TABLE 13
SLX 9540 Switch LED
Indications (continued)
LED Function/state
Meaning
Possible cause
Activity Green LED
OFF
ON
Indicates activity
No Activity
Activity
The Ethernet LEDs are integrated with the RJ45
connector and are driven by the respective
Ethernet Phys.
Link Green LED
ON
OFF
Indicates link status
Link
No link
Power Supply Input Status (On PSU)
Off
Unit is OFF or FAULT condition
- Input Voltage is Above over voltage range or
Below under voltage range
- No input Power present
Green Blinking
OV/UV warning
Input voltage is in OV or UV warning range
Green Steady
OK
Input voltage is nominal.
Power Supply Output Status (On PSU)
Off
No Power
Green Blinking
Stand-By
Standby output enabled with no power supply
warning or fault detected
Green Steady
Power GOOD
Main output and standby output enabled with no
power supply warning or fault detected
Amber Blinking
Warning
Power supply warning detected as per PMBus
STATUS_X reporting bytes
Amber Steady
FAULT
Power supply fault detected as per PMBus
STATYS_X reporting bytes
Fan Status LED (On Fan FRU)
Off
No Power
Green Steady
Fan operates per specification
Green Blinking
Amber Steady
Fan failed
Amber Blinking
10G/100G Port LEDs (Green only)
Solid Off
No Link
Solid ON
Link, no traffic
Link, traffic
Activities
All LEDs (and the chassis LED)
On 1 sec, Off 1 sec
Chassis Beaconing
One port LED on 2 sec, Off 2 sec
Indicates a particular port fault.
A port LED will blink on for two seconds and off
for two seconds at a time when a local fault is
detected. Confirm local faults with the CLI:
flex-
cli show local-fault
. To clear LED in this state,
configure
shutdown
followed by
no shutdown
on the affected interface.
Home Run Port LEDs (Amber only. Note: This LED is shared with SFP Port 48 LED)
Solid Off
No Link
Solid Amber ON
Link, no traffic
Amber Flicker
Link, Activity
LED indications
ExtremeSwitching SLX 9540 Hardware Installation Guide
9036360-00 Rev AB
75
Summary of Contents for ExtremeSwitching SLX 9540
Page 1: ...ExtremeSwitching SLX 9540 Hardware Installation Guide 9036306 00 Rev AB March 2020 ...
Page 6: ...ExtremeSwitching SLX 9540 Hardware Installation Guide 6 9036360 00 Rev AB ...
Page 10: ...ExtremeSwitching SLX 9540 Hardware Installation Guide 10 9036360 00 Rev AB ...
Page 72: ...ExtremeSwitching SLX 9540 Hardware Installation Guide 72 9036360 00 Rev AB ...
Page 76: ...ExtremeSwitching SLX 9540 Hardware Installation Guide 76 9036360 00 Rev AB ...
Page 90: ...ExtremeSwitching SLX 9540 Hardware Installation Guide 90 9036360 00 Rev AB ...
Page 96: ...ExtremeSwitching SLX 9540 Hardware Installation Guide 96 9036360 00 Rev AB ...