UL Rack-Mounting Guidelines

The following Underwriters Laboratories (UL) requirements pertain to the installation of the 
unit into a rack.

• 

Elevated operating ambient temperature

 — If installed in a closed or multi‑unit rack 

assembly, the operating ambient temperature of the rack environment may be greater 
than room ambient. Therefore, consider installing the equipment in an environment 
compatible with the maximum ambient temperature (TMA = +122 °F, +50 °C) specified 
by Extron.

• 

Reduced air flow

 — Installation of the equipment in a rack should be such that the 

amount of air flow required for safe operation of the equipment is not compromised.

• 

Mechanical loading

 — Mounting of the equipment in the rack should be such that a 

hazardous condition is not achieved due to uneven mechanical loading.

• 

Circuit overloading

 — Consideration should be given to the connection of the 

equipment to the supply circuit and the effect that overloading of the circuits might have 
on overcurrent protection and supply wiring. Appropriate consideration of equipment 
nameplate ratings should be used when addressing this concern.

• 

Reliable earthing (grounding)

 — Reliable earthing of rack‑mounted equipment 

should be maintained. Particular attention should be given to supply connections other 
than direct connections to the branch circuit (such as use of power strips).

Disconnecting the Ground

If you cannot resolve a ground potential difference between the transmitter and receiver 
installation sites (as suggested by a missing or unstable picture), remove the ground 
connection between the units as follows:

NOTE:

 Once 

you have removed the ground jumpers, the DTP DVI 230 

cannot

 extend 

analog audio and one unit 

cannot

 remotely power the other. 

No

 analog audio is 

output and each unit 

requires

 a local power supply.

1. 

Disconnect any cables and remove the transmitter and receiver from any rack or other 
installation option.

2. 

Remove and retain the screws securing the covers to the transmitter and receiver. Slide 
the covers forward slightly and lift them off both units (see figure 9).

• 

Transmitter

 — Six screws, two on each side and two on top

• 

Receiver

 — Eight screws, three on each side and two on top

Cover Screws

(8 Plcs)

Cover Screws

(6 Plcs)

Transmitter

Receiver

Rear Panel

Rear Panel

Figure 9. 

Opening the Transmitter and Receiver

Summary of Contents for DTP DVI 230

Page 1: ...User Guide DTP DVI 230 HDMI DVI Extenders DVI Twisted Pair Extender 68 2341 01 Rev B 06 13...

Page 2: ...uf aufmerksam machen dass im Inneren des Geh uses dieses Produktes gef hrliche Spannungen herrschen die nicht isoliert sind und die einen elektrischen Schlag verursachen k nnen VORSICHT Dieses Symbol...

Page 3: ...ON A caution indicates a situation that may result in minor injury ATTENTION Attention indicates a situation that may damage or destroy the product or associated equipment NOTE A note draws attention...

Page 4: ......

Page 5: ...able Advantages 2 Control Communications 2 Features 2 Installation and Operation 3 Mounting the Units 3 Connections 3 Transmitter Connections 3 Receiver Connections 5 Connector and Cable Details 6 Ope...

Page 6: ...DTP DVI 230 Tx Rx Transmitter and Receiver Introduction vi...

Page 7: ...or Category CAT 5e CAT 6 or CAT 6a STP or unshielded twisted pair UTP cable The DTP DVI 230 can also extend HDMI video which may include embedded audio with the appropriate adapters The video audio a...

Page 8: ...or respond to the RS 232 and IR communication signals Features Transmits single link DVI signals over a single STP or UTP cable Standard twisted pair cables provide an economical easily installed cab...

Page 9: ...receiver installation sites which can lead to equipment damage or a missing or unstable picture If a potential difference cannot be avoided remove the ground connection between the units and locally...

Page 10: ...to this 3 5 mm 5 pole captive screw connector for bidirectional RS 232 and IR communication see RS 232 and IR connector wiring on page 9 to wire the connector e DTP Output RJ 45 connector Connect one...

Page 11: ...captive screw connector outputs the transmitted unamplified line level analog audio Connect an audio device such as an audio amplifier or powered speakers See figure 4 to properly wire a captive scre...

Page 12: ...er and normally can power both units If you have removed the ground jumpers see Disconnecting the Ground on page 11 because of ground potential differences one DTP DVI 230 unit cannot remotely power t...

Page 13: ...Package of 10 101 005 02 If not using XTP DTP 24 cable at a minimum Extron recommends 24 AWG solid conductor STP cable with a minimum bandwidth of 400 MHz Terminate cables with shielded connectors to...

Page 14: ...connector NOTES on page 5 for details ATTENTION This product is intended to be supplied by a Listed Power Unit marked Class 2 or LPS rated 12 VDC 1 0 A minimum Always use a power supply supplied by o...

Page 15: ...l Amber The unit is receiving power either locally or remotely on the DTP cable Green The unit is receiving an active DVI input either on the DVI input if a transmitter or transmitted on the DTP cable...

Page 16: ...ing or unstable picture If a potential difference cannot be avoided remove the ground connection between the units and locally power both units see Disconnecting the Ground on the next page The 1 inch...

Page 17: ...onsideration of equipment nameplate ratings should be used when addressing this concern Reliable earthing grounding Reliable earthing of rack mounted equipment should be maintained Particular attentio...

Page 18: ...curing them in place with the screws removed in step 2 5 Reinstall both units in their racks or other installation option see Mounting the Transmitter and Receiver on page 10 6 If you are using shield...

Page 19: ...Hanzeboulevard 10 3825 PH Amersfoort The Netherlands China Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China Asia Extron Asia Pte Ltd 135 Joo Seng Road 04 01 PM Industrial Bldg S...

Reviews: