DMP 64 Plus• SIS Configuration and Control
40
X3#
=
Action Type
—
0
= No action/off
Mutes
1
= Level trigger (low mutes)
2
= Level trigger (high mutes)
3
= Edge trigger (high to low mutes, low to high unmutes)
4
= Edge trigger (high to low unmutes, low to high mutes)
5
= Toggle trigger (high to low toggles mute)
6
= Toggle trigger (low to high toggles mute)
Group Mutes
7
= Level trigger (low mutes)
8
= Level trigger (high mutes)
9
= Edge trigger (high to low mutes, low to high unmutes)
10
= Edge trigger (high to low unmutes, low to high mutes)
11
= Toggle trigger (high to low toggles mute)
12
= Toggle trigger (low to high toggles mute)
Macros
13
= Edge trigger (high to low starts macro)
14
= Edge trigger (low to high starts macro
Presets
15
= Edge trigger (high to low recalls preset)
16
= Edge trigger (low to high recalls preset)
X3$
=
Varies according to the action type
Mutes
Input number for muting.
If
X3#
is not specified, muting matches the input with the corresponding I/O channel number.
Group Mutes
Group member for muting.
If
X3#
is not specified, muting matches the group with the corresponding I/O channel number.
Macros
Macro number.
If
X3#
is not specified, the macro number defaults to the corresponding I/O channel number.
Presets
Preset number.
If
X3#
is not provided, the preset number defaults to the corresponding I/O channel number.
X3%
=
Digital Output
—
1
X3^
=
Output Mode
—
0
= Output always high
1
= Output always low
Mutes
2
= Mute high
3
= Unmute high
Group Mutes
4
= Group mute high
5
= Group unmute high
Macros
6
= Macro started set high once (blink)
7
= Macro started set low once (blink)
Presets
8
= Presets recalled set high once (blink)
9
= Preset recalled set low once (blink)
Automix Gate Status
10
= Automix gate on (>1024) set high
11
= Automix gate on (>1024) set low
Signal Presence
12
= Signal presence (>-40 dBFS) set high
13
= Signal presence (>-40 dBFS) set low