Extron electronics DTP DVI 230 User Manual Download Page 3

FCC Class A Notice

This equipment has been tested and found to comply with the limits for a Class A digital 
device, pursuant to part 15 of the FCC rules. The Class A limits provide reasonable 
protection against harmful interference when the equipment is operated in a commercial 
environment. This equipment generates, uses, and can radiate radio frequency energy and, 
if not installed and used in accordance with the instruction manual, may cause harmful 
interference to radio communications. Operation of this equipment in a residential area is 
likely to cause interference; correcting the interference is at the expense of the user.

ATTENTION:

 

The Twisted Pair Extension technology works with unshielded twisted pair (UTP) 

or shielded twisted pair (STP) cables; but, to ensure FCC Class A and CE compliance, STP 
cables and STP Connectors are required.
For more information on safety guidelines, regulatory compliances, EMI/EMF compatibility, 
accessibility, and related topics, see the “

Extron Safety and Regulatory Compliance 

Guide

” on the Extron website.

Specifications Availability

Product specification are available on the Extron website, 

www.extron.com

.

Conventions Used in this Guide

Notifications 

The following notifications are used in this guide:

CAUTION:

  A caution indicates a situation that may result in minor injury.

ATTENTION:

  Attention indicates a situation that may damage or destroy the product or 

associated equipment. 

NOTE:

 

A note draws attention to important information.

Copyright

© 2013  Extron Electronics. All rights reserved.

Trademarks

All trademarks mentioned in this guide are the properties of their respective owners.

The following registered trademarks

®

, registered service marks

(SM)

, and trademarks

(TM)

 are the property of 

RGB Systems, Inc. or Extron Electronics:

Registered Trademarks

 (®)

AVTrac, Cable Cubby, CrossPoint, eBUS, EDID Manager, EDID Minder, Extron, Flat Field, GlobalViewer, Hideaway, Inline, IP Intercom, IP Link, 
Key Minder, LockIt, MediaLink, PoleVault, PowerCage, PURE3, Quantum, SoundField, SpeedMount, SpeedSwitch, System Integrator, 
TeamWork, TouchLink, V‑Lock, VersaTools, VN‑Matrix,  VoiceLift, WallVault, WindoWall

Registered Service Mark

(SM)

 :  

S3 Service Support Solutions

Trademarks

 (

)

AAP, AFL (Accu‑Rate Frame Lock), ADSP (Advanced Digital Sync Processing), AIS (Advanced Instruction Set), Auto‑Image, CDRS (Class D 
Ripple Suppression), DDSP (Digital Display Sync Processing), DMI (Dynamic Motion Interpolation), Driver Configurator, DSP Configurator, DSVP 
(Digital Sync Validation Processing), FastBite, FOXBOX, IP Intercom HelpDesk, MAAP, MicroDigital, ProDSP, QS‑FPC (QuickSwitch Front Panel 
Controller), Scope‑Trigger, SIS, Simple Instruction Set, Skew‑Free, SpeedNav, Triple‑Action Switching, XTP, XTP Systems, XTRA, ZipCaddy, 
ZipClip

Summary of Contents for DTP DVI 230

Page 1: ...User Guide DTP DVI 230 HDMI DVI Extenders DVI Twisted Pair Extender 68 2341 01 Rev B 06 13...

Page 2: ...uf aufmerksam machen dass im Inneren des Geh uses dieses Produktes gef hrliche Spannungen herrschen die nicht isoliert sind und die einen elektrischen Schlag verursachen k nnen VORSICHT Dieses Symbol...

Page 3: ...ON A caution indicates a situation that may result in minor injury ATTENTION Attention indicates a situation that may damage or destroy the product or associated equipment NOTE A note draws attention...

Page 4: ......

Page 5: ...able Advantages 2 Control Communications 2 Features 2 Installation and Operation 3 Mounting the Units 3 Connections 3 Transmitter Connections 3 Receiver Connections 5 Connector and Cable Details 6 Ope...

Page 6: ...DTP DVI 230 Tx Rx Transmitter and Receiver Introduction vi...

Page 7: ...or Category CAT 5e CAT 6 or CAT 6a STP or unshielded twisted pair UTP cable The DTP DVI 230 can also extend HDMI video which may include embedded audio with the appropriate adapters The video audio a...

Page 8: ...or respond to the RS 232 and IR communication signals Features Transmits single link DVI signals over a single STP or UTP cable Standard twisted pair cables provide an economical easily installed cab...

Page 9: ...receiver installation sites which can lead to equipment damage or a missing or unstable picture If a potential difference cannot be avoided remove the ground connection between the units and locally...

Page 10: ...to this 3 5 mm 5 pole captive screw connector for bidirectional RS 232 and IR communication see RS 232 and IR connector wiring on page 9 to wire the connector e DTP Output RJ 45 connector Connect one...

Page 11: ...captive screw connector outputs the transmitted unamplified line level analog audio Connect an audio device such as an audio amplifier or powered speakers See figure 4 to properly wire a captive scre...

Page 12: ...er and normally can power both units If you have removed the ground jumpers see Disconnecting the Ground on page 11 because of ground potential differences one DTP DVI 230 unit cannot remotely power t...

Page 13: ...Package of 10 101 005 02 If not using XTP DTP 24 cable at a minimum Extron recommends 24 AWG solid conductor STP cable with a minimum bandwidth of 400 MHz Terminate cables with shielded connectors to...

Page 14: ...connector NOTES on page 5 for details ATTENTION This product is intended to be supplied by a Listed Power Unit marked Class 2 or LPS rated 12 VDC 1 0 A minimum Always use a power supply supplied by o...

Page 15: ...l Amber The unit is receiving power either locally or remotely on the DTP cable Green The unit is receiving an active DVI input either on the DVI input if a transmitter or transmitted on the DTP cable...

Page 16: ...ing or unstable picture If a potential difference cannot be avoided remove the ground connection between the units and locally power both units see Disconnecting the Ground on the next page The 1 inch...

Page 17: ...onsideration of equipment nameplate ratings should be used when addressing this concern Reliable earthing grounding Reliable earthing of rack mounted equipment should be maintained Particular attentio...

Page 18: ...curing them in place with the screws removed in step 2 5 Reinstall both units in their racks or other installation option see Mounting the Transmitter and Receiver on page 10 6 If you are using shield...

Page 19: ...Hanzeboulevard 10 3825 PH Amersfoort The Netherlands China Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China Asia Extron Asia Pte Ltd 135 Joo Seng Road 04 01 PM Industrial Bldg S...

Reviews: