4. Insert and tighten the rack-mount screws.
Cable requirements for the Virtual Services Platform 4000
The following table describes the cables required for the VSP 4000 switch.
Table 7: Switch cable requirements
Required Cable
Description
10/100/1000BASE-T Ports
The interconnect cabling must conform to the Cat5e, Cat6, or Cat6e
specification of the Commercial Building Telecommunications Cabling
Standard, ANSI/TIA/EIA 568-B fitted with an RJ45 Module jack.
10/100BASE-TX Ports
The interconnect cabling for 10BASE-T Ethernet must conform to
Cat3, Cat4, Cat5 (or better) UTP cabling for distances up to 100
meters.
The interconnect cabling for 100BASE-TX Fast Ethernet must
conform to Cat5 (or better) UTP cabling for distances up to 100
meters.
100BASE-FX Ports
The interconnect cabling must conform to 50/125 or 62.5/125 micron
multimode fiber-optic cabling for distances up to 3 kilometers.