ADDITIONAl THeRmOsTAT fOR DUCTING mOTOR CONTROl
For models with ducting motor there is also the possibility of thermostatting the motor itself. The connection of an external
thermostat will allow to control the ducting motor independently from stove functioning.
At this point just set the desired temperature on the thermostat; the thermostat will control the functioning of the second
motor:
with temperature to be reached (closed contact) the second
motor will follow the trend of the stove.
when the temperature has been reached (open contact), it takes the
ducting motor to 1st speed and will be
displayed by the flashing LEd relating to the ducting
motor.
The ducting thermostat clamp is fitted with a jumper as standard.
See the example drawing to the side.
ReARms
The figures below illustrate the positions of the tank (85°c) rearms. contact the qualified technician if one of the rearms should
be triggered, so as to verify the cause.