If you are going to use an IPv6 address, enter the network information in colon-separated notation
as prompted after the
ipv6 address
operand.
device(config)# interface Management 1
device(config-Management-1)# no ip address dhcp
device(config-Management-1)# ipv6 address \
fd00:60:69bc:832:e61f:13ff:fe67:4b94/64
5. Return to privileged EXEC mode by entering
exit
.
device(config)# exit
device#
6. To display the configuration, use the
show running-config interface Management
command.
device# show running-config interface Management 1
interface Management 1
no ip address dhcp
ip address 10.24.85.81/20
ipv6 address fd00:60:69bc:832:e61f:13ff:fe67:4b94/64
!
Establishing an Ethernet connection
After using a serial connection to configure the IP addresses for the device, you can connect the active
management module to the local area network (LAN).
Note
Connecting interface modules to a private network or VLAN is recommended.
After establishing an Ethernet connection, you can complete the device configuration using a serial
console connection, Telnet connection, or existing management applications.
Perform the following steps to establish an Ethernet connection to the device.
1. Remove the shipping plug from the Ethernet port on the active management module.
The active management module has the LED labeled ACTIVE on the front panel illuminated in blue.
Initial Setup and Verification
Establishing an Ethernet connection
ExtremeRouting SLX 9640 Hardware Installation Guide
59