Extron electronics DTP DVI 230 User Manual Download Page 10

 

DTP DVI 230 Tx/Rx Transmitter and Receiver • Installation and Operation

4

b

 

Local Output connector

 — If desired, connect a DVI monitor for local monitoring of 

the input digital image.

NOTES:

• 

The local output is limited to a data rate of 4.95 Gbps (1.65 Gbps per color).

• 

In a system where the local output is not used, ensure that you power up the 
end display first before the video source. Route the DDC to the remote end 
(see the DDC Route DIP switch [see 

item 

c

 on page 9]).

c

 

Audio input connector

 — If desired, plug an analog audio input into the transmitter 

via this stereo mini jack connector.

NOTE:

  The analog audio input on this connector is in 

addition to the digital audio that may be embedded 
in the DVI input. See the figure at right to identify 
the connector tip, ring, and sleeve when you 
are making connections for the transmitter from 
existing audio cables. A mono audio connector 
consists of the tip and sleeve. A stereo audio 
connector consists of the tip, ring, and sleeve.

Sleeve (   )

Ring (-)

Tip (+)

3.5 mm Stereo Plug Connector

(balanced)

d

 

RS-232 and IR connector

 — Connect a serial RS‑232 signal, a modulated IR 

signal, or both to this 3.5 mm, 5‑pole captive screw connector for bidirectional RS‑232 
and IR communication (see 

RS-232 and IR connector wiring

 on page 9

 

to wire the 

connector).

e

 

DTP Output RJ-45 connector

 — Connect one end of a TP cable to this RJ‑45 

female connector on the transmitter. Ensure the opposite end of this cable is connected 
to the receiver DTP Input RJ‑45 connector (see 

item 

g

 on the next page).

ATTENTION:

  Do not connect this device to a telecommunications or computer 

data network.

NOTE:

 See 

TP cable termination and recommendations

 on page 6 to properly 

wire the RJ‑45 connectors and for detailed 

NOTES

.

Signal LED

 — Indicates the unit is receiving a TMDS clock signal on the DVI input.

Link LED

 — Indicates a valid link is established between the units on the DTP input 

and output cable.

f

 

Power input connector

 — Plug the included external 12 VDC power supply into 

either this 2‑pole connector 

or

 the power input connector on the receiver (

item 

k

 on 

page 6). See 

Power supply wiring

 on page 8

 

to wire the connector.

NOTES:

• 

One power supply is included with the transmitter and 

normally

 can power 

both units.

• 

If you have removed the ground jumpers (see 

Disconnecting the Ground

 

on page 11) because of ground potential differences, one DTP DVI 230 unit 

cannot

 remotely power the other unit. Each unit 

requires

 a local power 

supply.

Summary of Contents for DTP DVI 230

Page 1: ...User Guide DTP DVI 230 HDMI DVI Extenders DVI Twisted Pair Extender 68 2341 01 Rev B 06 13...

Page 2: ...uf aufmerksam machen dass im Inneren des Geh uses dieses Produktes gef hrliche Spannungen herrschen die nicht isoliert sind und die einen elektrischen Schlag verursachen k nnen VORSICHT Dieses Symbol...

Page 3: ...ON A caution indicates a situation that may result in minor injury ATTENTION Attention indicates a situation that may damage or destroy the product or associated equipment NOTE A note draws attention...

Page 4: ......

Page 5: ...able Advantages 2 Control Communications 2 Features 2 Installation and Operation 3 Mounting the Units 3 Connections 3 Transmitter Connections 3 Receiver Connections 5 Connector and Cable Details 6 Ope...

Page 6: ...DTP DVI 230 Tx Rx Transmitter and Receiver Introduction vi...

Page 7: ...or Category CAT 5e CAT 6 or CAT 6a STP or unshielded twisted pair UTP cable The DTP DVI 230 can also extend HDMI video which may include embedded audio with the appropriate adapters The video audio a...

Page 8: ...or respond to the RS 232 and IR communication signals Features Transmits single link DVI signals over a single STP or UTP cable Standard twisted pair cables provide an economical easily installed cab...

Page 9: ...receiver installation sites which can lead to equipment damage or a missing or unstable picture If a potential difference cannot be avoided remove the ground connection between the units and locally...

Page 10: ...to this 3 5 mm 5 pole captive screw connector for bidirectional RS 232 and IR communication see RS 232 and IR connector wiring on page 9 to wire the connector e DTP Output RJ 45 connector Connect one...

Page 11: ...captive screw connector outputs the transmitted unamplified line level analog audio Connect an audio device such as an audio amplifier or powered speakers See figure 4 to properly wire a captive scre...

Page 12: ...er and normally can power both units If you have removed the ground jumpers see Disconnecting the Ground on page 11 because of ground potential differences one DTP DVI 230 unit cannot remotely power t...

Page 13: ...Package of 10 101 005 02 If not using XTP DTP 24 cable at a minimum Extron recommends 24 AWG solid conductor STP cable with a minimum bandwidth of 400 MHz Terminate cables with shielded connectors to...

Page 14: ...connector NOTES on page 5 for details ATTENTION This product is intended to be supplied by a Listed Power Unit marked Class 2 or LPS rated 12 VDC 1 0 A minimum Always use a power supply supplied by o...

Page 15: ...l Amber The unit is receiving power either locally or remotely on the DTP cable Green The unit is receiving an active DVI input either on the DVI input if a transmitter or transmitted on the DTP cable...

Page 16: ...ing or unstable picture If a potential difference cannot be avoided remove the ground connection between the units and locally power both units see Disconnecting the Ground on the next page The 1 inch...

Page 17: ...onsideration of equipment nameplate ratings should be used when addressing this concern Reliable earthing grounding Reliable earthing of rack mounted equipment should be maintained Particular attentio...

Page 18: ...curing them in place with the screws removed in step 2 5 Reinstall both units in their racks or other installation option see Mounting the Transmitter and Receiver on page 10 6 If you are using shield...

Page 19: ...Hanzeboulevard 10 3825 PH Amersfoort The Netherlands China Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China Asia Extron Asia Pte Ltd 135 Joo Seng Road 04 01 PM Industrial Bldg S...

Reviews: