Page 1: ...1 DIADEMA LILIANA IDRO idro USER MANUAL ENGLISH INGLESE ...

Page 2: ...2 ...

Page 3: ...essel system 6 Distances of safety devices according to the Standard 6 Type of system 7 Closed vessel plant 7 Safety valves 7 Closed expansion vessel 8 Commissioning checks 8 Automatic thermostatic mixer valve mandatory 8 Liliana idro Diadema idro basic hydraulic system diagram 9 Stove positioning 10 REARMS 10 FEATURES 10 devices 11 REFERENCE STANDARDS 11 General 12 INSTALLATION 13 Fumes exhaust s...

Page 4: ...l room thermostat 26 Additional thermostat functioning with stby active 26 Additional thermostat functioning with stby deactivated 26 aux 26 Menu structure 27 Set power 28 Set temperature 28 Set adjustments 28 Burn pot cleaning 28 stand by 28 Enable chrono 29 PELLET ADJUSTMENT 29 user menu 29 set clock 29 Chrono 30 Adjusting language 31 Display 31 reset 32 Other functions 32 Air discharge 32 FIRST...

Page 5: ...dvised to position the power supply cable so that it does not come into contact with hot parts of the appliance The power supply plug must be accessible after installation Do not close or reduce the dimensions of the airing vents in the place of installation The airing vents are essential for correct combustion Do not leave the packaging elements within reach of children or unassisted disabled per...

Page 6: ...I 10412 2 2009 Standard in force in Italy the closed systems must have safety valve pump control thermostat acousticalarmactivationthermostat temperatureindicator pressureindicator acousticalarm regulationautomatic circuit breaker switch automatic circuit breaker block switch block thermostat circulation system expansion system safety dissipation system incorporated with the generator with thermal...

Page 7: ... system with transfer pump and membrane impermeable to the passage of gases Expansion system without diaphragm Generality The closed systems must have Safety valve Pump control thermostat Acoustic alarm activation thermostat Temperature indicator Pressure indicator Acoustic alarm Adjustment automatic circuit breaker switch Automatic circuit breaker switch block thermostat Circulation system Expans...

Page 8: ...on vessel or plant expansion vessels unit altogether dimensioned for the total volume of water contained in the same plant or the same independent circuit Where it is necessary to separate the individual heat generator from the expansion vessel or expansion vessels unit a three way tap must be applied on the connection piping between the generator and the vessel in order to ensure in every positio...

Page 9: ... output 1 T3 Boiler return inlet 1 M Pressure Gauge T Thermometer G Filling system S Safety valve discharge SI System exhaust VB Balance valve VMTA Thermostatic mixer valve 55 C VMS Domestic hot water mixing valve It is recommended to consult the templates manual at for further information relative to the hydraulic connections air intake flue exhaust and dimension specifications of the product in ...

Page 10: ...r content of the thermo product heat exchanger l 21 Volume of expansion vessel integrated in the thermo product l 8 3 bar safety valve integrated in the thermo product SI Minimum and maximum pressure switch integrated into the thermo product SI Pump integrated into the thermo product SI Pump max head m 5 Envision a possible additional expansion vessel depending on the system water content REARMS T...

Page 11: ...operation with closed combustion chamber Forced draught appliance Appliance with ventilation in the fumes circuit and combustion with fumes flow at a positive pressure with respect to the environment Chimney Structure consisting in one or several walls containing one or several outflow airways The purpose of this predominantly vertical element is to expel the combustion products at a convenient he...

Page 12: ...nyrestrictionsrequiredbylocaladministrativeregulations specialorconventional requirements resulting from condominium regulations constraints laws or administration deeds must precede any other assembly or installation operation One must especially verify the suitability of the installation premises of the appliances already installed in the installation premises and in the adjacent and adjoining p...

Page 13: ...or sealed or closed hearth appliances with ducted combustion air taken from the outside Installation premises requirements The support surfaces and or points must have a suitable load bearing capacity to support the weight of the appliance of the accessories and coatings The adjacent side and rear walls and the supporting surface must be made of non combustible material Installation near combustib...

Page 14: ...ust discharged above the roof Direct discharge from the wall or towards closed spaces is forbidden even with clear skies In particular it is forbidden to use flexible and extendible metal pipes The chimney should only receive the exhaust of the smoke duct connected to the appliance collective flues or conveying exhausts from hoods above cooking appliances of any kind or exhausts from other generat...

Page 15: ...al pipes to connect the appliance to the chimney is not allowed nominal diameter distance from combustible materials indicated in millimetres followed by the arrow and flame symbol installer data and date of installation Every time one must cross combustible materials the following indications must be complied with Symbol Description Quota mm b Minimum distance of combustible materials from the in...

Page 16: ... fumes expulsion For the heat generator appliances equipped with electric fan for expelling fumes the instructions below must be followed The horizontal sections must have a minimum upward slope of 3 The length of the horizontal section must be minimal and in any case no longer than 3 metres The number of direction changes including the one due to the use of the T element must not be more than 4 A...

Page 17: ... of operating in damp conditions a device for reflux drainage condensation rainwater Ducted system A ducted system can be installed with one or more ducts operating only with negative pressure with respect to the environment The flexible hose compliant with UNI EN 1856 2 with T400 G characteristics meets the requirements Chimney caps The chimney caps must meet the following requirements they must ...

Page 18: ...he restoration of the initial conditions by replacing the gaskets and damaged items and cleaning those remaining in use Ignition tests Operation of the appliance must be verified with an ignition test i e for mechanical feed appliances one must complete the ignition test verify proper operation for at least the next 15 minutes and adjust the switch off For appliances installed in a hot water heati...

Page 19: ...of appliance installed 15kW 15 35 kW Pellet operated appliance 1 year 1 year Water operated appliances closed fireplaces thermo stoves thermo kitchens 1 year 1 year Boilers 1 year 1 year Fumes exhaust system 4 t of fuel used 4 t of fuel used For further details refer to the cleaning and maintenance chapter Inspection and maintenance report At the end of the inspection and or maintenance operations...

Page 20: ... of seasoning the calorific value of pellets is 5 kWh kg Pellet density is 650kg m3 and the water content is equal to 8 of its weight For this reason they do not require seasoning in order to arrive at a sufficiently adequate degree of heat yield THE USE OF EXPIRED PELLETS OR ANY OTHER MATERIAL WILL AFFECT THE FUNCTIONALITY OF YOUR GENERATOR AND MAY LEAD TO THE TERMINATION OF THE WARRANTY AND CESS...

Page 21: ... STBY function is activated Flashing with contact open the contact of the external additional thermostat is open and the STBY function is activated It indicates functioning of the fumes motor Off flue gas motor deactivated On flue gas motor active Flashing breakdown contact technical after sales service It indicates the summer winter function with an additional board Off Activates the winter funct...

Page 22: ...d in compliance with the guidelines of the regulations and the manual The tank must be full of pellets The combustion chamber must be clean The burn pot must be completely free and clean Check the hermetic closure of the fire door and the ash drawer Check that the power supply cable is connected correctly Thebipolarswitchintherearrightpartmustbepositioned on 1 Set temperature Set adjustments Statu...

Page 23: ...ogram or display and returns to the main menu without saving the data 11 Back The key returns to the display of the various menus 12 Confirmation key This key confirms the adjustments made during the user menu programming phase 13 Forward The key moves forward in the various menus 14 Enable F1 function Pre set key for future applications 15 Decrease The key decreases the value to be set 16 Stove s...

Page 24: ... preferred language to display the various messages Controls procedure Press key 6 and set power will appear Press key 2 several times until user menu is displayed Confirm using key 6 set clock will appear Press key 2 until set Language appears Confirm using key 6 Select the language using key 4 or 5 Press key 1 several times to confirm and exit the menu set language Language Italian English Germa...

Page 25: ...d to make product functioning homogenous preventing overheating blocks Normally this area is defined Safety zone Burn pot cleaning At pre set intervals the stove performs burn pot cleaning switching the machine off When the cleaning phase is finished the stove will re start automatically and continue its work going back to the selected power level MODULATION and H OFF As the water temperature appr...

Page 26: ... the water inside the stove and relative factory setting restrictions If the stove is in H OFF water temperature reached any additional contact or thermostat request will be ignored Additional thermostat functioning with stby deactivated When the STBY function is deactivated the LED is fixed When the contact or external thermostat is satisfied open contact temperature reached the stove will go to ...

Page 27: ...me 2nd switch off Monday prg2 off Sunday prg2 off ON OFF Ignition switch off consents for various days Set prg2 65 80 C Setting room temperature for the 2nd time slot Start prg3 00 10 OFF 00 00 Time 3rd ignition Stop prg3 00 10 OFF 00 00 Time 3rd switch off Monday prg3 off Sunday prg3 off ON OFF Ignition switch off consents for various days Set prg3 65 80 C Setting room temperature for the 3rd tim...

Page 28: ...to the initial status stand by The Stby function is used if immediate stove switch off or modulation via an additional thermostat is desired Controls procedure Press key 6 and set power will appear Press key 2 several times until set adjustments is displayed Press key 6 stand by will appear Use keys 4 5 to select enable ON disable OFF Press key 6 to confirm and key 1 to return to the previous menu...

Page 29: ...ke due to the excessive pellet feed as it is only burned partially The adjustment to be performed is in percentage Therefore a modification of this parameter will lead to a proportional variation of all stove feeding speeds Feeding is from 30 to 20 user menu set clock see chapter commissioning settings Controls procedure Press key 6 and set power will appear Press key 2 several times until set adj...

Page 30: ...utton 3 to go back to the previous parameter Stop prg1 off Stop prg1 12 00 Press key 6 to confirm SET CLOCK will appear Press key 2 until SET CHRONO appears SET CHRONO Enabling the 1st time slot days To enable on disable OFF the days use keys 4 and 5 Keys 2 and 3 to scroll the various days select from Monday to Friday on ON excluding Saturday and Sunday OFF To confirm and proceed press key 6 Monda...

Page 31: ...and Sunday by setting them at ON J To enable the chrono follow the instructions as described in the enable chrono chapter When the weekly Programmer is active the relevant icon will light up on the control panel Adjusting language see chapter commissioning settings Display The Display menu contains two sub menus Key lock Brightness Key lock The menu allows to lock the display keys like mobile phon...

Page 32: ...Confirm using key 6 Press key 2 until reset appears Confirm using key 6 Press keys 4 5 to select ON and press key 6 done will appear on the display to confirm Set H2o 75 C SET POWER 5 ENABLE CHRONO OFF START PRG1 OFF STOP PRG1 OFF MONDAY PRG1 OFF all chrono parameters OFF PELLET 00 BURN POT CLEANING 00 STAND BY OFF Other functions Air discharge This function allows to bleed any air in the stove On...

Page 33: ...NED AND CHECKED BY SPECIALISED PERSONNEL EVERY YEAR Daily cleaning to be carried out by the user Daily cleaning must be carried out by the generator s user with the utmost care after reading the instructions related to the procedures that need to be carried out later described in this manual The images are for illustration purposes Burn pot Remove the burn pot from the relevant compartment and fre...

Page 34: ...emove the ash in the combustion chamber at least once a week using a suitable vacuum cleaner MONTHLY Cleaning the deflector The fumes deflector located in the upper part of the combustion chamber must be removed on a monthly basis see figure to the side To remove it simply pull out the central fumes deflector as if it were a drawer 34 ...

Page 35: ...must be completely clear to ensure proper combustion See chapter cleaning under user s responsibility one can use the Pellet feed adjustment function to adjust the combustion according to the described requirements If the alarm persists and the above listed conditions have been checked contactthe qualified after sales assistance centre BURN POT HOLES Routine maintenance Some images could be offset...

Page 36: ... them and apply silicone where envisioned C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Feed box complete emptying and cleaning E Room air fan disassembly and removal of dust and debris of any pellets F Check air intake pipe and cleaning of the flow sensor Routine maintenance Some images could be offset from the original model 36 ...

Page 37: ...it for the complete shutdown of the fumes motor then clean the burn pot The stove can only be re ignited when these operations have been performed Hoff Stove off due to water temperature over set As soon as the water temperature drops below the pre set parameters the stove will switch back on T OFF Stove off waiting for re ignition as all the requests have been satisfied Stand by Black out The sto...

Page 38: ...feed pellets Check for the presence of pellets in the feed box Adjust the pellet flow see Pellet feed adjustment Depr alarm The door is not closed correctly The ash drawer is not closed correctly The combustion chamber is dirty The flue exhaust pipe is blocked Check hermetic door closure Check hermetic closure of the ash drawer Check cleanliness of the fumes pipe and the combustion chamber Debimet...

Page 39: ...ENGLISH ...

Page 40: ... info Extraflame it www lanordica Extraflame com 004276005_MU_DIADEMA_LILIANA_IDRO_002 The Manufacturer reserves the right to vary the features and data shown in this booklet at any time and without prior notice in order to improve its products This manual cannot be considered as a contract for third parties ...