Figure 15: Semi-circular cuts on the pole part of the KT-147407-02 bracket
Callout
Description
1
Semi-circular cuts on the pole part of the KT-147407-02 bracket, used for
attaching the M6 hex-head screws.
2. Insert the 0.5 in. (12.7 mm) wide stainless-steel cable clamp through the long slots on the sides of
KT-147407-02 pole part.
3. Position and insert the ends of the cable clamps around the pole.
4. Tighten the clamp screws to a torque of 11 in-lbs.
Attach the Access Point to a Pole Using KT-147407-02 Pole Part and the
KT-150173-01 Extension Arm
Before You Begin
The access point can be mounted on a pole using the KT-147407-02 pole part and the KT-150173-01
extension arm.
The following hardware is required:
•
KT-147407-02 pole part
•
KT-150173-01 extension arm
•
Four M6 hex-head screws
•
Two M12 stainless-steel screws and nuts
•
Two 0.5 in. (12.7 mm) wide stainless-steel cable clamps
•
Access point
About This Task
To install the access point on a pole:
Attach the Access Point to a Pole Using KT-147407-02
Pole Part and the KT-150173-01 Extension Arm
Install the Access Point
32
ExtremeWireless™ AP460i/e Access Points