Extron electronics EBP 108 RAAP Button Panel Setup Manual Download Page 7

7

Product Category

Step 5: Cable All Devices

Attach cables using the diagrams in this section as a guide. Connect a 4-pole captive screw connector to each end of the cable, 
wiring both ends as shown in figure 6. In most cases the EBPs are powered by the IPCP Pro control processor that provides the 
eBUS signal. Power is carried on the V+ pin of each eBUS connection.
The four connectors are:

• 

+V

 — carries 12 VDC power from the controller, active hub, or power supply

• 

+S

 — carries the positive data signal

• 

-S

 — carries the negative data signal

• 

 

G

 — ground

Extron STP20-2/1000 or STP20-2P/1000 cable is recommended for eBUS connections.

Ground

+

 Signal

+

12 VDC

-

 Signal

Drain Wires (2)

G

-S

+S

+V

Black

White

Green

Red

Figure 6. 

Basic eBUS Connector Wiring and Cable Color Code

NOTES:

• 

The four eBUS ports are interchangeable: any port can be used to connect the device to a controller or EBDB 
distribution hub and any port can be used to daisy-chain the device to another EBP.

• 

Connect up to eight eBUS devices for each IPCP Pro control processor.

• 

Wire the connectors in the same way at both ends.

• 

Do not exceed a total of 1000 feet (305 meters) of cable for connections between the IPCP Pro and all the EBP panels.

• 

Do NOT power an EBP from more than one power source. Power is provided by the IPCP Pro. If additional power is 
required, use a PS 1220EB power supply and distribution hub, or an Extron 12 VDC power supply. If more than one 
power source is used in a system, disconnect the +V pin appropriately to ensure that the devices powered by the first 
source are isolated from the devices powered by the second source by (see 

figure 7

 on the following page).

ATTENTION:

• 

Always use a power supply supplied or specified by Extron. Use of an unauthorized power supply voids all regulatory 
compliance certification and may cause damage to the supply and the unit. 

• 

Utilisez toujours une source d’alimentation fournie par Extron. L’utilisation d’une source d’alimentation non autorisée 
annule toute conformité réglementaire et peut endommager la source d’alimentation ainsi que l’unité.

• 

If not provided with a power supply, this product is intended to be supplied by a UL Listed power source marked 
“Class 2” or “LPS” and rated output 12 VDC, minimum 1.5 A.

• 

Si ce produit ne dispose pas de sa propre source d’alimentation électrique, il doit être alimenté par une source 
d’alimentation certifiée UL de classe 2 ou LPS et paramétré à 12 VDC et 1,5 A minimum.

• 

Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities.

• 

Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une utilisation dans les espaces d’aération 
ou dans les cavités murales.

• 

The installation must always be in accordance with the applicable provisions of National Electrical Code 
ANSI/NFPA 70, article 725 and the Canadian Electrical Code part 1, section 16. The power supply shall not be 
permanently fixed to building structure or similar structure.

• 

Cette installation doit toujours être en accord avec les mesures qui s’applique au National Electrical Code 
ANSI/NFPA 70, article 725, et au Canadian Electrical Code, partie 1, section 16. La source d’alimentation ne devra pas 
être fixée de façon permanente à une structure de bâtiment ou à une structure similaire.

Summary of Contents for EBP 108 RAAP Button Panel

Page 1: ...figurator Plus and Professional GCP configuration software the Toolbelt utility software or Global Scripter programming software to configure the control processor Once configured the panels can be us...

Page 2: ...ith Global Configurator Plus and Professional or programming with Global Scripter see the software help file for more information C Volume Control LEDs and Rotary Encoder Use the encoder to adjust the...

Page 3: ...use a piece of sticky tape to pull it out of the button cap 4 Select one of the button labels from the printed label sheets included with the unit Remove the label from its backing and remove the cle...

Page 4: ...ff 22 4 3 Off 23 8 6 Off 20 1 Slide 1 2 3 4 5 6 ON M S B L S B BUS ID Figure 5 eBUS ID Setup Add the decimal numbers for each of the DIP switches that are set to On to obtain the address of the device...

Page 5: ...4 5 6 ON M S B L S B 0 0 0 1 0 0 4 1 2 3 4 5 6 ON M S B L S B 0 1 0 0 1 1 19 1 2 3 4 5 6 ON M S B L S B 0 0 0 1 0 1 5 1 2 3 4 5 6 ON M S B L S B 0 1 0 1 0 0 20 1 2 3 4 5 6 ON M S B L S B 0 0 0 1 1 0...

Page 6: ...6 1 2 3 4 5 6 ON M S B L S B 1 1 0 1 0 1 53 1 2 3 4 5 6 ON M S B L S B 1 0 0 1 0 1 37 1 2 3 4 5 6 ON M S B L S B 1 1 0 1 1 0 54 1 2 3 4 5 6 ON M S B L S B 1 0 0 1 1 0 38 1 2 3 4 5 6 ON M S B L S B 1 1...

Page 7: ...source are isolated from the devices powered by the second source by see figure 7 on the following page ATTENTION Always use a power supply supplied or specified by Extron Use of an unauthorized power...

Page 8: ...at is already powered by the IPCP Pro control processor or by an additional power supply 3 16 5 mm Max Tie drain wires to ground EBP 108 RAAP eBUS Connections Connect up to five eBUS endpoint devices...

Page 9: ...is receiving power but communication with the control processor is not confirmed Red LED Lights steadily when there is a BUS ID address conflict Green LED Lights steadily when power and communication...

Page 10: ...gure 1 on page 1 and see Step 5 Cable All Devices on page 7 6 Optional Connect cables to the AAPs Follow the instructions provided with the AAP 7 If you have not already done so set the DIP switches t...

Reviews: