37
A
TTENTION!
1. The cover of the pellet container must always be kept closed except when loading
fuel.
2. The sacks of pellets must be kept at least 1.5 metres away from the stove.
3. The hopper should always be kept at least half full.
4. Before refilling, make sure that the appliance is switched off.
12.2 DIVINA PLUS operation
The operation of the DIVINA PLUS model is the same as that of the other models; in addition, it
has a second motor for heat distribution. During normal operation, the second fan follows the
operation of the first one.
It is possible to enable/disenable the operation of the second motor and increase/decrease its
ventilation at a percentage rate.
12.3 Shutdown
Pr
ess button
1
for thr
ee seconds
.
When the three seconds have elapsed, the stove automatically starts the shutdown stage, cutting
off the pellet feed. Display
D1
shows the message “
of
f
”, the current time, and the room
temperature in alternation.
Both the exhaust motor and warm air ventilation motor continue to run until the stove temperature
has dropped sufficiently.
12.4 Remote control
The heat setting
, the room temperature, and automatic start/stop of the stove can be remote
controlled.
Correspondence between remote control
buttons and display buttons
1
= B3+B5
2
= B2
3
= B3
4
= B4
5
= B5
P3
P4
P2
P5