The following table describes the regulatory AC power specifications for the VSP 8000 Series. Note
that regulatory power specifications are based on the maximum rated capacity of the power supplies
and are not based on typical power consumption, which is typically lower.
Table 14: AC power specifications
VSP 8000 Series
Input Current:
9.9–4.79 A
Input Voltage (rms):
100–240 V, 47–63 Hz
Power Consumption:
800 W maximum
Thermal Rating:
2730 BTU/Hr maximum
Inrush Current:
40 A maximum
Turn on Condition:
1 second maximum after application of AC power
Important:
12 V output rise time, from 10 to 90 percent, must be the maximum of 50 ms and monotonic under all
defined input and output conditions.
Efficiency:
70 percent minimum
AC power cord specifications
To connect AC power to the switch, you need an appropriate AC power cord as described in the
following table, also see the following table for plug specifications.
Table 15: International power cord specifications
Country and Plug Specification
Specifications
Typical Plug
Continental Europe:
• CEE7 standard VII male plug
• Harmonized cord (HAR marking on the outside of the cord
jacket to comply with the CENELEC Harmonized
Document HD-21)
• 220 or 230VAC
• 50 Hz
• Single phase
United States of America, Canada, and Japan:
• NEMA5-15P male plug
• UL-recognized (UL stamped on cord jacket)
• CSA-certified (CSA label secured to the cord)
• 100 or 120VAC
• 50–60 Hz
• Single phase
Table continues…