Considerations Before Installing

The system is designed to operate in a typical Telco environment that is environmentally controlled. 
Choose an indoor area that has the following characteristics:

-

Temperature-controlled and humidity-controlled, to ensure that the maximum ambient room 
temperature shall not exceed the temperature specified in the product data sheet

-

Clean and free from airborne materials that can conduct electricity 

-

Well ventilated and away from sources of heat, including direct sunlight

-

Away from sources of vibration or physical shock

-

Isolated from strong electromagnetic fields produced by electrical devices

-

Secured, enclosed, and restricted-access, ensuring that only trained and qualified service 
personnel have access to the equipment

Establish at least 3 inches clearance on all sides for effective ventilation. Do not obstruct air intake 
vents or ventilation grills on the front, side, or rear panel. Locate the system away from heat sources. 

Make sure that your equipment is placed in an area that accommodates the product specifications 
for power consumption and component heat dissipation.

Make sure that your power supplies meet the site power or AC power requirements of all network 
equipment. 

Maintenance Safety

Use only original accessories or components that are approved for use with this system. 
Failure to follow these instructions may damage the equipment or violate required safety and 
EMC regulations. 

The chassis cover should be removed only by Extreme Networks personnel. This system contains no 
customer-serviceable components. Repairs to the system must be performed by an Extreme 
Networks factory service technician. 

Disconnect all power cords before working near power supplies, unless a maintenance procedure 
instructs you to do otherwise.

Replace a power cord immediately if it shows any signs of damage.

When you work with optical devices or other modular accessories, wear an ESD-preventive wrist 
strap to reduce the risk of electronic damage to the equipment. Connect the other end of the strap to 
an appropriate grounding point on the equipment rack. Leave the ESD-preventive wrist strap 
permanently attached to the equipment rack so that it is always available when you need to handle 
ESD-sensitive components.

Install all cables in a manner that avoids strain. Use tie wraps or other strain relief devices. 

Summary of Contents for 16519

Page 1: ...s suitable for the current rating of this product See Selecting AC Power Supply Cords on page 5 X440 Required Tools The following items are provided with the Summit X440 series switch Two rack mountin...

Page 2: ...ck Figure 2 Figure 2 Installing the Switch in the Rack 4 Insert and tighten rack mounting screws to secure the switch to the rack 5 Connect the power cable to the AC input power connector on the back...

Page 3: ...related installation manuals have the technical training and experience necessary to be aware of the hazards to which they are exposed in performing a task and are aware of measures to minimize the da...

Page 4: ...oduct specifications for power consumption and component heat dissipation Make sure that your power supplies meet the site power or AC power requirements of all network equipment Maintenance Safety Us...

Page 5: ...hannel Account Manager or Sales Manager or purchase a cord from your local supplier To locate a Sales Manager or Partner in your region visit http www extremenetworks com how to buy how to buy aspx Po...

Page 6: ...mmit X440 series switch Make sure that this connection is near the equipment and is easily accessible for quick disconnect WARNING Make sure that the source outlet is properly grounded according to th...

Page 7: ...lug see Figure 4 Figure 4 Attaching the Ground Wire to a Summit X440 DC Series Switch 3 Using a straight tip torque screwdriver tighten the retaining screw to 20 pound inches 2 25 Newton meters 4 Con...

Page 8: ...stem equipment LAN systems are designed only for intra building installations that is cable runs between devices must be in the same building as the connected units Fiber Optic Ports Optical Safety Th...

Page 9: ...smit LED laser through a magnifying device while the laser is powered on Never look directly at a fiber port on the switch or at the ends of a fiber cable when they are powered on Invisible laser radi...

Page 10: ...ServiceWatch Summit SummitStack Triumph Unified Access Architecture Unified Access RF Manager UniStack XNV the Extreme Networks logo the Alpine logo the BlackDiamond logo the Extreme Turbodrive logo t...

Reviews: