Contact/Tally ports operate in four modes

 depending on the needs and configuration of the user. These modes can be 

selected and configured via SIS Commands or PCS

.

 The modes are as follows:

• 

Mode 0

 — (Default) Inputs 1 through 4 are grouped and mutually exclusive. Inputs 5 and 6 are independent.

• 

Mode 1

 — Inputs 1 through 6 are independent and must be configured via SIS commands or PCS.

• 

Mode 2

 — Inputs 1 through 4 are grouped and mutually exclusive. Inputs 5 and 6 are grouped  

and mutually exclusive.

• 

Mode 3

 — Inputs 1 through 4 are mutually exclusive. Inputs 5 and 6 are in single switch mode.

Using a Show Me cable:

The Contact and Tally connectors can also be used with Extron SM Series (Show Me) cables. The 
diagram at right shows an example of how to wire an Show Me cable to a contact input.
For each Show Me cable:

• 

Connect the 

red

 pigtail to the 

C

 pin corresponding to the input being used. 

• 

Connect the 

black

 pigtail to the 

T

 pin of the same input.

9. 

Connect power 

(see 

figure 1

A

, on page 1). Connect an  

IEC power cord between the included 12 VDC, 3 A power supply and 
a 100-240 VAC, 50-60 Hz source. Use the included tie-wrap to strap 
the cord to the captive screw connector (see the diagram at right for 
wiring).
 

ATTENTION:

 

• 

The wires must be kept separate while the power supply is plugged in. Remove power before wiring.

• 

Les deux cordons d’alimentation doivent être maintenus séparés lorsque la source d’alimentation est branchée. 
Coupez l’alimentation avant d’effectuer un raccordement.

• 

The power supply must not be permanently fixed to the building structure or similar structures.

• 

La source d’alimentation ne devra pas être fixée de façon permanente à une structure de bâtiment ou à une 
structure similaire.

• 

These power supplies are not suitable for use in air handling spaces or in wall cavities.

• 

Ces sources d’alimentation ne sont pas appropriées pour une utilisation dans les espaces d’aération ou dans les 
cavités murales.

• 

Do not

 connect power to the switcher until you have read the CAUTION and ATTENTION notices on pages 5 and 6 

of the 

DTP2 T 204 User Guide

.

• 

Ne branchez pas l’alimentation au DTP2 T 204 User Guide avant d’avoir lu les mises en garde « CAUTION » et 
«ATTENTION » aux pages 5 et 6.

10. 

Power on the output display.

11. 

Power on the source devices.

Front Panel Features

R

AUTO

SWITCH

CONFIG

DTP2 T 204

INPUTS

OUTPUT

SIGNAL

HDCP

1

2

HDMI SWITCHER

1

INPUTS

3

4

w

2

4

3

C

C

C

D

D

D

F

B

B

B

A

E

Figure 2. 

DTP2 T 204 Front Panel

A

  Auto Switch LED

 — Lights when auto-input switching is in effect (see for more information). When auto-input switching is 

enabled, the switcher automatically switches to the highest-number input with an active video signal.

B 

USB Config port

 — Connect a USB cable (USB A to mini-B) between your computer and this female USB mini-B port to 

configure and control the switcher via SIS commands or PCS and to update the firmware.

Contact/Tally

Connector

Black

Red

Show Me 

Cable

C T C T +V

1

2

SECTION  A–A

Ridges

Smooth

A

A

3/16"

(5 mm) Max.

POWER

12 V         

 2.2 A MAX

Auto Switch LED

B

 

USB Config port

C

 

Input and output signal 
LEDs

HDCP LEDs

E

 

Input selection buttons

F

 

Reset button

 

 

33

Summary of Contents for DTP2 T 204

Page 1: ...put sources to one or more of the DTP2 T 204 inputs see figure 1 B The default Extron EDID is present at each input and Hot Plug Detect HPD is actively controlled on each input NOTES The default Extron EDID is 1080p 60 Hz see the DTP2 T 204 User Guide for the EDID table LockIt cable lacing brackets are provided to secure the HDMI cables to the rear panel connectors to reduce stress on the HDMI con...

Page 2: ...ugh Ethernet connect a LAN to the RJ 45 LAN connector see figure 1 H The default IP address of the scaler is 192 168 254 254 the default subnet mask is 255 255 255 0 and the default gateway address is 0 0 0 0 See the diagram in step 4 on the previous page to wire this connector 8 Optional Connect contact closure and tally indicator devices The Contact Tally section of the rear panel B on the previ...

Page 3: ... effectuer un raccordement The power supply must not be permanently fixed to the building structure or similar structures La source d alimentation ne devra pas être fixée de façon permanente à une structure de bâtiment ou à une structure similaire These power supplies are not suitable for use in air handling spaces or in wall cavities Ces sources d alimentation ne sont pas appropriées pour une uti...

Page 4: ...hese buttons are disabled but the LEDs continue to light to indicate the selected input The input buttons are also used to initiate a system reset and to enable and disable front panel lockout see the DTP2 T 204 User Guide for more information F Reset button This button initiates three modes of reset for the switcher For the different reset levels press and hold the button while the switcher is ru...

Reviews: