Twisted Pair Recommendations for DTP, XTP, and HDBaseT Communication

Extron recommends using the following practices to achieve full transmission distances  
and reduce transmission errors:

• 

Use Extron XTP/DTP 24 SF/UTP cable for the best performance. At a minimum, Extron 
recommends 24 AWG, solid conductor, STP cable with a minimum bandwidth of 
400 MHz.

• 

Terminate cables with shielded connectors to the TIA/EIA-T568B standard (shown at 
right).

• 

Limit the use of more than two pass-through points, which may include patch points, 
punch down connectors, couplers, and power injectors. If these pass-through points 
are required, use shielded couplers and punch down connectors.

ATTENTION:

 

• 

Do not connect these connectors to a telecommunications or computer data 
network.

• 

Ne connectez pas ces ports à des données informatiques ou à un réseau de 
télécommunications ou de données informatiques.

• 

DTP remote power is intended for indoor use only. No part of the network that 
uses DTP remote power should be routed outdoors.

• 

L’alimentation DTP à distance est destiné à une utilisation en intérieur 
seulement. Aucune partie du réseau qui utilise l’alimentation DTP à distance ne 
peut être routée en extérieur.

NOTE:

  When using shielded twisted pair cable in bundles or conduits, consider the following:

• 

Do not exceed 40% fill capacity in conduits.

• 

Do not comb the cable for the first 20 meters, where cables are straightened, aligned, and secured in tight bundles.

• 

Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.

• 

Separate twisted pair cables from AC power cables.

Audio Wiring

Wire the audio input and output connectors as shown at right. Use 
the supplied tie wrap to strap the audio cable to the extended tail 
of the connector. This does not apply to the amplified audio output 
connector on the SA and MA models.

ATTENTION:

 

• 

For unbalanced outputs, do not connect wires to the 
“-” poles (see the illustration at right).

• 

Pour les sorties asymétriques, ne connectez pas de 
câbles aux pôles « - » (voir l’illustration

 

de droite).

NOTE:

  The length of exposed wires is critical. The ideal length 

is 3/16 inch (5 mm).

IR Over TP Wiring

To transmit and receive IR signals, connect a control device to the 
three-pole Over TP IR connector (G, Tx, and Rx). 

NOTE:

  RS-232 data can be inserted via Ethernet only (see the 

IN1806 and 

IN1808 Series User Guide

 for details).

TIA/EIA-T568B

Pin Wire Color

1

White-orange

2

Orange

3

White-green

4

Blue

5

White-blue

6

Green

7

White-brown

8

Brown

1 2 3 4 5 6 7 8

RJ-45

Connector

Insert Twisted

Pair Wires

Pins:

Balanced Audio Output

Tip

Ring

Tip

Ring

Sleeves

Unbalanced Audio Output

Tip

No Ground Here

No Ground Here

Tip

Sleeves

LR

LR

Unbalanced Audio Input

Balanced Audio Input

Tip

Ring

Tip

Ring

Sleeves

Tip

Sleeve

Sleeve

Tip

LR

LR

Do not tin the wires!

Audio Inputs and Outputs 1 – 4 and Aux

Mic/Line Inputs 1 and 2

Balanced Audio Input

Tip

Sleeve

Ring

Unbalanced Audio Input

Tip

Sleeve