responses 4 21 References to errors 4 22 Command response table for Simple Instruction Set SIS commands 4 23 Pioneer Plasma A V Device Control 4 29 Custom Web pages 4 29 Telnet port 23 4 29 Accessing and using Telnet 4 29 Direct port access port 2001 4 30 Using direct access 4 30 Port redirect 4 31 Troubleshooting 4 31 Power connections 4 31 Data connections 4 31 Serial connections 4 3...

Page 6: ...lay Compatible Pioneer plasma displays include the following models PDP 504CMX PDP 504CMX S PDP 434CMX PDP 50MXE1 PDP 50MXE1 S PDP 43MXE1 PDP 43MXE1 S About the IPL M PDP ES Interface Card The Extron IPL M PDP ES is an Ethernet based interface card designed to enhance the support and control of Pioneer s fourth generation plasma displays The IPL M PDP ES is powered directly from the plasma and inc...

Page 7: ... 2 Chapter Two Installation and Operation Installation Overview Installation of the IPL M PDP ES Interface Card Panel Features and Cabling Operation 1 4 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de ...

Page 8: ...ps Turn all of the equipment off Make sure that the Pioneer plasma is turned off and disconnected from its power source Remove the Pioneer communication ES card from the plasma Install the Extron IPL M PDP ES interface card Attach the LAN and serial cables to the Extron interface card See Connecting the Hardware in chapter 3 Turn on the devices in the following order serial controller or computer ...

Page 9: ...hite brown 7 White brown 8 Brown 8 Brown Crossover cable Side 1 Side 2 Pin Wire color Pin Wire color 1 White orange 1 White green 2 Orange 2 Green 3 White green 3 White orange 4 Blue 4 Blue 5 White blue 5 White blue 6 Green 6 Orange 7 White brown 7 White brown 8 Brown 8 Brown Figure 2 7 RJ 45 connector wiring For best performance use a shielded Ethernet cable Power 4 On Off indicator LED The green...

Page 10: ...ntered in the 2 second time frame the COM port remains or returns to being a control port only A mode 2 reset disconnects a pass through connection Mode 3 Holding the reset button until the Power LED blinks once 3 seconds followed by a momentary 1 second press turns events either On or Off depending on the current state of the events If the events are currently stopped following the momentary 1 se...

Page 11: ...is mode does the following 1 Enables ARP program capability 2 Sets the IP address back to its factory IP address 3 Sets the Subnet address back to its factory default 4 Sets the Gateway back to its factory default 5 Sets Port mapping back to its factory default 6 Turns DHCP off 7 Turns events off Nothing happens if the momentary press does not occur within one second Mode 5 Holding the reset butto...

Page 12: ...TCP IP protocol must be installed and properly configured To use the IPL M PDP ES on an existing Ethernet LAN intranet your network administrator can provide you with a unique IP address or confirm whether you need to set up the 3 2 Connecting the Hardware The IPL M PDP ES interface card is housed inside of an expansion slot namely the ES Card Slot of a fourth generation Pioneer plasma Figure 3 1 ...

Page 13: ...ou to configure the interface card Configuring the IPL M PDP ES using the ARP command You can make use of the ARP Address Resolution Protocol command to set up an IP address for your IPL M PDP ES The ARP command tells your computer to associate the interface card s MAC address with the assigned IP address You must then use ping to access the IPL M PDP ES unit at which point the device server s IP ...

Page 14: ...M PDP ES default Web page is displayed Refer to Communication with the Interface Card in chapter 4 for information on accessing the Web server 6 After verifying that the change was successful issue the arp d command at the DOS prompt For example arp d 10 13 170 15 removes 10 13 170 15 from the ARP table or arp d removes all static IP addresses from the ARP table Configuring the IPL M PDP ES using ...

Page 15: ...Control Troubleshooting 3 8 Firmware upgrades Firmware upgrades become available periodically as improvements are made to the versatility and functionality of the IPL M PDP ES interface card These upgrades are available for download from the Extron Web site For details on how to upgrade the firmware see Upgrading the firmware in chapter 4 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07...

Page 16: ...word protected see Passwords page later in this chapter If you are unable to access the Web server see Troubleshooting at the end of this chapter Navigating the default Web pages The IPL M PDP ES default Web pages include four tabs Status Configuration File Management and Pioneer for easy navigation of several administrative options including system status password control file management and cont...

Page 17: ... some of these fields follow Unit Name This name field can be changed to any valid name up to 12 alphanumeric characters The following characters are invalid in the unit name space and DHCP The Dynamic Host Configuration Protocol DHCP is an Internet protocol for automating the configuration of computers that use TCP IP DHCP can be used to automatically assign IP addresses deliver TCP IP stack conf...

Page 18: ...ice once in the Password field and then again in the Re enter Password field Characters in these fields are masked by asterisks The following characters are invalid in passwords space and As shown in figure 4 4 password protected connections allow two levels of protection administrator and user Administrators have access to status information and all function control Users have access to status in...

Page 19: ...ew email alerts within the Web server do the following 6 Obtain your gateway IP address from your system administrator 4 8 7 Click System Settings on the menu figure 4 2 on the left side of the window 8 Place the gateway IP address into the Gateway IP Address field 9 Click the Submit button Sending an email alert through Telnet To complete the process of sending an email alert you must send it thr...

Page 20: ...useful tool that allows you to use and upload existing and custom Web pages Custom pages can be developed using a third party Web page development program such as FrontPage or Dreamweaver File management also allows you to remove unnecessary or outdated files when they are no longer needed To add or update files 1 Select the File Management tab The File Management screen figure 4 8 is displayed Fi...

Page 21: ...default page of the Pioneer tab and allows users to view the description and current status of the Pioneer plasma Figure 4 9 Pioneer Display Status screen Display Controls page The Display Controls page figure 4 10 is accessible from the Controls link on the left side of the window According to password level the buttons and fields on this page allow you to control and or view the status of the Pi...

Page 22: ... display s multi screen function allows the simultaneous display of two inputs PIP allows a subscreen to display in one of the six areas of the main screen This function can be toggled off or on See the Pioneer Operating Instructions for additional information Advanced Controls page The Advanced Controls page figure 4 11 is accessible from the Advanced link on the left side of the window Explanati...

Page 23: ...lendar options and schedule the time and date of the weekly event figure 4 13 Figure 4 13 Pioneer Schedule calendar 4 Click Save to submit the schedule For Users this is a view only function 4 16 Monitor page Using the Monitor page figure 4 13 you can monitor power levels internal temperature and usage of the Pioneer plasma An email notification can be sent to a recipient when specified conditions...

Page 24: ...All commands listed below will work using either connection method but due to some limitations of the Web browser the encapsulation characters are modified to make sure that the Web browser will properly handle them All examples in the command response table show the proper implementation in a Telnet or Web browser session Note for Web browsers all non alphanumeric characters must be represented a...

Page 25: ...s a valid command it executes the command and sends a response to the host device If the unit is unable to execute the command because the 4 21 X13 Set local date and time format MM DD YY HH MM SS e g 11 18 04 10 54 00 Read local date and time format day of week date month year HH MM SS e g Thu 18 Nov 2004 18 19 33 X14 IP address xxx xxx xxx xxx Leading zeros in each of four fields are optional in...

Page 26: ...A0 2A3DCE Cpn1 Cce400 200 0 3D View receive timeout Esc 1CE W1CE 00400 00200 0 00003D Set redirect mode 24 Esc 2 1 500 3DCD W2 2A1 2A500 2A3DCP Cpn 2 Ccd 1 00500 00003D Terminated redirect mode 24 Esc 1 0CD W1 2A0CD Cpn 1 Ccd 00000 00000 00000L View redirect mode Esc 1CD W1CD 00002 00500 00003D Firmware Version Part Number Information Query firmware version Q Q X11 Query verbose version informatio...

Page 27: ...4 View gateway IP address 24 Esc CG WCG X14 Set verbose mode 24 Esc X22 CV W X22 CV Vrb X22 View verbose mode Esc CV WCV X22 Get connection listing Esc CC WCC Number of connections 4 24 Command ASCII Telnet URL Encoded Web Response Password and Security Settings Set administrator password 24 Esc X33 CA W X33 CA Ipa X41 Clear administrator password 24 Esc CA W 20CA Ipa View administrator password 2...

Page 28: ... WMT port Set Web port map 24 Esc port MH W port MH Pmh port Command ASCII Telnet URL Encoded Web Response Re map port designations continued Reset Web port map 24 Esc 80MH W80MH Pmh 00080 Disable Web port map 24 Esc 0MH W0MH Pmh 00000 View Web port map 24 Esc MH WMH port Set Direct Access port map 24 Esc port MD W port MD Pmd port Reset Direct Access port map 24 Esc 2001MD W 2001MD Pmd 02001 Disa...

Page 29: ... ways These include Web pages Telnet and direct port access Custom Web pages These pages can be either modified versions of the existing Web pages or new Web pages developed in the field Web page development can be done with a Web site development tool such as FrontPage or Dreamweaver Custom Web pages are loadable with the Web server File Manager see File Management tab earlier in this chapter If ...

Page 30: ...ection for detailed instructions You can force the direct access session to close by logging on as administrator and entering Esc 1 0CD Port redirect Using the port redirector the card allows data to be sent and received directly to and from the display and back to the client e g a PC or the MLC 206 without any processing 1 Open another Telnet session see the previous section for details 2 Reestab...

Page 31: ...card baud rate matches that of the control device e g a PC or the MLC 206 If status is missing or unavailable check the following 1 Ensure that the Pioneer plasma ID is set to 01 see the Pioneer plasma documentation for details 2 Check that the IPL M PDP ES interface card baud rate matches that of the control device e g a PC or the MLC 206 3 Ensure that the redirect port has been enabled If you ar...

Page 32: ...lex level autodetected IP address 192 168 254 254 subnet mask 255 255 0 0 default gateway 0 0 0 0 DHCP off Serial control interface Port number type 1 RS 232 Connectors 1 9 pin female D Baud rate and protocol 1200 2400 4800 9600 default 19200 38400 baud adjustable 8 data bits 1 stop bit no parity Pin configurations RS 232 2 RX 3 TX 5 GND General Power Supplied by a Pioneer plasma display Temperatu...

Page 33: ...ions Part Numbers and Accessories Specifications Part Numbers Accessories cont d IPL M PDP ES B Appendix B Glossary A 4 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de ...

Page 34: ...ests network connections It is used to determine if the host has an operating connection and is able to exchange information with another host B 2 GLOSSARY 10 100Base T is Ethernet that uses Unshielded Twisted Pair UTP Cat 5 etc cable in which the amount of data transmitted between two points in a given amount of time is equal to either 10 Mbps or 100 Mbps Address Resolution Protocol ARP is a prot...

Page 35: ... Protocol TCP IP is the communication protocol language of the Internet Computers and devices with direct access to the Internet are provided with a copy of the TCP IP program to allow them to send and receive information in an understandable form Telnet is a utility available on most PCs that allows the computer system to communicate with one of its remote users clients A user who wishes to acces...

Page 36: ...IPL M PDP ES Glossary Glossary cont d B 6 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de ...

Reviews: