background image

6

EBP 100/200 Series • Setup Guide (Continued)

eBUS port on 

an IPCP Pro 

control 

processor

+

 

V

+

 S

G

– S

eBUS port on 

an EBP or 

other eBUS 

endpoint

+

 

V

+

 S

G

– S

G

-S

+S

G

Ground

+

 Signal

-

 Signal

+

12 VDC

+V

G

-S

+S

G

-S

+S

+V

-S

+S

Tie drain wires to ground.

Ground 
all devices.

– Return

+12 VDC input

Ridged

Smooth

1A MA

X

100-240V      50-60H

z

 External

 Power Supply

(12 VDC, 1 A max.,

Extron P/N 28-071-57LF)

EBP 100 
Rear Panel

NOTE:

  Check the polarity of the power 

supply before connecting it to the EBP.

Power Input, 

External Power Supply (optional)

• Connect to an Extron 12 VDC, 1 A, 

power supply.

3/16" (5 mm) Max.

Figure 6. 

Cabling EBP Panels with an Extron 12 VDC, 1 A Power Supply

Step 6: Configure the System

NOTES:

 

• 

System configuration requires an IP network connection to the IPCP Pro. See the 

IPCP Pro Series User Guide

 for 

information about the control processors and their ports.

• 

EBP bus ID DIP switches should be set prior to uploading the configuration to the IPCP Pro.

• 

See the 

Global Configurator Help

 file as needed for step-by-step instructions and detailed information. The help file for 

GC includes an introduction to the software, and how to start a project and configuration.

1. 

Create a new Global Configurator Plus or Professional project and configure the controller and any eBUS devices. The 
configuration tells the controller how its ports function; how to control other products; what to monitor; when to do things; 
and whom to notify, how, and under what circumstances.

a. 

Configure ports on the control processor.

• 

Select device drivers and link them to each assigned port.

• 

Configure settings (serial protocol, relay behavior, digital input, volume control settings) as needed.

b. 

Set up monitors, schedules, macros, and local variables.

c. 

Set up the eBUS button panel buttons: assign appropriate commands and actions, macros, timers, local variables 
monitors, or feedback to the buttons.

2. 

Save the project.

3. 

Build and upload the system configuration to the control processor.

Step 7: Test and Troubleshoot

1. 

Verify that the DIP switches on the EBPs are set to the desired address on each unit and that there are no DIP switch address 
conflicts in the system. As mentioned in the rear panel features diagram in 

Step 4: Set Bus ID Addresses

 on page 4, the 

eBUS LED lights steadily (solid) when power and communication are present and there are no bus ID address conflicts. 

2. 

Verify that cables to and from the EBPs are wired the same at each end (pin 1 to pin 1, pin 2 to pin 2, and so forth).

3. 

Test the system.

• 

Press buttons on the EBPs and ensure the buttons light as desired and that the appropriate control commands or 
functions are triggered.

• 

Ensure that the audio output responds correctly to the 

volume

 knob or button. Also ensure that the volume LEDs light 

correctly as you increase or decrease the audio gain.

4. 

Make adjustments to wiring, bus ID address, or system configuration as needed. Remember that the rear panel ports and DIP 
switches will not be accessible after the EBP is mounted. If needed, upload a revised configuration to the control processor.

If you have questions during installation and setup, call the 

Extron S3 Sales & Technical Support Hotline

 or the Extron S3 

Control Systems Support Hotline (1.800.633.9877).

Summary of Contents for EBP 100

Page 1: ...tting bus ID DIP switches on the EBPs then using Extron Global Configurator GC Plus and Professional software or Global Scripter programming to configure the control processor Once configured the AV system can be controlled from any of its EBPs This guide provides basic instructions for an experienced installer to install an EBP 100 or EBP 200 button panel For more details on the EBPs see the EBP ...

Page 2: ...e Installation Site ATTENTION Installation and service must be performed by authorized personnel only L installation et l entretien doivent être effectués par le personnel autorisé uniquement Extron recommends installing the EBP into a grounded UL Listed electrical junction box Extron recommande d installer le EBP dans un boîtier d encastrement électrique mis à la terre listé UL If the EBP will be...

Page 3: ...late with the other hand and pulling the faceplate away from the unit 2 Gently separate the button lens button cap from its white diffuser insert the end of the provided Extron removal pry tool into the corner notch and gently twist the tool see 1 in the image at right 3 Remove the label insert from the button cap 4 Select one of the button labels from the printed label sheets included with the un...

Page 4: ...EBP 100 Rear Panel eBUS port on an IPCP Pro or on an EBP or other eBUS endpoint Figure 3 Rear Panel Features Including DIP Switch Location and Settings Each EBP in a system must have a different unique bus ID address a six bit binary number which you set by using the DIP switch assembly on the rear panel of each EBP Switch 1 on the left sets the most significant bit highest number 32 Switch 6 sets...

Page 5: ...rtifiée UL de classe 2 ou LPS et paramétré à 12 VDC et 1 0 A minimum Unless otherwise stated the AC DC adapters are not suitable for use in air handling spaces or in wall cavities Sauf mention contraire les adaptateurs AC DC ne sont pas appropriés pour une utilisation dans les espaces d aération ou dans les cavités murales The installation must always be in accordance with the applicable provision...

Page 6: ...device drivers and link them to each assigned port Configure settings serial protocol relay behavior digital input volume control settings as needed b Set up monitors schedules macros and local variables c Set up the eBUS button panel buttons assign appropriate commands and actions macros timers local variables monitors or feedback to the buttons 2 Save the project 3 Build and upload the system co...

Page 7: ...x wall or surface mounting box or mud ring as follows see 1 in figures 7 and 8 a Insert the included screws through the oval slots at the top and bottom of the EBP through the plastic spacer if not using a mud ring and into the corresponding threaded holes in the box or mud ring b Using a Phillips screwdriver lightly tighten the screws until snug Extron DISPLAY VOLUME 2 2 1 1 EBP 100 Wall Mounting...

Page 8: ... FAX Extron Asia 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511 7656 FAX Extron China 86 21 3760 1568 86 21 3760 1566 FAX Extron Middle East 971 4 299 1800 971 4 299 1880 FAX Extron Australia 61 8 8351 2188 61 8 8351 2511 FAX Extron India 1800 3070 3777 Inside India Only 91 80 3055 3777 91 80 3055 3737 FAX 2016 Extron Electronics All rights reserved All trademarks mentioned ar...

Reviews: