Installation Checklist

 

…

Planning

 

(page 1)

 

…

Check with local and state regulations before starting the installation.

 

…

Check all parts and equipment before installation.

 

…

Preparing the Table (page 2)

 

…

Determine the best location for the enclosure

.

 

…

Choose a method for cutting the hole in the table.

 

…

Preparing the Cable Cubby (page 3-5)

 

…

Assemble connectivity modules

 

(page 3).

 

…

Install the modules

 

(page 5).

 

…

Mounting the Cable Cubby in the Table (page 5)

 

…

Mount the Cable Cubby flush with the table

.

 

…

Adjust the side clamps under the table.

 

…

Installing Retractors (page 7)

 

…

Routing and Connecting Cables (page 8)

Routing and Connecting Cables

CAUTION:

 

Risk of Electric Shock

.  

This equipment must be grounded.

ATTENTION :

 

Risque de choc électrique

.  

Cet équipement doit être fixé au sol.

NOTE:

 

Ensure that there is no tension on the power 

cable.

Connect cables to the AV system 

and connect the AC power cord.

3

Using zip ties, secure cables to the holes 

on the bottom of the Cable Cubby.

2

For cable pass-through applications, 

allow at least 36 inches (0.9 m) of cable 

loop for each cable.

1

Summary of Contents for Cable Cubby 1202

Page 1: ...th local and state regulations before starting the installation Ensure that the planned installation complies with national and local building and electrical codes Ensure that the planned installation complies with the Americans with Disabilities Act or other accessibility requirements Check all parts and equipment before installation Ensure that all parts are present in each kit Ensure that neces...

Page 2: ...space under the table for cables Allow at least 36 inches of cable loop for each cable see Routing and Connecting Cables on page 8 When installing Retractors in the Cable Cubby ensure that there is enough space for the Retractor assembly under the table or furniture see the Retractor dimensions in the images below or go to www extron com Retractor dimensions NOTE Shown with Cable Cubby 1202 enclos...

Page 3: ...upée seulement par des artisans autorisés et qualifiés Faites attention à ne pas faire de marques sur le meuble et à ne pas l endommager Choose one of the following methods for cutting the hole Hand Router and Routing Template Jigsaw and Paper Cut Out Template CNC Wood Router If using a CNC wood router or other precise machinery use the exact cut out dimensions for your model see the table below V...

Page 4: ...d for vertical or angular Retractor mounting in a Cable Cubby 1402 Option 3b Use this option for horizontal Retractor mounting in a Cable Cubby 1402 only Secure the grommet plate on the connectivity bracket using four of the provided module screws Insert cables through the bottom of the connectivity bracket and into the holes of the grommet plate Snap the included hole plugs into any unused holes ...

Page 5: ...o close completely Use a screwdriver to secure the modules with the screws Insert the modules into the Cable Cubby 1 Secure the modules using four of the provided pan head mounting screws and star washers 2 12 5V 50 6 0H z 12 A M AX TO TA L TOP Cable Cubby 1202 WARNING Risk of Electric Shock To ensure proper electrical grounding use the provided 6 32 mounting screws with the star washers AVERTISSE...

Page 6: ...ble CAUTION The flanged edges of the top of the surface enclosure are sharp These edges are also soft and may be easily nicked or bent Exercise caution when handling the enclosure to prevent personal injury or damage to the enclosure ATTENTION Les extrémités à brides du haut de la surface du boîtier sont aiguisées Ces extrémités sont aussi lisses et peuvent facilement être coupées ou pliées Soyez ...

Page 7: ...re the clip on the pin Insert Retractors into the Retractor bracket Secure the locking screw on each Retractor Do not overtighten 2 1 4 3 p Pin Clip Angular Mounting Remove the enclosure screws as shown above then follow this step Horizontal Mounting See the Cable Retractor Series 2 Setup Guide available on the Extron website for additional steps Remove two enclosure screws one on each side from t...

Page 8: ...e best location for the enclosure Choose a method for cutting the hole in the table Preparing the Cable Cubby page 3 5 Assemble connectivity modules page 3 Install the modules page 5 Mounting the Cable Cubby in the Table page 5 Mount the Cable Cubby flush with the table Adjust the side clamps under the table Installing Retractors page 7 Routing and Connecting Cables page 8 Routing and Connecting C...