Label
Description
A
Long slots on the sides of the pole part of the
KT-1474017-02 bracket. These slots are used to insert
the 0.5" stainless-steel cable clamps.
5 Attach the pole bracket to a pole by positioning the cable clamps on the pole bracket around a pole.
6 Insert the ends of the cable clamps around the pole and tighten the clamp screws to a torque of 11
in-lbs.
Attaching the access point to a pole using the pole part of the KT-147407-02
bracket
If the 1-axis tilt is not required, you can attach the pole part of the KT-147407-02 bracket to the access
point.
The following hardware is required:
•
Pole part of the KT-147407-02 access point
•
Two 0.5" wide stainless-steel cable clamps
•
Access point
•
Four M6 hex-head screws
To mount the access point on to a pole using only the pole part of the KT-147407-02 bracket:
1 Attach the pole part of the KT-147407-02 bracket to the access point using four M6 hex-head
screws.
Use the semi-circular cuts on the pole part of the KT-147407-02 bracket to attach the screws.
Figure 14: Semi circular cuts on the pole part of the KT-147407-02 bracket
Install the Access Point
ExtremeMobility AP460i/e Outdoor Access Points
24