ENGLISH
Displays
Display
Reason
off
Generator off
sTaRT
The START phase is in progress
pelleT loaDinG
Continuous pellet loading is in progress during the ignition phase
iGniTion
The ignition phase is in progress
pRepaRaTion
The preparation phase is in progress
WoRk
The normal work phase is in progress
MoDulaTion
The generator is operating at the minimum speed
final cleaninG
The final cleaning is in progress
sTanD-by
Generator off waiting to turn back on due to the thermostat.
coolinG
sTanD by
A new ignition is attempted when the generator has just be switched off. When the generator is switched off, it is
necessary to wait for the fumes motor to switch off completely, then clean the burn pot. Only after performing these
operations will it be possible to switch the generator on again.
black ouT
sTanD by
The generator is cooling down after a power failure.
After the cooling phase, it will turn back on automatically
auTo bloW
The automatic blow is active
alaRMs
Display
eXplanaTion
soluTion
Indicates the presence of an alarm.
On: indicates the presence of an alarm
The alarm can be reset only if the fumes motor has stopped and 15
minutes have passed since the alarm was displayed, by pressing key 1
for 3 seconds.
fuMes MoToR
faulT
Fumes motor failure
Contact the service centre
fuMes pRobe
Fumes probe fault.
Contact the service centre
HoT fuMes
High exhaust temperature
Check pellet loading (see "Easy setup"); if the problem is not solved,
contact a qualified technician.
no
iGniTion
The pellet hopper is empty.
Unsuitable pellet loading calibration.
Thermostat bulbs tripped.
Check for the presence of pellets in the hopper.
Adjust the pellet flow (see “Easy setup”).
Check the procedures described in the "Ignition" chapter.
Check the thermostats with bulbs (see chapter on Resetting)
no flaMe
The pellet hopper is empty.
Pellets not loading.
The gear motor is not loading pellets.
Check for the presence of pellets in the hopper.
Adjust the pellet flow (see “Easy setup”).
DepR alaRM
The door is not closed properly.
The ash drawer is not closed properly.
The combustion chamber is dirty.
The fumes exhaust pipe is blocked/dirty
Check that the door closes hermetically.
Check that the ash drawer closes hermetically.
Make sure that the fumes pipe and the combustion chamber are clean.
no
iGniTion - black ouT
No power during the ignition phase.
Turn the stove off by pressing key 1 and repeat the procedures
described in the "Ignition" chapter.
Other restoration operations must be performed by an authorised
technician.
alaRM
coMManD auGeR
Abnormal operation of pellet loading.
Contact the service centre