background image

Technical Specifications

9

Extreme Networks Data Sheet: 

Summit X250e Series

General Specifications

Performance

97.6 Gbps switch fabric bandwidth 
39.9 Mpps frame forwarding rate 
9,216 Byte maximum packet size (Jumbo Frame) 
128 load sharing trunks, up to 8 members per trunk 
8 QoS queues/port 
4,094 VLANs (Port, Protocol, IEEE 802.1Q) 
1,024 centralized ACL rules per 24-port 

Forwarding Tables 

Layer 2/MAC Addresses: 8K 
IPv4 LPM Entries: 512 
IPv6 LPM Entries: 256  

Summit X250e-48p

Heat Dissipation (with PoE full load): 100W (341 BTU/h)
Power Consumption (with PoE full load): 470W (1604 BTU/h)
Heat Dissipation (without PoE): 55W (188 BTU/h) 
Power Consumption (without PoE): 55W (188 BTU/h)
Acoustic Noise (Low FAN Speed): 39 dBA per ISO 7779 
Acoustic Noise (High FAN Speed): 44 dBA per ISO 7779 

Ingress bandwidth policing/rate limiting per flow 
Egress bandwidth rate shaping per egress queue and per port
Rate Limiting Granularity: 64Kbps 
Available Rate Limiters: 1,024 per switch  

Indicators 

Per port status LED 
System Status LEDs: management, fan and power  

Ports 

48 ports 10/100BASE-T PoE with auto-speed and auto-polarity 
2 ports Gigabit Ethernet (SFP shared PHY with 2 10/100/1000BASE-T 
ports) 
2 SummitStack stacking interfaces 
1 port serial (console port) 
1 10/100BASE-T out-of-band management port 

External Power Supply Support

EPS-C with EPS-600LS

External Power Supply–EPS-C Chassis accepts up to three EPS-600LS 
power modules and provides the following capability depending upon 
the number of EPS 600LS installed
•  One EPS-600LS

 

Redundant, up to 370W PoE power

•  Two EPS-600LS

 

Redundant, up to 370W PoE power

 

Non-Redundant, up to 740W PoE power 

•  Three EPS-600LS
Redundant, up to 740W PoE power 

Physical Specifications 

Dimensions and Weight

Height: 1.73 Inches/4.4 Cm 
Width: 17.35 Inches/44.1 Cm 
Depth: 15.28 Inches/38.8 Cm 
Weight: 12.06 lbs/5.48 Kg  

Operating Specifications

Power & Acoustic Sound 

Voltage Input Range: 90 – 264V 
Nominal Input Ratings: 100 – 240V~, 50/60Hz, 5.5A
Input Current (with PoE full load):  
4.5A @ 115V~ (lowline)  
2.25A @ 230V~ (highline) 
Input Current (without PoE):  
0.75A @ 115V~ (lowline)  
0.5A @ 230V~ (highline)
Maximum In-Rush Current: 30A @ 115V, 60A @ 230V
Efficiency: 78% with 60% – 100% load
Line Frequency Range: 47 – 63 Hz 
Power Supply Input Socket: IEC 320 C14 
Power Cord Input Plug: IEC 320 C13 
Heat Dissipation (with PoE full load): 130W (444 BTU/h)
Power Consumption (with PoE full load): 525W (1,791 BTU/h)
Heat Dissipation (without PoE): 75W (256 BTU/h) 
Power Consumption (without PoE): 75W (256 BTU/h)
Acoustic Noise (Low FAN Speed): 39 dBA per ISO 7779 
Acoustic Noise (High FAN Speed): 46 dBA per ISO 7779

Operating Specifications

Power & Acoustic Sound 

Voltage Input Range: 90 – 264V 
Nominal Input Ratings: 100 – 240V~, 50/60Hz, 5.5A
Input Current (with PoE full load): 4.4A @ 115V~ (lowline) 2.2A @ 
230V~ (high-line) 
Input Current (without PoE): 0.75A @ 115V~ (lowline) 0.5A @ 230V~ 
(high-line) 
Maximum In-Rush Current: 30A @115V, 60A @230V
Efficiency: 81% with 60% – 100% load
Line Frequency Range: 47 – 63 Hz 
Nominal Frequency Range: 50 – 60 Hz 
Power Supply Input Socket: IEC 320 C14 
Power Cord Input Plug: IEC 320 C13 

General Specifications ( continued )

Summary of Contents for Summit X250e Series

Page 1: ...rtification Highlights Summit X250e series switches are based on Extreme Networks revolutionary ExtremeXOS core class operating system ExtremeXOS is a highly resilient modular operating system that helps provide continuous uptime manageability and operational efficiency at an affordable price Summit X250e provides high availability and performance with its advanced traffic management capabilities ...

Page 2: ...t Multipath Routing Equal Cost Multipath ECMP routing allows uplinks to be load balanced for performance and cost savings while also supporting redundant failover If an uplink fails traffic is automatically routed to the remaining uplinks and connectivity is maintained Link Aggregation 802 3ad Link aggregation allows trunking of up to eight links on a single logical connection for up to 2 Gigabits...

Page 3: ...s Granular QoS low latency and low jitter enable voice quality connections Summit X250e supports a range of QoS technologies that can prioritize and predictably handle high priority traffic policing or rate limiting on ingress 802 1Q tagging and Diffserv marking and shaping on egress with eight queues per port The Extreme Networks tradition of building products with low latency and jitter continue...

Page 4: ...files based on organizational structure or other logical groupings and apply them across multiple users to allow appropriate access to network resources In addition support for Wide Key ACLs further improves security by going beyond the typical source destination and MAC address as identification criteria access mechanism to provide filtering capabilities Host Integrity Checking Host integrity che...

Page 5: ...rity scalability availability mobility or management Edge Connectivity for Advanced Carrier Ethernet Applications Carrier Ethernet edge switching with 100BASE X provides advanced fiber connectivity to the customer Summit X250e is deployed as an intelligent Fast Ethernet edge switch extending the benefits of the ExtremeXOS operating system to the network edge in the Carrier Ethernet network This un...

Page 6: ...50DC and EPS T2 EPS 150DC is the redundant DC Power Supply for DC PSU based Summit switches The EPS T2 power tray is required to rack mount this external power supply EPS T2 power tray can take up to two EPS 150DC power modules and each EPS 150DC works individually EPS 150DC comes with a DC output cable to connect between the Summit switch and EPS 150DC Front View Front View Front View Front View ...

Page 7: ...with 60 100 load Line Frequency Range 47 63 Hz Power Supply Input Socket IEC 320 C14 Summit X250e 48t General Specifications Performance 97 6 Gbps switch fabric bandwidth 39 9 Mpps frame forwarding rate 9 216 Byte maximum packet size Jumbo Frame 128 load sharing trunks up to 8 members per trunk 8 QoS queues port 4 094 VLANs Port Protocol IEEE 802 1Q 1 024 centralized ACL rules per 24 port Forwardi...

Page 8: ...67 2 BTU h Power Consumption 49W 167 2 BTU h Acoustic Noise Low FAN Speed 37 dBA per ISO 7779 Acoustic Noise High FAN Speed 45 dBA per ISO 7779 Indicators Per port status LED System Status LEDs management fan and power Ports 24 ports 10 100BASE T PoE with auto speed and auto polarity 2 ports Gigabit Ethernet 100 1000BASE X SFP shared PHY with 2 10 100 1000BASE T ports 2 SummitStack stacking interf...

Page 9: ...following capability depending upon the number of EPS 600LS installed One EPS 600LS Redundant up to 370W PoE power Two EPS 600LS Redundant up to 370W PoE power Non Redundant up to 740W PoE power Three EPS 600LS Redundant up to 740W PoE power Physical Specifications Dimensions and Weight Height 1 73 Inches 4 4 Cm Width 17 35 Inches 44 1 Cm Depth 15 28 Inches 38 8 Cm Weight 12 06 lbs 5 48 Kg Operati...

Page 10: ...on 31W 105 8 BTU h Acoustic Noise Low FAN Speed 37 dBA per ISO 7779 Acoustic Noise High FAN Speed 45 dBA per ISO 7779 Summit X250e 24tDC General Specifications Performance 97 6 Gbps switch fabric bandwidth 39 9 Mpps frame forwarding rate 9 216 Byte maximum packet size Jumbo Frame 128 load sharing trunks up to 8 members per trunk 8 QoS queues port 4 094 VLANs Port Protocol IEEE 802 1Q 1 024 central...

Page 11: ...rds North American Safety of ITE UL 60950 1 1st Ed Listed Device U S CSA 22 2 60950 1 03 1st Ed Canada Complies with FCC 21CFR 1040 10 U S Laser Safety CDRH Letter of Approval U S FDA Approval European Safety of ITE EN60950 1 2001 A11 EN 60825 1 A2 2001 Lasers Safety TUV R GS Mark by German Notified Body 2006 95 EC Low Voltage Directive International Safety of ITE CB Report Certificate per IEC 609...

Page 12: ...erational Shock Half Sine 30 m s2 3g 11ms 60 Shocks Operational Random Vibration 5 500 Hz 1 5g rms Storage Transportation Conditions Packaged Transportation Temperature 40 C to 70 C 40 F to 158 F Storage and Transportation Humidity 10 to 95 RH non condensing Packaged Shock Half Sine 180 m s2 18g 6ms 600 shocks Packaged Sine Vibration 5 62 Hz Velocity 5mm s 62 500 Hz 0 2 G Packaged Random Vibration...

Page 13: ... 320 C13 Heat Dissipation 158W 539 1 BTU h Power Consumption 659W 2448 6 BTU h Dimensions and Weight EPS C Height 1 73 Inches 4 4 Cm Width 17 32 Inches 44 0 Cm Depth 11 81 Inches 30 0 Cm Weight 7 17 Lbs 3 16 Kg EPS 600LS Height 1 69 Inches 4 3 Cm Width 4 61 Inches 11 7 Cm Depth 11 81 Inches 30 9 Cm Weight 3 74 Lbs 1 70 Kg Power EPS 600LS Voltage Input Range 90 264 V Nominal Input Voltage Hz 115V 6...

Page 14: ...dundant power system chassis requires EPS 600LS 15107T Summit X250e 48p TAA U S Federal TAA 48 10 100BASE TX with PoE 2 gigabit combo ports 2 unpopulated gigabit SFP and 10 100 1000BASE T 2 SummitStack stacking ports ExtremeXOS Edge license 1 AC PSU connector for EPS C external redundant power system chassis requires EPS 600LS 15109 Summit X250e 24x 24 100BASE X SFP 2 gigabit combo ports 2 unpopul...

Page 15: ...EPS 150DC power modules Add one EPS 150DC for each redundantly powered system 10051 SX SFP 1000BASE S SFP 1000BASE SX LC Connector 10052 LX SFP External Power System 500 Watts Power cord ordered separately 10053 ZX SFP 1000BASE ZX SFP Extra Long Distance SMF 70 km 21 dB Budget LC Connector 10064 LX100 SFP 1000BASE LX100 SFP Extra Long Distance SMF 100 km 30 dB Budget LC Connector 10056 1000BX SFP ...