![Extraflame MIRKA User Manual Download Page 27](http://html1.mh-extra.com/html/extraflame/mirka/mirka_user-manual_2454237027.webp)
27
ENGLISH
FIrst load
this function allows the auger to be filled, thus facilitating first stove ignition phases, or in the event the pellet hopper is empty. with the
stove cold and "OFF", make sure the pellets have been introduced inside the hopper and activate the First LOaD function, confirming by
pressing OK.
To stop the continuous loading, simply press 1 for 3 seconds.
CONtrOLs PrOCeDure
Press key 6.
press key 3 until settiNgs appears and confirm by pressing key 6.
Keep pressing key 3 until First LOaD appears and confirm by pressing key 6.
use keys 4-5 to enable "ON" / disable "OFF"
Press key 1 several times to confirm and exit the menu.
reset
allows the user to reset all editable values to the default values.
CONtrOLs PrOCeDure
Press key 6.
Press key 3 until settiNgs appears and confirm by pressing key 6.
Keep pressing 3 until reset appears and confirm by pressing 6.
use keys 4-5 to enable "ON" / disable "OFF"
Press key 1 several times to confirm and exit the menu.
delta-t
this function allows the hysteresis thresholds to be set for stove ignition (DeLta-t ON) and switch-off (DeLta-t OFF), used as a room
temperature adjustment interval if not managed by an external thermostat
.
the possible values for
DELTA-T
go from:
0.5 - 5°C
CONtrOLs PrOCeDure
Press key 6.
Press key 3 until settiNgs appears and confirm by pressing key 6
Press key 3 until DeLta-t appears and confirm by pressing key 6.
use keys 4-5 to set the desired value.
Press key 6 to confirm and key 1 to scroll back through the menus until the initial page.
easy Control
the function allows for two values to be set:
OFF
(disabled - factory default)
ON
(enabled)
activation (easY CONtrOL = ON) is recommended in the event that there is an excessive formation of combustion residues in the flue during
operation at reduced power (see FLue exHaust chapter).
Caution! It is advisable to activate the easy Control function under the supervision of a qualified technician.
CONtrOLs PrOCeDure
Press key 6.
Press key 3 until settiNgs appears and confirm by pressing key 6.
Keep pressing 3 until
EASY CONTROL
appears and confirm by pressing 6.
use keys 4-5 to enable "ON" / disable "OFF"
Press key 1 several times to confirm and exit the menu.