32
ENGLISH
Readings
display
Reason
off
Generator off
sTaRT
The start-up phase is in progress
pelleT loading
Continuous pellet loading is in progress during the ignition phase
igniTion
The ignition phase is in progress
pRepaRaTion
The preparation phase is in progress
WoRk
The normal work phase is in progress
ModulaTion
The generator is working at minimum level
final cleaning
The final cleaning is in progress
sTand-by
Generator off waiting for re-ignition due to the thermostat.
cooling
sTand-by
A new ignition is attempted when the generator has just been switched off. When the generator switches off, wait for
the fumes motor to completely shut down, then clean the burn pot. The generator can only be re-ignited after these
operations have been performed.
black ouT
sTand-by
The generator is cooling down after a power cut.
Once cooling is complete it will automatically re-start
auTo bloW
Automatic blowing is active
seRvice
When this message appears, contact the technician authorised to perform routine maintenance on the appliance. If
cleaning is not performed, the message will appear at every start-up without interrupting normal stove operation.
alaRMs
display
eXplanaTion
soluTion
Indicates the presence of an alarm.
On: indicates the presence of an alarm.
The alarm can only be reset if the fumes motor has stopped and 15
minutes have passed since the alarm was displayed, by pressing key 1
for 3 seconds.
fuMes MoToR
faulT
Fumes motor fault
Contact after-sales service
fuMes pRobe
Fumes probe fault.
Contact after-sales service
HoT fuMes
High fumes temperature
Check pellet loading (see “Easy setup”). If the problem cannot be
solved, contact an authorised technician.
no
igniTion
The pellet hopper is empty.
Pellet loading calibration inadequate.
Thermostat bulbs tripped.
Check for the presence of pellets in the hopper.
Adjust the pellet flow (see “Easy setup”).
Check the procedures described in the “Ignition” chapter.
Check the bulb thermostats (see chapter on Rearming)
no flaMe
The pellet hopper is empty.
No pellet loading.
The gear motor does not load pellets.
Check for the presence of pellets in the hopper.
Adjust the pellet flow (see “Easy setup”).
depR alaRM
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The fumes exhaust pipe is blocked/dirty
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes exhaust pipe and the combustion
chamber.
no
igniTion - black ouT
No electrical current during the
ignition phase.
Place the stove into “off” mode using key 1 and repeat the steps
described in the “Ignition” chapter.
Other restoration steps must be performed
by an authorised technician.
coMMand augeR
alaRM
Abnormal pellet loading.
Contact after-sales centre