ENGLISH
alaRMs
Display
eXplanaTion
soluTion
Indicates the presence of an alarm.
On: indicates the presence of an alarm
Flashing: indicates the deactivation of the depression
sensor.
The alarm can be reset by pressing key 1 for 3 seconds only
if the fumes motor has stopped and if 15 minutes have
elapsed from when the alarm was displayed.
aspiRaTion faulT
Fumes motor fault
Contact after-sales centre
fuMes pRoBe
Fumes probe failure.
Contact after-sales centre
HoT fuMes
High flue gas temperature
Check pellet feed (see “Pellet feed adjustment”). If the
problem cannot be solved, contact an authorised technician.
clean cHeck up 1 - 2
(1 = in sTaRT-up sTaGe)
(2= in opeRaTinG sTaGe)
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The flue exhaust pipe is blocked.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe, of the sensor in the
primary air channel and the combustion chamber.
no
iGniTion
The pellet feed-box is empty.
Pellet feed calibration inadequate.
Check for the presence of pellets in the feed-box.
Adjust pellet flow (see “Pellet feed adjustment”).
Check the procedures described in the “Ignition” chapter.
no iGniTion
Black ouT
No current during the ignition phase.
Take the stove to OFF conditions using key 1 and repeat
the procedure described in the "Ignition" chapter.
no pelleTs
The pellet feed-box is empty.
No pellet feed.
The motor reducer does not feed pellets.
Check for the presence of pellets in the feed-box.
Adjust the pellet flow (see “Pellet feed adjustment”).
DepR alaRM
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The flue exhaust pipe is blocked
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion
chamber.
DeBiMeTeR
faulT
Flow sensor faulty.
Sensor disconnected
Contact after-sales centre
H20 oveRTeMp
Air in the system
Unsuitable circulation
Possible air in the system, vent the system.
Lack of adequate circulation.
Lack of or inadequate safety zone.
The water in the stove has exceeded 95°C.
Possible circulator anomaly.
If the problem persists, the reset operations must be
carried out by an authorised technician.
TRapDooR faulTy
Door not closed properly
Burn pot dirty or clogged
Check closure of the door.
Check that the burn pot is clear and clean.
The automatic burn pot cleaning is blocked.
If the problem persists contact the service centre
alaRM
MiniMuM pRessuRe
The system pressure read by the pressure
switch is too low.
Possible air in the system, vent the system.
Possible lack of water or leaks due to anomalies in some
system component.
If the problem persists contact the service centre
alaRM
H2o pRoBe
H2O probe failure
Contact after-sales centre
alaRM
MaX H2o pRessuRe
The pressure of the water has exceeded
the max threshold
Possible air in the system, vent the system.
Check that the expansion vessels are not damaged or
under-dimensioned
Check that the cold system is loaded at the correct pressure
If the problem persists contact the service centre
38